Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 29
  • Item
    Thumbnail Image
    Training place pitch perception in cochlear implant users [Abstract]
    Dawson, Pam ; Clark, Graeme M. ( 1997)
    The study has aimed at determining whether the ability to use place coded vowel formant information could be enhanced with analytical vowel training in a group of -congenitally deafened patients, who showed limited speech perception skills after cochlear implant experience ranging from 1y8m to 6y11m. It has investigated whether improvements in vowel perception after training can carry over to word recognition. A further objective was to see whether poorer vowel perception was associated with poorer electrode position difference limens. Three children, one adolescent and one young adult were assessed with synthesized versions of the words /hid, head, had, hud, hod, hood/ and a natural version of these words as well as with a closed-set monosyllabic word task. The change in performance after 10 training sessions was compared to the change in performance during a non-training period. Four of the five patients showed a significant gain in synthetic vowel perception post-training on at least one assessment, but only two patients showed gains across a number of tests post-training. For one of these 2 children improvements in vowel perception generalized to word perception. Patients’ electrode limens ranged from 1 to 3 electrodes except for 1 adolescent whose minimal progress post-training could be partly explained by poorer apical electrode discrimination. The findings are discussed with reference to a number of factors, including the notion of a "critical period" for neural plasticity.
  • Item
    Thumbnail Image
    Post-implant habilitation for children using cochlear implants: effects on long-term outcome
    Dowell, Richard C. ; Dettman, Shani J. ; WILLIAMS, SARAH ; TOMOV, ALEXANDRA ; Hollow, Rod ; Clark, Graeme M. ( 2002)
    Most clinicians working in the cochlear implant field advocate a regular habilitation program for young children receiving implants. The development of auditory skills and the incorporation of these skills into language development are thought to be key areas for such programs. Studies of speech perception and language outcomes demonstrate that an educational approach that emphasises spoken language development appears to enhance the results for implanted children. It remains difficult, however, to demonstrate clearly the effect of habilitation objectively and to determine how much individual attention is desirable for each child. This pilot study considered the long term speech perception and language outcomes for two groups of children who received Nucleus cochlear implants in Melbourne. One group (n=17) was identified as receiving regular habilitation from the Melbourne Cochlear Implant Clinic over a four year post-operative period. Another group (n=l1) was identified as receiving very little regular habilitation over the post-operative period. The language and speech perception results for these two groups showed a significant difference in performance on a wide range of measures with the group receiving regular formal habilitation demonstrating better performance on all measures. These groups included only congenitally, profoundly hearing-impaired children and did not differ significantly on mean age at implant or experience at the time of assessment. Further studies are needed to clarify these results on a larger group of children, and to control for additional confounding variables. Nonetheless, these preliminary results provide support for the incorporation of regular long-term habilitation into cochlear implant programs for children.
  • Item
    Thumbnail Image
    Predicting speech perception outcomes for children using multichannel cochlear implants [Abstract]
    Dowell, Richard C. ; Dettman, Shani J. ; WILLIAMS, SARAH ; Hill, Katie ; TOMOV, ALEXANDRA ; Clark, Graeme M. ( 2002)
    The ability to predict outcomes for children who are cochlear implant candidates is most helpful in counselling families and making clinical recommendations. Open-set speech perception results have been collected for all children implanted with the Nucleus device in Melbourne. Speech perception as assessed at six month intervals following implantation. Information wascollected for each child regarding type of hearing loss, duration and age at onset of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech coding scheme and implant experience.
  • Item
    Thumbnail Image
    Physiological and histopathological effects of chronic monopolar high rate stimulation on the auditory nerve
    TYKOCINSKI, MICHAEL ; Linahan, N. ; Shepherd, R. K. ; Clark, Graeme M. ( 2000)
    Speech processing strategies based on high rate electrical stimulation have been associated with improvements in speech perception among cochlear implant users. The present study was designed to evaluate the electrophysiological and histopathological effects of long-term intracochlear monopolar stimulation at the maximum stimulus rate of the current Nucleus Cochlear implant system (14493 pulses/s) as part of our ongoing investigations of safety issues associated with cochlear implants
  • Item
    Thumbnail Image
    Pre-operative hearing assessment in young cochlear implant candidates
    RANCE, GARY ; Dowell, Richard C. ; Rickards, Field W. ; Clark, Graeme M. ( 2000)
    Early implantation of congenitally deaf candidates is now a goal of most cochlear implant clinics. This objective can only be achieved through the use of audiological tests that are able to identify and quantify hearing loss in infancy. Behavioural conditioning techniques provide the most accurate indication of hearing acuity in older subjects, but these procedures are unreliable in young (6 months) or developmentally delayed children. This paper investigates the degree of accuracy with which two electrophysiological test techniques (click-ABR & steady-state evoked potential [SSEPD can be used to assess auditory function in infants with significant hearing loss. ABR and SSEP findings from 108 children were compared with hearing levels obtained behaviourally.
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.
  • Item
    Thumbnail Image
    Application of the cochlear implant to profoundly hearing impaired adolescents: re-visiting the inclusion criterion for older children
    DETTMAN, SHANI ; Latus, Katie ; Cosson, Liz ; Dowell, Richard C. ; Clark, Graeme M. ( 2000)
    Objective: The purpose of this study is to examine the range of outcomes for older children receiving the multi-channel cochlear implant. Recent improvements in the speech perception performance for profoundly hearing impaired children and adults have lead to expanded selection criterion for cochlear implant inclusion. That is, the efficacy of cochlear implants for adults with acquired hearing loss is well documented. In addition, the application of the cochlear implant to young children has lead to improvements in open set speech perception, speech production and language acquisition. In contrast, congenitally deaf and prelingually deafened children who are implanted after the age of 8 years have performed poorer than children implanted at a younger age on speech perception, speech production and psychophysical performance measures.
  • Item
    Thumbnail Image
    Speech perception in noise with cochlear implant and hearing aid for implanted adolescents
    DETTMAN, SHANI ; Latus, Katie ; Cosson, Liz ; Dowell, Richard C. ; Clark, Graeme M. ( 2000)
    Objective. To describe the open set speech perception performance for 8 congenitally deaf adolescents who use a multichannel cochlear implant and behind-the ear hearing aid as their 'everyday listening' condition. Expanded indication for cochlear implant inclusion has lead to the implantation of a number of persons with severe to profound hearing loss. It has been suggested that persons who have some residual bearing are good candidates for the cochlear implant due to: the presence of more ganglion cells, prior auditory experience, pre-patterning of the auditory cortex or other factors, as yet unknown, such as language experience.
  • Item
    Thumbnail Image
    Auditory processing abilities in children using cochlear implants: their relevance to speech perception [Abstract]
    Dawson, Pam W. ; McKay, Colette M. ; Busby, Peter A. ; Grayden, David B. ; Clark, Graeme M. ( 1999)
    This study aimed to investigate the relationships between some basic auditory processing skills, subject variables and speech perception ability in young children using cochlear implants. A modification of the play audiometry procedure was used to measure electrode discrimination and "rate-of-processing" ability in seventeen 4-10 year old children. In the electrode discrimination task, children responded with a game-like motor response when a repeating stimulation on a reference electrode "changed" to a different electrode. In the "rate-of processing" task, children had to respond to the "change" to a different electrode, when the duration of the stimuli and the time interval between the stimuli were decreased. Normally hearing children were assessed on this task with acoustic stimulation. Nonverbal intelligence, speech feature discrimination and closed-set word recognition were also measured in the children using implants.
  • Item
    Thumbnail Image
    The use of click-ABR and steady state evoked potentials for hearing assessment in young cochlear implant candidates [Abstract]
    Rance, G. ; Dowell, Richard, C. ; Richards, F. W. ; Clark, Graeme M. ( 1997)
    The accurate assessment of hearing thresholds in prospective cochlear implant candidates is essential. As the minimum age of implantation has reduced, audiologists have been faced with the complicated task of obtaining precise audiometric information in children whose immaturity may severely restrict the assessment process. Clearly for these young candidates, there is a place for a reliable, objective measure of residual hearing in the pre-operative test battery. This paper examines the degree of accuracy with which the click-ABR and the steady-state evoked potential (SSEP) techniques can provide estimates of hearing level in subjects with several profound hearing loss.