Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 25
  • Item
    Thumbnail Image
    Optimizing dynamic range in children using the nucleus cochlear implant
    Dawson, PW ; Decker, JA ; Psarros, CE (LIPPINCOTT WILLIAMS & WILKINS, 2004-06)
    OBJECTIVE: The aim of this study was to investigate the benefits of the preprocessing scheme "Adaptive Dynamic Range Optimization" (ADRO) in children using Nucleus cochlear implants. Previous research with adults indicates improved speech perception in quiet and improved sound quality in everyday listening environments with the ADRO scheme. DESIGN: Children were given 4 wk of take-home experience with ADRO, with a minimum of 2 wk in which ADRO was "locked-in." After 1 wk of ADRO use and again after 4 wk of ADRO use, Bench-Kowal-Bamford (BKB) sentence perception in quiet at a low input level of 50 dB SPL (unweighted root mean square) and sentence perception in noise were compared with the child's everyday (Standard) program and the ADRO program. Children also rated the loudness of a variety of environmental sounds and indicated which program provided the best hearing in a variety of everyday listening situations. RESULTS: On average, BKB sentence perception in quiet at 50 dB SPL was significantly better with the ADRO program compared with the Standard program. The group mean improvement was 8.60%. Similarly, group mean scores for BKB sentences presented at 65 dB SPL in multitalker babble were significantly higher with the ADRO program (an improvement of 6.87%). The ADRO program was the preferred program in 46% of the listening situations, whereas the Standard program was preferred in 26% of situations. Everyday sounds were not unacceptably loud with ADRO. CONCLUSIONS: There was an ADRO benefit for this group of children in quiet and in noise. These findings suggest that young children would benefit from the ADRO programming option being locked in along with other processor settings in the SPrint processor once their MAP levels have stabilized. Some older children and teenagers may choose to use ADRO selectively for specific listening situations.
  • Item
    Thumbnail Image
    Electrode discrimination by early-deafened subjects using the Cochlear Limited multiple electrode cochlear implant
    Busby, P. A. ; Clark, Graeme M. ( 2000)
    Objective: The aims of this study were to determine whether electrode discrimination by early-deafened subjects using the Cochlear Limited prosthesis varied at different locations on the electrode array, was influenced by the effects of auditory deprivation and experience with electric stimulation, and was related to speech perception. Design: Difference limens for electrode discrimination were measured in 16 early-deafened subjects at three positions on the array: electrodes 18 (apical), 14 (mid), and 8 (basal). Electrodes were stimulated using random variations in current level to minimize the influence of loudness cues. Assessed were correlations between the difference limens, subject variables related to auditory deprivation (age at onset of deafness, duration of deafness, and age at implantation) and auditory experience (duration of implant use and the total time period of auditory experience), and speech perception scores from two closed-set and two open-set tests. Results: The average difference limens across the three positions were less than two electrodes for 75%, of subjects, with average limens between 2 and 6.5 electrodes for the remaining 25% of subjects. Significant differences across the three positions were found for 69% of subjects. The average limens and those at the basal position positively correlated with variables related to auditory deprivation, with larger limens for subjects implanted at a later age and with a longer duration of deafness. The average limens and those at the apical position negatively correlated with closed-set speech perception scores, with lower scores for subjects with larger limens, but not with open-set scores. Speech scores also negatively correlated with variables related to auditory deprivation. Conclusions: These findings showed that early-deafened subjects were generally successful in electrode discrimination although performance varied across the array for over half the subjects. Discrimination performance was influenced by the effects of auditory deprivation, and both electrode discrimination and variables related to auditory deprivation influenced closed-set speech perception.
  • Item
    Thumbnail Image
    Threshold shift: effects of cochlear implantation on the risk of pneumococcal meningitis
    Wei, Benjamin P. C. ; Shepherd, Robert K. ; Robins-Browne, Roy M. ; Clark, Graeme M. ; O'Leary, Stephen J. ( 2007)
    Unavailable due to copyright.
  • Item
    Thumbnail Image
    Effects of inner ear trauma on the risk of pneumococcal meningitis
    Wei, Benjamin P. C. ; Shepherd, Robert K. ; Robins-Browne, Roy M. ; Clark, Graeme M. ; O'LEARY, STEPHEN ( 2007)
    Objective: To examine the risk of pneumococcal meningitis in healthy rats that received a severe surgical trauma to the modiolus and osseous spiral lamina or the standard insertion technique for acute cochlear implantation. Design: Interventional animal studies. Subjects: Fifty-four otologically normal adult Hooded- Wistar rats. Interventions: Fifty-four rats (18 of which received a cochleostomy alone; 18, a cochleostomy and acute cochlear implantation using standard surgical techniques; and 18, a cochleostomy followed by severe inner ear trauma) were infected 4 weeks after surgery with Streptococcus pneumoniae via 3 different routes (hematogenous, middle ear, and inner ear) to represent all potential routes of bacterial infection from the upper respiratory tract to the meninges in cochlear implant recipients with meningitis. Results: Severe trauma to the osseous spiral lamina and modiolus increased the risk of pneumococcal meningitis when the bacteria were given via the middle or inner ear (Fisher exact test, P<.05). However, the risk of meningitis did not change when the bacteria were given via the hematogenous route. Acute electrode insertion did not alter the risk of subsequent pneumococcal meningitis for any route of infection. Conclusions: Severe inner ear surgical trauma to the osseous spiral lamina and modiolus can increase the risk of pneumococcal meningitis. Therefore, every effort should be made to ensure that cochlear implant design and insertion technique cause minimal trauma to the bony structures of the inner ear to reduce the risk of pneumococcalmeningitis.
  • Item
    Thumbnail Image
    Assessment of the protective effect of pneumococcal vaccination in preventing meningitis after cochlear implantation
    Wei, Benjamin P. C. ; Robins-Browne, Roy M. ; Shepherd, Robert K. ; AZZOPARDI, KRISTY ; Clark, Graeme M. ; O'Leary, Stephen J. ( 2007)
    Objectives: To examine if a 23-valent pneumococcal capsular polysaccharide vaccine (PPV23) reduces the risk of meningitis in healthy rats after cochlear implantation. Design: Interventional animal study. Interventions: Thirty-six rats (18 immunized and 18 unimmunized) received cochlear implantations and were then infected with Streptococcus pneumoniae via 3 different routes (hematogenous, middle ear, and inner ear) in numbers sufficient to induce meningitis. Results: The rats with implants that received PPV23 were protected from meningitis when the bacteria were delivered via the hematogenous and middle-ear routes (Fisher exact test P<.05). However, the protective effect of the vaccine in the rats with implants was only moderate when the bacteria were inoculated directly into the inner ear. Conclusions: Our animal model clearly demonstrates that immunization can protect healthy rats with a cochlear implant from meningitis caused by a vaccine-covered serotype. This finding supports the notion that all current and future implant recipients should be vaccinated against S pneumoniae.
  • Item
    Thumbnail Image
    Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients
    Busby, P. A. ; Clark, Graeme M. ( 1997)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Cochlear implants in the third millennium
    Clark, Graeme M. ( 1999)
    This article discusses the specific challenges facing cochlear implantation in the Third Millennium.
  • Item
    Thumbnail Image
    Gap detection by early-deafened cochlear-implant subjects
    Busby, P. A. ; Clark, Graeme M. ( 1999)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli
    Shepherd, Robert K. ; Linahan, N. ; Xu, J. ; Clark, Graeme M. ; Araki, S. ( 1999)
    This study was designed to evaluate the pathophysiological response of the cochlea following long-term intracochlear electrical stimulation using a poorly charge-balanced stimulus regime, leading to direct current (DC) levels >0.1 µA. Four normal-hearing adult cats were bilaterally implanted with scala tympani electrode arrays and unilaterally stimulated for periods up to 2200 h. Stimuli consisted of 50 µs monophasic current pulses presented at 2000 pulses per second (pps) per channel, and resulted in DC levels of 0.4-2.8 µA. Both acoustic and electrical (EABR) evoked potentials were periodically recorded during the stimulation program. Frequency-specific stimuli indicated that an extensive and widespread hearing loss occurred over the 4-24 KHz region in all stimulated cochleae, although the 2 KHz region exhibited thresholds close to normal in some animals, despite long-term implantation and chronic stimulation. Longitudinal EABRs showed a statistically significant increase in threshold for three of the four animals. Histopathological evaluation of the cochleae revealed a highly significant reduction in ganglion cell density in stimulated cochleae compared with their controls. Spiral ganglion cell loss was significantly correlated with the degree of inflammation, duration of electrical stimulation, and the level of DC. In conclusion, the present study highlights the potential for neural damage following stimulation using poorly charge-balanced stimuli.
  • Item
    Thumbnail Image
    Research advances for cochlear implants
    Clark, Graeme M. ( 1998)
    Abstract not available due to copyright.