Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 20
  • Item
    Thumbnail Image
    Speech processing for a multiple-channel cochlear implant
    Tong, Y. C. ; Millar, J. B. ; Clark, Graeme M. ; Martin, L. F. ; Busby, P. A. ( 1980)
    A laboratory speech processor has been developed for a multiple-channel cochlear implant prosthesis. The speech processor accepts the speech waveform as an input and produces a pattern of electrical stimulus data as output. The electrical stimulus data are transmitted to the implanted receiver-stimulator by a transmitter which is external to the speech processor. Four speech signal parameters were estimated every 20 ms in the parameter estimation section of the speech processor. These parameters included the fundamental frequency (FO), a low frequency energy measure (AO) , the second formant frequency (F2) and its amplitude (A2).
  • Item
    Thumbnail Image
    Speech processing for a totally deaf patient with a multiple-electrode cochlear implant [Abstract]
    Clark, Graeme M. ; Tong, Y. C. ; Millar, J. B. ; Martin, L. F. ; Busby, P. A. ( 1980)
    A patient with a total hearing loss had a multiple-electrode cochlear implant performed on 1 August 1978 (Clark et. Al. 1979). Preliminary findings (Tong et al 1979) have shown that low and high pitch are discriminated on a place basis. Stimulating different electrodes produced the vowel colours.......
  • Item
    Thumbnail Image
    Improved sound processing for cochlear implants
    James, C.J. ; Just, Y. ; Knight, M.R. ; Martin, L.F.A. ; McKay, C.M. ; Plant, K.L. ; Tari, S. ; Vandali, A.E. ; Clark, Graeme M. ; Cowan, R.S.C. ; McDermott, H. J. ; Blamey, P. J. ; Dawson, P. ; Fearn, R. A. ; Grayden, D. B. ; Henshall, K. R. ( 2002)
    Four signal processing schemes currently under development aim to improve the perception of sounds/ especially speech, for children and adults using the Nucleus cochlear implant system. The schemes are (1) fast-acting input-signal compression, (2) Adaptive Dynamic Range Optimisation (ADRO), (3) TESM, a scheme that emphasises transients in signals, and (4) DRSP, a strategy that applies different stimulation rates to selected sets of electrodes.
  • Item
    Thumbnail Image
    Physiological and histopathological effects of chronic monopolar high rate stimulation on the auditory nerve
    TYKOCINSKI, MICHAEL ; Linahan, N. ; Shepherd, R. K. ; Clark, Graeme M. ( 2000)
    Speech processing strategies based on high rate electrical stimulation have been associated with improvements in speech perception among cochlear implant users. The present study was designed to evaluate the electrophysiological and histopathological effects of long-term intracochlear monopolar stimulation at the maximum stimulus rate of the current Nucleus Cochlear implant system (14493 pulses/s) as part of our ongoing investigations of safety issues associated with cochlear implants
  • Item
    Thumbnail Image
    Parameter selection and programming recommendations for the ACE and CIS speech processing strategies [Abstract]
    Plant, Kerrie L. ; Whitford, Lesley A. ; Psarros, C. E. ; Vandali, A. E. ; Clark, Graeme M. ( 1999)
    The Nucleus 24 Cochlear Implant system with the SPrint processor provides access to multiple speech processing strategies and a wide range of programming parameters. Strategy comparison studies have suggested that the optimal parameter set and coding strategy varies from individual to individual. It is necessary, however, to establish some default programming parameters and fitting guidelines. Therefore we have investigated the effect of stimulation rate and the number of channels or maxima in the ACE or CIS strategies, as well as the optimal programming strategy for subjects with a limited number of available electrodes. Speech perception was tested using monosyllabic words and sentences in noise, with the evaluation protocol designed to take into account learning effects. Take-home experience was provided with all programs, and subjects were asked to complete a comparative performance questionnaire regarding program preference. Six or eight subjects were enrolled in each study.
  • Item
    Thumbnail Image
    Physiological and histopathological effects of chronic monopolar high rate stimulation of the auditory nerve [Abstract]
    Tykocinski, M. ; Linahan, N. ; Shepherd, Robert K. ; Clark, Graeme M. ( 1999)
    Speech processing strategies based on high rate electrical stimulation have been associated with improvements in speech perception among cochlear implant users. The present study was designed to evaluate the electrophysiological and histopathological effects of long-term intracochlear monopolar stimulation at the maximum stimulus rate of the current Nucleus Cochlear implant system (14493 pulses/s) as part of our ongoing investigations of safety issues associated with cochlear implants.
  • Item
    Thumbnail Image
    An analysis of high rate speech processing strategies using the Nucleus 24 cochlear implant [Abstract]
    Vandali, A. E. ; Grayden, D. B. ; Whitford, L. A. ; Plant, K. L. ; Clark, Graeme M. ( 1998)
    The effects of varying the stimulation rate on speech perception was evaluated in five postlinguistically deaf adult users of the Nucleus 24 Cochlear Implant System. Three different rates of electrical stimulation, 250, 807, and 1615 pulses per second per channel were employed. For the high stimulus rate the analysis frequency was the same as for the medium rate condition. The study investigated the effect of varying rate of stimulation when using the electrode selection technique of the SPEAK strategy. The study used a repeated ABC experimental design, in order to account for learning effects and to minimize ordering effects. Speech perception was evaluated using both monosyllabic words (open-sets of CNC words in quiet) and sentence materials (open-sets of CUNY sentences at signal-to-noise ratios from +20 to 0dB). In addition, the subjects' perception of closed-sets of 19 vowels and 24 consonants, presented in the H/VID and A/C/A context, were also investigated. The recognition and perception of distinctive features were assessed across strategies and patients. Preliminary speech perception results have shown no statistically significant difference in performance between the low and medium stimulation rates. However, significantly poorer results were observed for the high rate condition for some tests with some individuals. Individual differences may be explained by the effects of rate of stimulation on speech features.
  • Item
    Thumbnail Image
    An analysis of high rate speech processing strategies using the Nucleus 24 cochlear implant [Abstract]
    Vandali, A. E. ; Grayden, D. B. ; Whitford, L. A. ; Plant, K. L. ; Clark, Graeme M. ( 1998)
    Speech comprehension for a group of five users of the Nucleus 24 Cochlear Implant system was explored at three rates of electrical stimulation, 250, 807, and 1615 pulses per second per channel. For the high stimulus rate the analysis frequency was the same as for the medium rate condition. The study investigated the effect of varying rate of stimulation when using the electrode selection technique of the SPEAK strategy. This has been undertaken using a repeated ABC experimental design to account for learning and minimize ordering effects. Speech perception was assessed using open-sets of CNC words in quiet and open-sets of CLTNY sentences at signal-to-noise ratios from +20 to 0dB. Closed-sets of 19 vowels and 24 consonants were also presented, in the H/V/D and A/C/A context. The recognition and perception of distinctive features were assessed across strategies and patients. Preliminary speech perception results have shown no statistically significant difference in performance between the low and medium stimulation rates. However, significantly poorer results were observed for the high rate condition for some tests. Individual differences may be explained by the effects of rate of stimulation on speech features.
  • Item
    Thumbnail Image
    Electrical stimulation of the auditory nerve: chronic monopolar stimulation using very high stimulus rates [Abstract]
    Tykocinski, M. ; Linahan, N. ; Shepherd, Robert K. ; Clark, Graeme M. ( 1998)
    Speech processing strategies based on high rate electrical stimulation have been associated with recent improvements of speech perception among cochlear implant users. In the present study we investigated the effects of chronic monopolar stimulation using very high rates (14493 pulses\s). Under general anaesthesia (ketamine (20 mg/kg) and xylazine (3.8 mg/kg) i.p.) six normal hearing cats were implanted bilaterally with a three channel platinum (Pt) scala tympani electrode array, while a return Pt-electrode was placed outside the bulla. Chronic electrical stimulation using charge-balanced biphasic current pulses was delivered unilaterally via a transcutaneous leadwire connected to a backpack-stimulator for up to 2000 h. The animals hearing status was periodically monitored using acoustically evoked compound action potentials (CAP's) and brainstem responses (ABR's). In addition the electrically evoked ABR (EABR) was also recorded to ensure that the chronic stimulus was above threshold. Stimulus current and electrode voltage waveforms were monitored twice daily and access resistance (Ra) and electrode impedance (Zc) calculated. ABR and CAP thresholds were elevated immediately following implantation, but generally showed evidence of partial recovery (0-40 dB). Further deterioration of thresholds on the stimulated side (10-30 dB) was subsequently observed, while control-thresholds remained more stable. Ra (1.3-1.8 kΩ) and Zc (2.2-3.8Ω) typically increased in the first few weeks of electrical stimulation up to Ra:5.6 kΩ and Zc:8.1 kΩ, before decreasing slightly to a constant plateau. These initial results indicate changes in the electrode-tissue interface and tissue growth within the cochlea. They also indicate that chronic stimulation at these high rates may decrease residual hearing.
  • Item
    Thumbnail Image
    Speech perception in implanted children: effects of preoperative residual hearing and speech processing strategy [Abstract]
    Meskin, T. ; Rance, G. ; Cody, K. ; Sarant, J. ; Larratt, M. ; Latus, K. ; HOLLOW, RODNEY ; Rehn, C. ; Dowell, R.C. ; Pyman, B. ; Gibson, W.P.R. ; Clark, Graeme M. ; Cowan, Robert S. C. ; Barker, E. J. ; Pegg, P. ; Dettman, S. ; Rennie, M. ; Galvin, K. ( 1997)
    Since the first child was implanted with the Nucleus 22-channel cochlear prosthesis in Melbourne in 1985, the number of implanted children world-wide has rapidly expanded. Over this period, more effective paediatric assessment and management procedures have developed, allowing cochlear implants to be offered to children under the age of 2 years. In addition, a succession of improved speech processing strategies have been implemented in the Nucleus implant system, resulting in increased mean speech perception benefits for implanted adults. Research in the Melbourne and Sydney Cochlear Implant Clinics has also demonstrated that young children can adapt to and benefit from improved speech processing strategies such as the Speak strategy. Reported speech perception results for implanted children show that a considerable proportion (60%) of paediatric patients in the Melbourne and Sydney clinics are able to understand some open set speech using electrical stimulation alone. These results, and the upward trend of speech perception benefits to improve over time with advances in speech processing. have raised questions as to whether severely, or severely-to-profoundly deaf children currently using hearing aids would in fact benefit more from a cochlear implant. To investigate the potential effect of the level of preoperative residual hearing on postoperative speech perception. results for all implanted children in the Melbourne and Sydney cochlear implant programs were analysed. Results showed that as 8 group, children with higher levels of preoperative residual hearing were consistently more likely to achieve open-set speech perception benefits. Potential factors in this finding could be higher levels of ganglion cell survival or greater patterning of the auditory pathways using conventional hearing aids prior to implantation. Conversely, children with the least preoperative residual hearing were less predictable, with some children achieving open-set perception, and others showing more limited closed-set benefits to perception. For these children, it is likely that preoperative residual hearing is of less significance than other factors in outcomes.