Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 37
  • Item
    Thumbnail Image
    Renewal-process approximation of a stochastic threshold model for electrical neural stimulation
    Bruce, Ian C. ; Irlicht, Laurence S. ; White, Mark W. ; O'Leary, Stephen J. ; Clark, Graeme M. ( 2000)
    In a recent set of modelling studies we have developed a stochastic threshold model of auditory nerveresponse to single biphasic electrical pulses (Bruce et al., 1999c) and moderate rate (less than 800 pulses per second) pulse trains (Bruce et al., 1999a). In this article we derive an analytical approximation for the single-pulse model, which is then extended to describe the pulse-train model in the case of evenly timed, uniform pulses. This renewal process description provides an accurate and computationally efficient model of electrical stimulation of single auditory nerve fibers by a cochlear implant that may be extended to other forms of electrical neural stimulation.
  • Item
    Thumbnail Image
    Frequency discrimination and the spiral ganglion cell population in cats [Abstract]
    Black, Raymond C. ; Steel, A. C. ; Clark, Graeme M. ( 1981)
    Our previous studies on electrical stimulation of the cochlea and auditory nerve have been performed to provide information about cochlear current distributions and electroanatomy, as well as indicating ways of exciting discrete auditory nerve fibre populations to aid in the design of a multiple channel cochlear implant (Black &Clark, 1980). The present study has been carried out to examine the relationship between the size of the spiral ganglion cell population which remains after experimentally-induced graded degeneration of the auditory nerve has occurred and the ability of an animal to perceive certain electrically induced sounds. This is of special interest for a cochlear hearing prosthesis which requires a residual auditory nerve population large enough to adequately relay the electrically induced activity to higher centres.
  • Item
    Thumbnail Image
    Inner ear implants
    Clark, Graeme M. (Dekker, 2004)
    The cochlear implant is an electronic device that brings useful hearing to severely to profoundly deaf people through multiple-channel electrical stimulation of the auditory nerves in the inner ear. This is required if their inner ears are so badly damaged by injury and disease, or so inadequately developed, that they cannot provide sufficient hearing for communication, even when the sound is amplified with a hearing aid. By stimulating the nerve directly with patterns of electrical pulses, the implant bypasses the normal function of the sense organ of hearing in the inner ear to partially reproduce the coding of sound. It consists of a wearable speech processor that picks up sound with a microphone, analyzes the signal, and then sends it by radio waves to the implanted receiver stimulator, which decodes the message and stimulates the electrode wires inserted into the inner ear.
  • Item
    Thumbnail Image
    Temporal processing from the auditory nerve to the medial nucleus of the trapezoid body in the rat
    Paolini, AG ; FitzGerald, JV ; Burkitt, AN ; Clark, GM (ELSEVIER SCIENCE BV, 2001-09)
    This investigation examines temporal processing through successive sites in the rat auditory pathway: auditory nerve (AN), anteroventral cochlear nucleus (AVCN) and the medial nucleus of the trapezoid body (MNTB). The degree of phase-locking, measured as vector strength, varied with intensity relative to the cell's threshold, and saturated at a value that depended upon stimulus frequency. A typical pattern showed decline in the saturated vector strength from approximately 0.8 at 400 Hz to about 0.3 at 2000 Hz, with similar profiles in units with a range of characteristic frequencies (480-32,000 Hz). A new expression for temporal dispersion indicates that this variation corresponds to a limiting degree of temporal imprecision, which is relatively consistent between different cells. From AN to AVCN, an increase in vector strength was seen for frequencies below 1000 Hz. At higher frequencies, a decrease in vector strength was observed. From AVCN to MNTB a tendency for temporal coding to be improved below 800 Hz and degraded further above 1500 Hz was seen. This change in temporal processing ability could be attributed to units classified as primary-like with notch (PL(N)). PL(N) MNTB units showed a similar vector strength distribution to PL(N) AVCN units. Our results suggest that AVCN PL(N) units, representing globular bushy cells, are specialised for enhancing the temporal code at low frequencies and relaying this information to principal cells of the MNTB.
  • Item
    Thumbnail Image
    Reduction in excitability of the auditory nerve following electrical simulation at high stimulus rates. II. Comparison of fixed amplitude with amplitude modulated stimuli
    TYKOCINSKI, MICHAEL ; Shepherd, Robert K. ; Clark, Graeme M. ( 1997)
    We have previously shown that acute electrical stimulation of the auditory nerve using charge-balanced biphasic current pulses presented continuously can lead to a prolonged decrement in auditory nerve excitability (Tykocinski et al., Hear. Res. 88 (1995), 124-142). This work also demonstrated a reduction in electrically evoked auditory brainstem response (EABR) amplitude decrement when using an otherwise equivalent pulse train with a 50% duty cycle. In the present study we have extended this work in order to compare the effects of electrical stimulation using both fixed amplitude electrical pulse trains and amplitude modulated (AM) pulse trains that more accurately model the dynamic stimulus paradigms used in cochlear implants. EABRs were recorded from guinea pigs following acute stimulation using AM trains of charge-balanced biphasic current pulses. The extent of stimulus-induced reductions in the EABR were compared with our previous results using either fixed amplitude continuous, or 50% duty cycle pulse trains operating at 0.34 µC/phase (2 mA, 170 µs/phase) at 400 or 1000 pulses/s (Tykocinski et al., Hear. Res. 88 (1995) 124-142). The AM pulse train, operating at the same rates, was based on a I-s sequence of the most extensively activated electrode of a Nucleus Mini-22 cochlear implant using the SPEAK speech processing strategy exposed to 4-talker babble, and delivered the same total charge as the fixed amplitude 50% duty cycle pulse train. Two hours of continuous stimulation induced a significant, rate-dependent reduction in auditory nerve excitability, and showed only a slight post-stimulus recovery for monitoring periods of up to 6 hours. Following 2 or 4 h of stimulation using an otherwise equivalent pulse train with a 50% duty cycle or the AM pulse train, significantly less reduction in the EABR was observed, and recovery to pre-stimulus levels was generally rapid and complete. These differences in the extent of the recovery between the continuous waveform and both the 50% duty cycle and AM waveforms were statistically significant for both 400 and 1000 pulses/s stimuli. Consistent with our previous results, the stimulus changes observed using AM pulse trains were rate dependent, with higher rate stimuli evoking more extensive stimulus-induced changes. The present findings show that while stimulus-induced reductions in neural excitability are dependent on the extent of stimulus-induced neuronal activity, the use of an AM stimulus paradigm further reduces post-stimulus neural fatigue.
  • Item
    Thumbnail Image
    Estimating mechanical responses to pulsatile electrical stimulation of the cochlea
    McAnally, Ken I. ; Brown, Mel ; Clark, Graeme M. ( 1997)
    This study estimated the mechanical response of the cochlea to pulsatile electrical stimulation of the scala tympani of the cat. The auditory nerve compound action potential evoked by an acoustic probe was forward-masked by a train of charge-balanced biphasic current pulses. Masking as a function of probe frequency reflected the excitation pattern of the response to the masker and resembled the spectrum of the electrical stimulus. Both pulse rate and pulse width influenced the degree of masking. The vibration of a region of the basilar membrane was estimated by recording the local cochlear microphonic evoked by biphasic pulses. The amplitude of the cochlear microphonic was proportional to the amplitude of the spectral component of the electrical stimulus to which the local cochlear microphonic was tuned. These results are consistent with the generation of a mechanical response to the electrical stimulus.
  • Item
    Thumbnail Image
    The effects of stochastic neural activity in a model predicting intensity perception with cochlear implants: low-rate stimulation
    Bruce, Ian C. ; White, Mark W. ; Irlicht, Laurence S. ; O'Leary, Stephen J. ; Clark, Graeme M. ( 1999)
    Most models of auditory nerve response to electrical stimulation are deterministic, despite significant physiological evidence for stochastic activity. Furthermore, psychophysical models and analyses of physiological data using deterministic descriptions do not accurately predict many psychophysical phenomena. In this paper we investigate whether inclusion of stochastic activity in neural models improves such predictions. To avoid the complication of interpulse interactions and to enable the use of a simpler and faster auditory nerve model we restrict our investigation to single pulses and low-rate (<200 pulses/s) pulse trains. We apply signal detection theory to produce direct predictions of behavioural threshold, dynamic range and intensity difference limen. Specifically, we investigate threshold versus pulse duration (the strength-duration characteristics), threshold and uncomfortable loudness (and the corresponding dynamic range) versus phase duration, the effects of electrode configuration on dynamic range and on strength-duration, threshold versus number of pulses (the temporal-integration characteristics), intensity difference limen as a function of loudness, and the effects of neural survival on these measures. For all psychophysical measures investigated, the inclusion of stochastic activity in the auditory nerve model was found to produce more accurate predictions.
  • Item
    Thumbnail Image
    A stochastic model of the electrically stimulated auditory nerve: pulse-train response
    Bruce, Ian C. ; Irlicht, Laurence S. ; White, Mark W. ; O'Leary, Stephen J. ; Dynes, Scott ; Javel, Eric ; Clark, Graeme M. ( 1999)
    The single-pulse model of the companion paper [1] is extended to describe responses to pulse trains by introducing a phenomenological refractory mechanism. Comparisons with physiological data from cat auditory nerve fibers are made for pulse rates between 100 and 800 pulses/s. First, it is shown that both the shape and slope of mean discharge rate curves are better predicted by the stochastic model than by the deterministic model. Second, while interpulse effects such as refractory effects do indeed increase the dynamic range at higher pulse rates, both the physiological data and the model indicate that much of the dynamic range for pulse-train stimuli is due to stochastic activity. Third, it is shown that the stochastic model is able to predict the general magnitude and behavior of variance in discharge rate as a function of pulse rate, while the deterministic model predicts no variance at all.
  • Item
    Thumbnail Image
    Research advances for cochlear implants
    Clark, Graeme M. ( 1998)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Intracellular responses of the rat anteroventral cochlear nucleus to intracochlear electrical stimulation
    Paolini, Antonio G. ; Clark, Graeme M. ( 1998)
    Unavailable due to copyright.