Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.
  • Item
    Thumbnail Image
    Latest results for adults & children using cochlear implants & future implications
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    The overall success of a cochlear implant procedure is most often quantified by assessing how well implantees can understand speech. This is because a primary aim of the application of cochlear implants is to improve communication, and it is relatively straightforward to obtain accurate measures of speech recognition. The quality of cochlear implant hearing is not well described by measuring an audiogram, as the detection of sound is similar across all implantees if the device is functioning correctly. A commonly used measure of speech understanding is the CID everyday sentence test where the number of correctly identified words within sentences is assessed. In the early days of cochlear implants, subjects could only recognize a few words without lipreading but the most recent results show average scores of 80% without lipreading for this sentence test, after 6 months of experience with the device.
  • Item
    Thumbnail Image
    Results for the Nucleus multiple-electrode cochlear implant in two children [Abstract]
    Tong, Y. C. ; Blamey, P. J. ; Dowell, R. C. ; Nienhuys, T. G. ; Musgrave, G. N. ; Busby, P. A. ; Roberts, S. A. ; Rickards, F. W. ; Dettman, S. J. ; Altidis, P. M. ; Clark, Graeme M. ( 1988)
    Two males, 9 years 10 months (CHILD 1) and 5 years 5 months (CHILD 2) at time of surgery, were implanted with the Nucleus multiple-electrode cochlear implant. Both patients were deafened as a result of meningitis in their third year. Assessments of speech perception, speech production and language skills were undertaken at regular intervals, pre and post operatively. For both patients in the audition alone condition, some speech perception post operative scores were significantly higher than pre operative scores and progressive improvements in scores over successive post operative data collection times were seen. Significant differences between the visual alone and auditory-visual condition scores were also observed for CHILD 1 post operatively. Speech production post operative scores were significantly higher than pre operative scores for both patients. The receptive vocabulary scores for both patients improved at a higher rate than that of age-matched normal children. The acquisition of expressive and receptive language skills for CHILD 2 was at a higher rate than that of age-matched children. Differences in the results between the two patients were seen, and this may be related to age and duration of deafness.