Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 5 of 5
  • Item
    Thumbnail Image
    Speech perception in children using cochlear implants: prediction of long-term outcomes.
    Dowell, RC ; Dettman, SJ ; Blamey, PJ ; Barker, EJ ; Clark, GM (Informa UK Limited, 2002-03)
    A group of 102 children using the Nucleus multichannel cochlear implant were assessed for open-set speech perception abilities at six-monthly intervals following implant surgery. The group included a wide range of ages, types of hearing loss, ages at onset of hearing loss, experience with implant use and communication modes. Multivariate analysis indicated that a shorter duration of profound hearing loss, later onset of profound hearing loss, exclusively oral/aural communication and greater experience with the implant were associated with better open-set speech perception. Developmental delay was associated with poorer speech perception and the SPEAK signal coding scheme was shown to provide better speech perception performance than previous signal processors. Results indicated that postoperative speech perception outcomes could be predicted with an accuracy that is clinically useful.
  • Item
    Thumbnail Image
    Variation in speech perception scores among children with cochlear implants
    Sarant, JZ ; Blamey, PJ ; Dowell, RC ; Clark, GM ; Gibson, WPR (LIPPINCOTT WILLIAMS & WILKINS, 2001-02)
    OBJECTIVE: The objective of this study was to identify common factors affecting speech perception scores in children with cochlear implants. DESIGN: Speech perception data for 167 implanted children were collected at two cochlear implant centres in Melbourne and Sydney. The data comprised audition-alone scores on open-set word and sentence tests. Children were selected on the basis that they had a Nucleus 22-electrode cochlear implant. The average age of the children was 5 yr. Information was also collected about 12 factors that may have influenced speech perception scores for each child. Analysis of covariance was used to identify factors that significantly affected speech perception scores. Pearson pairwise correlation coefficients were also calculated for all factors analyzed. RESULTS: The analyses in this study identified factors that accounted for 51%, 34%, and 45% of the variance in phoneme, word and sentence perception scores. Scores decreased by 1.4 to 2.4% per year of profound deafness prior to implantation. Children who normally use oral communication scored significantly higher than children normally using sign or simultaneous oral and sign communication. Children implanted in Sydney scored higher on average than children implanted in Melbourne. CONCLUSIONS: The results show that a significant part of the variation in speech perception scores is systematically related to audiological and environmental factors for each child. The reasons for significant differences between children using different communication modes or from different clinics were not identified.
  • Item
    Thumbnail Image
    The development of speech perception in children using cochlear implants: effects of etiologic factors and delayed milestones
    PYMAN, BRIAN ; Blamey, Peter J. ; Lacy, Peter ; Clark, Graeme M. ; DOWELL, RICHARD ( 2000)
    Hypothesis: Speech perception outcomes for cochlear implantation of children vary over a wide range, and it is hypothesized that central pathologic states associated with certain causes of hearing impairment account for a substantial part of the variance. Study Design: A retrospective analysis was carried out to ascertain the relationships between speech perception, etiologic factors, and central pathologic states as indicated by preoperative delayed motor milestones and/or cognitive delays. Setting: Data were obtained from the pre-and postoperative records of patients attending a hospital cochlear implant clinic. Patients: Results for 75 consecutive patients up to age 5 years who underwent implantation were included in the study. Intervention: Patients received a 22-electrode cochlear prosthesis and were seen by the clinic for regular tune-up and assessments. Home-and school-based habilitation was recommended by the clinic. Main Outcome Measures: Speech perception measures were classified on a five-point scale to allow for different evaluation procedures at different ages and developmental stages. Results: The incidence of motor and cognitive delays were fairly evenly spread across etiologic factors, except for cytomegalovirus, which had a much higher than average incidence. Children with motor and/or cognitive delays were significantly slower than other children in the development of speech perception skills after implantation. Etiologic factors did not have a statistically significant effect on speech perception outcome. Conclusions: It is likely that central pathologic states account for a substantial part of the variance among children using cochlear implants. Specific indicators of central pathologic states should be used to assess a child's prognosis in preference to less specific information based on etiologic factors alone.
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.
  • Item
    Thumbnail Image
    Latest results for adults & children using cochlear implants & future implications
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    The overall success of a cochlear implant procedure is most often quantified by assessing how well implantees can understand speech. This is because a primary aim of the application of cochlear implants is to improve communication, and it is relatively straightforward to obtain accurate measures of speech recognition. The quality of cochlear implant hearing is not well described by measuring an audiogram, as the detection of sound is similar across all implantees if the device is functioning correctly. A commonly used measure of speech understanding is the CID everyday sentence test where the number of correctly identified words within sentences is assessed. In the early days of cochlear implants, subjects could only recognize a few words without lipreading but the most recent results show average scores of 80% without lipreading for this sentence test, after 6 months of experience with the device.