Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 10
  • Item
    Thumbnail Image
    Psychophysical matching of sensations produced by acoustic and electrical stimulation of the auditory nerve [Abstract]
    Blamey, P. J. ; Dowell, R. C. ; Tong, Y.C. ; Clark, Graeme M. (Monash University Press, 1983)
    The aim of this study was to establish an acoustic model of a multiple-channel cochlear implant that could be used in the development of speech coding strategies. Identical psychophysical tests were carried out with electrical stimuli for two cochlear implant patients and with acoustic stimuli for three normally hearing listeners. Each electrical stimulus was a train of biphasic pulses at a constant rate between 50 and 100 pps directed to one of the 10 electrodes spaced at 1.5mm intervals around the basal turn of the cochlea (Clark et al. 1977). The corresponding acoustic stimulus was a train of noise bursts at a rate equal to the electrical pulse rate. The noise bursts were passed through one of 8 bandpass filters with centre frequencies equally spaced on a logarithmic scale from 1140 to 10880 Hz representing 8 different electrodes.
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.
  • Item
    Thumbnail Image
    Latest results for adults & children using cochlear implants & future implications
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    The overall success of a cochlear implant procedure is most often quantified by assessing how well implantees can understand speech. This is because a primary aim of the application of cochlear implants is to improve communication, and it is relatively straightforward to obtain accurate measures of speech recognition. The quality of cochlear implant hearing is not well described by measuring an audiogram, as the detection of sound is similar across all implantees if the device is functioning correctly. A commonly used measure of speech understanding is the CID everyday sentence test where the number of correctly identified words within sentences is assessed. In the early days of cochlear implants, subjects could only recognize a few words without lipreading but the most recent results show average scores of 80% without lipreading for this sentence test, after 6 months of experience with the device.
  • Item
    Thumbnail Image
    Pre- & post-operative factors affecting speech perception in adult cochlear implant users
    Blamey, Peter J. ; Clark, Graeme M. ; Dowell, Richard C. ( 1997)
    A common feature of published studies of cochlear implantation is a very wide range of performance levels within a group of patients. It is well-established that preoperative factors including duration of deafness, age at implantation, duration of implant use and etiology can have statistically significant effects on speech perception with a cochlear implant, but they do not account for a very high proportion of the variance within groups of implant users. The biological basis for these effects is not well established. For example, it is unclear whether the effect of duration of deafness is due to a decrease in the number of surviving ganglion cells in the cochlea, to the detailed distribution of functional neurons within the cochlea, to degeneration of nerve function at higher auditory centers, to plastic neural effects during deafness, or to a combination of all of these mechanisms. Data for other factors may cast some light on these possibilities.
  • Item
    Thumbnail Image
    The auditory cortex and auditory deprivation: experience with cochlear implants in the congenitally deaf [Abstract]
    Shepherd, R. K. ; Hartmann, R. ; Heid, S. ; Klinke, R. ; Blamey, P. J. ; Dowell, R. C. ; Clarke, Graeme M. ( 1995)
    The primary auditory cortex (AI) exhibits a topographic representation of the organ of Corti in normal hearing animals. Plasticity studies have shown that this orderly representation of frequency can be modified following a restricted hearing loss or by behavioural trainingl,2. Little is known, however, of the effects of a profound hearing loss on AI, although a number of early studies have suggested an enhancement of activity from other modalities3. Knowledge of the functional status of the central auditory pathway in the profoundly deaf, and the ability of these structures to undergo reorganization particularly following long periods of auditory deprivation - are important issues for the clinical management of cochlear implant patients. In this paper we review our recent clinical and experimental experience with cochlear implants in the congenitally deaf.
  • Item
    Thumbnail Image
    Clinical comparison of open-set speech perception with MSP and WSPIII speech processors and preliminary results for the new SPEAK processor [Abstracts]
    Whitford, Lesley A. ; Partick, James F. ; Clark, Graeme M. ; Dowell, Richard C. ; Marsh, Michael A. ; HOLLOW, RODNEY ; Blamey, Peter J. ; Pyman, Brian C. ; Seligman, Peter M. ( 1993)
    There are several studies which compare the WSP III (FOIF11F2) and MSP (Multipeak) speech processors for the Nucleus multiple-channel cochlear implant in small, controlled groups of patients. In the present study we were interested in the benefits of open set speech perception provided by the MSP over the prior WSP III speech processor in a large, unselected clinical population.
  • Item
    Thumbnail Image
    Future directions in the clinical application of multichannel cochlear prostheses [Abstract]
    Dowell, Richard C. ; Blamey, Peter J. ; McDermott, H. J. ; Clark, Graeme M. ( 1992)
    Three main areas of work at the University of Melbourne relating to the clinical application of multichannel cochlear prostheses will be discussed. Speech perception results for 40 children and adolescents implanted with the Nucleus multichannel device will be presented with an analysis of potentially predictive clinical factors. Overall results have shown that 60% of the children have developed useful open-set speech recognition ability without visual cues. Due to the improved speech perception for postlinguistically deafened adult cochlear implant patients, the multichannel implant has become a viable alternative for patients with some useful residual hearing. A "bimodal" speech processor which provides acoustic output for the residual hearing ear and electrical output for the cochlear implant will also be discussed. This device provides a flexible, programmable acoustic processor which can make use of feature coding aspects of the implant processing. The "bimodal" device has also addressed problems of incompatibility of the implant signal with the acoustic signal from conventional hearing aids. Results for the new "Spectral Maxima Speech Processor" (SMSP) will also be presented. The SMSP has shown improved speech perception performance in quiet and in noise when compared with the MSP (MULTIPEAK) system, currently in use with the Nucleus device. Results for four subjects with the SMSP showed mean scores of 57.4% for open-set monosyllabic words in quiet, and 78.7% for open-set sentences in a 10 dB signal-to-noise ratio
  • Item
    Thumbnail Image
    Future developments in speech processing for multichannel cochlear implants in children [Abstract]
    Dowell, Richard C. ; Dooley, G. ; McDermott, H. D. ; Blamey, P. ; McKay, C. ; Clark, Graeme M. ( 1992)
    The average speech perception score for adult implant patients is now about 60% on an open-set sentence test without lipreading. This is higher than the scores obtained by many profound and severe-to-profoundly impaired hearing aid users. This suggests that some hearing aid users, particularly those who use a hearing aid in one ear only, could benefit from a cochlear implant. As neither the implant nor the hearing aid will provide perfect speech recognition it is to be expected that this group should obtain maximum benefit by using the hearing aid in one ear together with the implant in the other ear. However, experience with this group of patients has shown that many people find the use of two independent devices unacceptable. Furthermore, perceptual interaction of the acoustic and electrical signals makes it desirable to be able to control the two outputs in a more co-ordinated way than is possible with two independent devices. Consequently, a "bimodal" speech processor has been developed with both acoustic and electrical outputs controlled from the same speech processing unit. Feature coding aspects of the implant processing have been applied to the acoustic signal in such a way as to enhance speech perception with the hearing aid and improve compatibility with the implant. Initial testing with the bimodal aid shows promise to help severely-to-profoundly impaired individuals. The device has also been useful as a research tool to investigate the complex interactions of simultaneous acoustic and electrical stimulation. The Spectral Maxima Sound Processor (SMSP) has also been developed at the University of Melbourne for use with the Nucleus cochlear implant. Studies with adult subjects have shown improved perception of vowels, consonants, words and sentences in quiet and sentences in background noise with the SMSP as compared with the MSP(MULTIPEAK) which is currently supplied for use with this implant. Results for four subjects showed mean scores for open set sentences at a 10 dB signal-to-noise ratio of 78.7% for the SMSP and 50.0% for the MSP. Mean scores for the same group on open set monosyllabic words in quiet were 57.4% for SMSP and 39.9% for MSP. These results suggest that future improvements in speech perception will be possible for children using the Nucleus cochlear implant.
  • Item
    Thumbnail Image
    Factors affecting speech perceptual performance for children using the 22-electrode cochlear prosthesis [Abstract]
    Dowell, Richard C. ; Blamey, Peter J. ; Clark, Graeme M. ( 1992)
    Speech perception results for all 40 children and adolescents implanted with the. Nucleus 22 electrode cochlear prosthesis in Melbourne (as of February 1, 1992) were used to categorize performance for each child into one of six hierarchical groups: 1: detection of speech including high frequencies 2: discrimination of suprasegmental features of speech in addition to 1,3: discrimination and recognition of .vowel sounds in addition to 1 and 2,.4: discrimination arid recognition of consonant sounds in addition to 1, 2 and 3,5: open set speech. recognition with scores less than 20% for unfamiliar material in addition to 1 to 4,6: open set speech recognition with scores greater than 20% for unfamiliar material in addition to 1 to 5, above.All children demonstrated discrimination of suprasegmentals (level 2) and 58% demonstrated some openset speech recognition (levels 5 and 6). The pattern of results suggested that children who can discriminate segmental features of speech tend to achieve open set speech perception after adequate experience with the prosthesis. The performance level, described above, was used as the dependent variable in a multiple regression analysis to assess the effect of various factors on speech perception performance. The duration of profound hearing impairment and the amount of experience with the prosthesis were shown to contribute significantly to the variance, in performance level. A weaker trend was evident (or recently implanted children which may suggest that those' in oral/aural educational settings progress more rapidly, in terms of speech perception, than those in total communication settings. Age at implantation, cause of deafness, hearing levels prior to implantation, and number of electrodes in use, did not contribute significantly. to the variance in speech perception performance for these children. The results showed that all children with less than seven years of profound hearing impairment and with over one year of experience with the prosthesis have achieved some open-set speech recognition. This is an encouraging result as the trend in clinical application of cochlear prostheses has been towards implanting younger children in recent years. If this sample of hearing-impaired children in Melbourne is representative of the general population, we may expect that most implanted young children will ,develop reasonable speech perception skills after adequate experience and training.
  • Item
    Thumbnail Image
    Results for the Nucleus multiple-electrode cochlear implant in two children [Abstract]
    Tong, Y. C. ; Blamey, P. J. ; Dowell, R. C. ; Nienhuys, T. G. ; Musgrave, G. N. ; Busby, P. A. ; Roberts, S. A. ; Rickards, F. W. ; Dettman, S. J. ; Altidis, P. M. ; Clark, Graeme M. ( 1988)
    Two males, 9 years 10 months (CHILD 1) and 5 years 5 months (CHILD 2) at time of surgery, were implanted with the Nucleus multiple-electrode cochlear implant. Both patients were deafened as a result of meningitis in their third year. Assessments of speech perception, speech production and language skills were undertaken at regular intervals, pre and post operatively. For both patients in the audition alone condition, some speech perception post operative scores were significantly higher than pre operative scores and progressive improvements in scores over successive post operative data collection times were seen. Significant differences between the visual alone and auditory-visual condition scores were also observed for CHILD 1 post operatively. Speech production post operative scores were significantly higher than pre operative scores for both patients. The receptive vocabulary scores for both patients improved at a higher rate than that of age-matched normal children. The acquisition of expressive and receptive language skills for CHILD 2 was at a higher rate than that of age-matched children. Differences in the results between the two patients were seen, and this may be related to age and duration of deafness.