Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 4 of 4
  • Item
    Thumbnail Image
    A comparison of a new prototype Tickle Talker with a Tactaid 7
    Galvin, Karyn L. ; Ginis, Jan ; Cowan, Robert S. C. ; Blamey, Peter J. ; Clark, Graeme M. ( 2001)
    This study compared the speech perception enhancement provided by two multichannel tactile aids: a new version of the Tickle TalkerT™ and the Tactaid 7. The subjects' impression of benefit was also examined. In an AB pattern, six adults with hearing impairment used each device daily for approximately 18 weeks and attended 12 training sessions. When tactile information was provided, the group demonstrated a significant enhancement for the perception of words (mean 17.2%) and phonemes (mean 12.9%) in monosyllabic word lists, words in sentences (mean 14.2%) and speech tracking (mean 7.7 wpm). The Tactaid 7 provided a significantly greater enhancement for the perception of words (21 % versus 13.4%), phonemes (16.7% versus 9.1%) and some speech features in monosyllabic word lists. Subjective ratings were slightly higher for the Tactaid 7, and four subjects preferred this device. Either device may be suitable for those not able or willing to have a cochlear implant.
  • Item
    Thumbnail Image
    The development of speech perception in children using cochlear implants: effects of etiologic factors and delayed milestones
    PYMAN, BRIAN ; Blamey, Peter J. ; Lacy, Peter ; Clark, Graeme M. ; DOWELL, RICHARD ( 2000)
    Hypothesis: Speech perception outcomes for cochlear implantation of children vary over a wide range, and it is hypothesized that central pathologic states associated with certain causes of hearing impairment account for a substantial part of the variance. Study Design: A retrospective analysis was carried out to ascertain the relationships between speech perception, etiologic factors, and central pathologic states as indicated by preoperative delayed motor milestones and/or cognitive delays. Setting: Data were obtained from the pre-and postoperative records of patients attending a hospital cochlear implant clinic. Patients: Results for 75 consecutive patients up to age 5 years who underwent implantation were included in the study. Intervention: Patients received a 22-electrode cochlear prosthesis and were seen by the clinic for regular tune-up and assessments. Home-and school-based habilitation was recommended by the clinic. Main Outcome Measures: Speech perception measures were classified on a five-point scale to allow for different evaluation procedures at different ages and developmental stages. Results: The incidence of motor and cognitive delays were fairly evenly spread across etiologic factors, except for cytomegalovirus, which had a much higher than average incidence. Children with motor and/or cognitive delays were significantly slower than other children in the development of speech perception skills after implantation. Etiologic factors did not have a statistically significant effect on speech perception outcome. Conclusions: It is likely that central pathologic states account for a substantial part of the variance among children using cochlear implants. Specific indicators of central pathologic states should be used to assess a child's prognosis in preference to less specific information based on etiologic factors alone.
  • Item
    Thumbnail Image
    Improved sound processing for cochlear implants
    James, C.J. ; Just, Y. ; Knight, M.R. ; Martin, L.F.A. ; McKay, C.M. ; Plant, K.L. ; Tari, S. ; Vandali, A.E. ; Clark, Graeme M. ; Cowan, R.S.C. ; McDermott, H. J. ; Blamey, P. J. ; Dawson, P. ; Fearn, R. A. ; Grayden, D. B. ; Henshall, K. R. ( 2002)
    Four signal processing schemes currently under development aim to improve the perception of sounds/ especially speech, for children and adults using the Nucleus cochlear implant system. The schemes are (1) fast-acting input-signal compression, (2) Adaptive Dynamic Range Optimisation (ADRO), (3) TESM, a scheme that emphasises transients in signals, and (4) DRSP, a strategy that applies different stimulation rates to selected sets of electrodes.
  • Item
    Thumbnail Image
    What factors contribute to successful outcomes for children using cochlear implants
    Cowan, Robert C. ; Clark, Graeme M. ; Dowell, Richard C. ; Dettman, Shani J ; Barker, Elizabeth ; Latus, Katie ; Hollow, Rod ; Blamey, Peter J. ( 2000)
    Long term speech perception data has been collected for 100 children using the Nucleus multichannel cochlear prosthesis in Melbourne. Scores on a number of different assessments are available at approximately six month intervals following implantation for these children. The group represents an unselected sample of cochlear implant users, as all children were included if they had sufficient developmental skills to perform formal speech perception tests. Information was also collected on each child regarding type of hearing loss, age of onset of profound hearing loss, duration of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech processing strategy and length of experience with implant use.