    Rehabilitation strategies for adult cochlear implant users
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    This paper summarizes open-set speech perception results using audition alone for a large group of adult Nucleus cochlear implant users in Melbourne. The results show wide variation in performance but significant improvement over the years from 1982 to 1995. Analysis of these results shows that speech processor developments have made the major contribution to this improvement over this time. Recent results for patients using the SPECTRA-SPEAK processor show !hat most subjects obtain good speech perception within six months of implantation and the need for intensive auditory training is minimal for many of these patients. Postoperative care should encourage consistent device use by providing opportunities for success and providing long term technical support for implant users. In some cases, including elderly patients, those with long term profound deafness, and those with special needs, there will still be a need for additional rehabilitation and auditory training support.
  • Item
    Thumbnail Image
    Factors affecting outcomes in children with cochlear implants
    Dowell, R. C. ; Blamey, P. J. ; Clark, Graeme M. (Monduzzi Editore, 1997)
    Open-set speech perception tests were completed for a group of 52 children and adolescents who were long-term users of the Nucleus multiple channel cochlear prosthesis. Results showed mean scores for the group of 32.4% for open-set BKE sentences and 48.1% for phonemes in open-set monosyllabic words. Over 80% of the group performed significantly on these tas1cs. Age at implantation was identified as a significant factor affecting speech perception performance with improved scores for children implanted early. This factor was evident in the results at least down to the age of three years. Duration.. of profound hearing loss, progressive hearing loss, educational program and preoperative residual hearing were also identified as significant factors that may affect speech perception performance.
  • Item
    Thumbnail Image
    Fricative perception by cochlear implant users
    Blamey, P. J. ; Tartter, V. C. ( 1992)
    Three implant users were tested with 45 syllables consisting of[v, f, �, ?, z, s, ?, ?, d?, t ?, ?, , d, n, 1] before the vowels [I ,a,u] with three wearable speech processors. The WSP3 processor coded first and second formant frequencies and amplitudes. The MSP1 processor used a similar scheme with improved measurement and coding of the formants. The MSP2 processor added amplitude information from three higher frequency bands. Average scores were 42% for WSP3, 54% for MSP1, and 57% for MSP2. Perception of voicing, manner, and place of articulation of the consonants was significantly greater for the MSP processors than the WSP3 processor. Place perception was slightly higher for MSP2 than MSP1. The listeners used three perceptual dimensions which were highly correlated with the frequencies and amplitudes of peaks in the low frequency region of the frication spectrum, amplitudes of high frequency peaks, and duration of the frication noise.
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Busby, P. A. ; Brown, A. M. ; DOWELL, RICHARD ; Rickards, Field W. ; Dawson, Pam W. ; Blamey, Peter J. ; Rowland, L.C. ; Dettman, Shani J. ; Altidis, P. M. ; Clark, Graeme M. ( 1989)
    Paper presented at the 118th Meeting of the Acoustical Society of America