    Introduction: International Cochlear Implant, Speech and Hearing Symposium - Melbourne 1994
    Clark, Graeme M. ; Cowan, Robert S. C. ( 1995)
    The International Cochlear Implant Speech and Hearing Symposium - Melbourne 1994 covered a wide range of presentations in a number of disciplines. The scientific program included 287 oral presentations and 40 posters, presented to a total of 456 delegates from 38 countries. This was a considerable expansion in the number and range of presentations from the first international conference held in Melbourne in 1985 (Ann Otol Rhinal Laryngal 1987;96[suppl 128]). This growth highlights the importance of the discipline and the advances being made in this area.
  • Item
    Thumbnail Image
    Results for children and adolescents using the multichannel cochlear prosthesis [Abstract]
    Dowell, Richard C. ; Clark, Graeme M. ; Dettman, Shani J. ; Dawson, Pamela W. ( 1992)
    The first adolescent to use the 22-electrode cochlear prosthesis was Implanted In Melbourne in 1985 and the first child (less than 10 years), the following year. Since then, over 100 children have received the cochlear prosthesis in Australia and over 1200 worldwide. Detailed assessment of 200 children in the U.S.A., Australia and Germany lead to the market approval of the prosthesis by the U.S. Food and Drug Administration in July 1990. The analysis of results for these children has proven to be difficult due to the use of different tests in different places, the lack of appropriate assessment tools for young children, the wide range of performance, and the problems of cooperation for young children. Despite these problems, some trends are beginning to emerge in the speech perception results for implanted children. Children with a greater amount of auditory experience before becoming profoundly deaf tend to perform better, as do children with more experience with the cochlear prosthesis. Those with a greater number of electrodes in use also perform better, a result supported by adult studies. Although older prelinguistically deafened children do not perform as well as postlinguistically deafened adults, there appears to be little difference between results for pre-and post-linguistically deafened young children. These trends In speech perception results will be discussed in more detail.
  • Item
    Thumbnail Image
    Place pitch perception with multiple electrode cochlear implants: the use of concurrent activation of nearby electrodes to produce additional ptich percepts [Abstract]
    McDermott, Hugh J. ; McKay, Colette M. ( 1992)
    In multiple electrode cochlear implants, each electrode produces a pitch percept which is usually related monotonically to its distance from the round window. The number of these pitch percepts is limited by the number of usable electrodes and their discriminability, varying up to a maximum of 22 for the mini-system 22 implant but sometimes significantly less. A study on two implanted subjects in which the pitch of pulse trains on two concurrently activated nearby electrodes was compared with the pitch produced when each of the electrodes was activated on its own, showed that the pitch of the concurrently activated electrodes was different from each component electrode and was placed in an intermediate position. Furthermore the pitch of the concurrent stimulation could be altered by adjusting the relative current levels on the two component electrodes. This may partly explain the improvements, particularly in vowel discrimination, obtained with the SMSP strategy described in the accompanying paper.
  • Item
    Thumbnail Image
    Current advances in speech processing for the mini-system 22 implant [Abstract]
    McKay, Colette M. ; McDermott, H. J. ( 1992)
    The Spectral Maxima Sound Processor (SMSP) has been developed at the University of Melbourne for use with the mini-system 22 cochlear implant manufactured by Cochlear Pty Ltd. Studies with adult subjects have shown that perception of vowels, consonants, words. and sentences in quiet and in background noise is enhanced with the SMSP when compared with the MSP(MULJIPEAK) currently supplied for use with this implant. Studies comparing the ability of subjects to identify speakers and to identify intonation patterns have shown no reduction due to the SMSP's use of a constant rate of electrical stimulation. Qualitative remarks of subjects are consistent with improved perception in background noise and of degraded speech such as with TV and telephone use. They also report that environmental noises and music sound more natural. Further development of the SMSP strategy and formulation of new strategies are being facilitated by a new programmable processor utilising digital signal processing.