Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 44
  • Item
    Thumbnail Image
    Training place pitch perception in cochlear implant users [Abstract]
    Dawson, Pam ; Clark, Graeme M. ( 1997)
    The study has aimed at determining whether the ability to use place coded vowel formant information could be enhanced with analytical vowel training in a group of -congenitally deafened patients, who showed limited speech perception skills after cochlear implant experience ranging from 1y8m to 6y11m. It has investigated whether improvements in vowel perception after training can carry over to word recognition. A further objective was to see whether poorer vowel perception was associated with poorer electrode position difference limens. Three children, one adolescent and one young adult were assessed with synthesized versions of the words /hid, head, had, hud, hod, hood/ and a natural version of these words as well as with a closed-set monosyllabic word task. The change in performance after 10 training sessions was compared to the change in performance during a non-training period. Four of the five patients showed a significant gain in synthetic vowel perception post-training on at least one assessment, but only two patients showed gains across a number of tests post-training. For one of these 2 children improvements in vowel perception generalized to word perception. Patients’ electrode limens ranged from 1 to 3 electrodes except for 1 adolescent whose minimal progress post-training could be partly explained by poorer apical electrode discrimination. The findings are discussed with reference to a number of factors, including the notion of a "critical period" for neural plasticity.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: I. Effect on residual hearing [Abstract]
    Xu, J. ; Shepherd, R. K. ; Clark, Graeme M. ( 1996)
    In addition to direct excitation of auditory nerve fibres, cochlear implant patients with small amounts of residual hearing may receive important additional auditory cues via electrophonic activation of hair cells 1. Before incorporating electrophonic hearing into speech processing strategies, the extent of hair cell survival following cochlear implantation must first be determined. We have recently demonstrated widespread survival of hair cells apical to electrode arrays implanted for periods of up to three years, the present report describes the effects of chronic electrical stimulation on hair cell survival.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: II. Cochlear pathophysiology [Abstract]
    Shepherd, R. K. ; Xu, J. ; Clark, Graeme M. ( 1996)
    A major factor in the improved performance of cochlear implant patients has been the use of high stimulus rate speech processing strategies. While these strategies show clear clinical advantage, we know little of their long-term safety. Indeed, recent studies have indicated that high stimulus rates at intensities above clinical limits, can result in neural damage as a result of prolonged neuronal hyperactivity. The present study was designed to evaluate the effects of chronic electrical stimulation of the auditory nerve at high rates, using intensities within clinical limits.
  • Item
    Thumbnail Image
    Spatial representation of the cochlea within the inferior colliculus of neonatally deafened kittens following chronic electrical stimulation of the auditory nerve [Abstract]
    Shepherd, R. K. ; Martin, R. L. ; Brown, M. ; Clark, Graeme M. ( 1995)
    The orderly tonotopic representation of the cochlea is accurately reproduced within the central auditory system of normal hearing animals. Any degradation of this representation as a result of a neonatal hearing loss or chronic electrical stimulation during development could have important implications for the use of multichannel cochlear implants in young children. In the present study we have used 2-deoxyglucose autoradiography (2-00) to examine the topographic representation of the cochlea within the inferior colliculus (IC) of neonatally deafened kittens following periods of chronic intracochlear electrical stimulation.
  • Item
    Thumbnail Image
    The pitch of amplitude-modulated electrical stimuli in cochlear implantees [Abstract]
    McKay, Colette M. ; McDermott, Hugh J. ; Clark, Graeme M. ( 1993)
    The ability of cochlear implantees to detect amplitude modulation of pulsatile electrical stimulation, suggests that some speech feature information may be conveyed effectively by this means. For example, modulations at the fundamental frequency of speech may provide a voice pitch percept to implantees, particularly in speech processing strategies which generate constant-rate stimulation. The pitch evoked by sinusoidally modulated current pulse trains on a single electrodes has been studied. Modulation frequencies of 100, 150 and 200Hz, and carrier pulse rates varying from 200 to 1200Hz, were used. The results showed that the pitch of the stimulation was related to the modulation frequency, provided that either the carrier rate was a multiple of the modulation frequency, or the carrier rate was sufficiently high (at least four times the modulation frequency for the stimuli studied here). Furthermore, when the modulated stimuli were matched in pitch to non-modulated pulse trains, it was. found that the rate of the matched non-modulated stimuli was close to but somewhat higher than the modulation frequency. This difference depended on the carrier rate and varied among subjects.
  • Item
    Thumbnail Image
    Insertion study using new peri-modiolar electrode array designs [Abstract]
    Treaba, Claudiu ; Clark, Graeme M. ; Cowan, Robert S. ; Tykocinski, Michael J. ; Cohen, Lawrence T. ; Saunders, Elaine ; Pyman, Brian C. ; Briggs, Robert S. ; Dahm, Markus C. ( 1999)
    Intracochlear multi-channel cochlear implants have been shown to successfully provide auditory information for profoundly deaf patients by electrically stimulating discrete populations of auditory nerve fibers via a scala tympani (ST) electrode array. Histological and radiological examination of implanted human temporal bones showed that the current straight Nucleus® array is usually positioned against the outer wall of the ST. An electrode array close to the modiolus could be expected to reduce stimulation thresholds and result in a more localized neural excitation pattern.
  • Item
    Thumbnail Image
    Psychophysics of a peri-modiolar electrode array
    Cohen, Lawrence T. ; Saunders, E. ; Clark, Graeme M. ( 1999)
    Psychophysical findings in three adult patients implanted with a CI22 cochlear prosthesis (Cochlear Limited) fitted with a developmental peri-modiolar electrode array have been reported. This array was moulded with a curvature approximating that of the inner wall of scala tympani but, after straightening and insertion into the cochlea, it adopted a position on average approximately half way between the inner and outer walls. However, the considerable variations in electrode trajectories across subjects allowed an analysis which could separate the effects due to longitudinal distance into the cochlea and lateral distance from the modiolus. Radiographic analysis enabled the positions of the individual electrodes to be measured, both longitudinally and laterally. This paper presents additional results and an in-depth analysis of the data, supported by psychophysical findings in subjects with straight arrays. It also introduces a model which describes the effect of distance from the modiolus on the loudness growth function.
  • Item
    Thumbnail Image
    Musical timbre perception investigated using forward-masking
    Stainsby, Thomas H. ; McDermott, Hugh J. ; McKay, Colette M. ; Clark, Graeme M. ( 1999)
    There is growing general interest in the perception of musical sounds by cochlear implantees. This study was aimed at the perception of one specific aspect of musical timbre, the shape of steady-state frequency spectra. The relationship of the physical and internal spectral shapes was investigated using a forward-masking technique. In addition, the ability of subjects to identify and discriminate selected musical sounds was tested in two related experiments.
  • Item
    Thumbnail Image
    Testing of thin-film electrode arrays for cochlear implants of the future
    Parker, J. R. ; Duan, Y. Y. ; Patrick, J. ; Harrison, H. B. ; Reinhold, O. ; Clark, Graeme M. ( 1999)
    The Nucleus cochlear implant has been shown to give substantial communication benefit to the severe to profoundly deaf. Future cochlear implants will incorporate an advanced multi-channel electrode array, which will enable better sound-coding strategies to be implemented. This new electrode array will be fabricated using state-of-the-art micromachining technology. Any long-term implanted device such as a cochlear implant must undergo rigorous testing to ensure biological safety. In this paper four tests for the micromachined array are discussed. The tests are based on electrochemical methods, and include open circuit potential, galvanostatic biphasic pulse, 4-electrode shorting tests, and electrochemical impedance spectroscopy. This paper demonstrates that these test techniques are effective and informative in the development of thin-film electrode arrays. They can be used to verify the fabrication steps, electrode quality, and the suitability for the biological environment.
  • Item
    Thumbnail Image
    Benefits of pre-curved electrode arrays for the Nucleus multichannel cochlear implant [Abstract]
    Pyman, B. ; Clark, Graeme M. ; Saunders, Elaine ; Cohen, Lawrence T. ; Cowan, Robert S. C. ; Treaba, C. ; Dahm, M. ; Tykocinski, M. ( 1998)
    The purpose of the study was to evaluate whether placement of an electrode closer to the modiolus would provide a more efficient interface with the auditory nerve. A pre-curved, banded 22-electrode array has been developed. Following comprehensive safety studies, the array was inserted in three adult patients. Detailed x-ray analyses have been conducted to specify the positions of the electrode bands. Psychophysical studies have been conducted, within each subject, using electrodes which lie at differing distances from the modiolus. These studies have shown that as the distance from the modiolus decreased, electrode threshold currents decreased and dynamic ranges increased. Thresholds were lower than in a comparison group of standard array users. Forward masking studies showed current spread to be more focused at the electrodes lying closer to the modiolus. Electrode discrimination was also better at electrodes closer to the modiolus. JND for loudness, expressed as a function of dynamic range also decreased in this condition. Thus, a preliminary profile of the parameters of interest, for an improved implant design, suggest that an array which lies closer to the modiolus can result in lower current requirements and a more localised pattern of neural excitation.