    The Melbourne Cochlear Implant Clinic program
    Cowan, Robert S. C. ; Clark, Graeme M. (Singular Publishing, 1997)
    The Melbourne Cochlear Implant Clinic program involves a multidisciplinary clinical team, collaborating with those engaged in more fundamental research, and with the biomedical company Cochlear Limited. This chapter reflects the contributions of many professionals to managing children with cochlear implants.
  • Item
    Thumbnail Image
    Speech perception in implanted children: influence of preoperative residual hearing on outcomes [Abstract]
    Cowan, R. S. C. ; Barker, E. J. ; Pegg, P. ; Dettman, S. ; Rennie, M. ; Galvin, K. ; Meskin, T. ; Rance, G. ; Cody, K. ; Sarant, J. ; Larratt, M. ; Latus, K. ; HOLLOW, RODNEY ; Rehn, C. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1998)
    Since the first child was implanted with the Nucleus 22-channel prosthesis in Melbourne in 1985, several thousand children world-wide have now benefitted from this technology. More effective paediatric assessment and management procedures have now been developed, allowing cochlear implants to be offered to children under the age of 2 years. Improvements in speech processing strategy have also been implemented in the Nucleus implant system, resulting in increased mean speech perception benefits for implanted adults. Although a range of performance on formal measures of hearing, speech or language has been reported for children using implants, results from the first decade of implant experience consistently show that significant benefits are available to children receiving their implant at an early age. Reported speech perception results for implanted children show that a considerable proportion (60%) of paediatric patients in the Melbourne and Sydney clinics are able to understand some open-set speech using electrical stimulation alone. These results, and the upward trend of mean speech perception benefits shown for postlinguistically deafened adults have raised questions as to whether severely, or severely-to-profoundly deaf children currently using hearing aids would in fact benefit more from a cochlear implant. To investigate the potential influence of the degree of preoperative residual hearing on postoperative speech perception, results for all implanted children in the Melbourne and Sydney cochlear implant programs were analysed. Results showed that as a group, children with higher levels of preoperative residual hearing were consistently more likely to achieve open-set speech perception benefits. Potential factors in this finding could be higher levels of ganglion cell survival or greater patterning of the auditory pathways using conventional hearing aids prior to implantation. Conversely, children with the least preoperative residual hearing were less predictable, with some children achieving open-set perception, and others showing more limited closed-set benefits to perception. For these children, it is likely that preoperative residual hearing is of less significance than other factors in outcomes.
  • Item
    Thumbnail Image
    Acquisition of a tactile-alone vocabulary by normally hearing users of the Tickle Talker
    Galvin, Karyn L. ; Blamey, Peter J. ; Oerlemans, Michael ; Cowan, Robert S. C. ; Clark, Graeme M. ( 1999)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    A modification of play audiometry to assess speech discrimination ability in severe-profoundly deaf 2- to 4-year-old children
    Dawson, P. W. ; Nott, P. E. ; Clark, Graeme M. ; Cowan, Robert S. C. ( 1998)
    Objective: The aim was to develop an assessment procedure that was independent of language and speech production ability, to test speech feature discrimination severe-profoundly deaf children 2 to 4 yr of age. Design: The procedure being trialled was adapted from existing procedures. The child was required to respond with a game-like motor response to a “change” in a speech stimulus that was being presented repeatedly through a speaker. The change occurred at randomly determined times, and false alarm responses were measured during the waiting periods (while the child waited for the change). Two- to four-yr-old normally hearing children and hearing-impaired children using hearing aids and a group of 4-yr-old hearing-impaired children using cochlear implants were assessed on the task. Results: More than 82% of the 3- and 4-yr-old normally hearing and hearing-impaired children were able to complete the testing for the eight speech sound contrasts within three 20 minute sessions. Fifty percent of the 2-yr-old normally hearing and hearing-impaired children were able to condition and complete the task. All of the normally hearing children who completed the task successfully discriminated all speech sound contrasts. The performance of the hearing-impaired children using hearing aids was influenced by the degree of hearing loss and the type of speech contrast being tested. Similarly, the average performance of the children using cochlear implants was better for easier contrasts such as /ba/bi/ with contrasting vowel formant cues. Conclusions: This procedure has potential for use as a reliable clinical and research tool for assessing the development of auditory discrimination ability in 2- to 4-yr-old severe-profoundly deaf children.
  • Item
    Thumbnail Image
    A comparison of Tactaid II+ and Tactaid 7 use by adults with a profound hearing impairment
    Galvin, Karyn L. ; Mavrias, Gina ; Moore, Alessandra ; Cowan, Robert S. C. ; Blamery, Peter J. ; Clark, Graeme M. ( 1999)
    Objective: To evaluate and compare use of the Tactaid II+ and the Tactaid 7, in terms of speech perception, by adults with a hearing impairment. Design: Eight adults used one device daily for approximately 10 wk and attended seven training sessions. Performance was measured with tests of phonetic contrast perception, closed-set vowel and consonant identification, word and phoneme recognition in monosyllabic word lists, word recognition in sentences and speechtracking rate. A questionnaire was also administered. The protocol was repeated with the alternative device. Results: With each device, the group discriminated most phonetic contrasts at better-than-chance levels and demonstrated somewhat enhanced visual or auditory-visual perception when measured in terms of vowel identification, monosyllabic word recognition and speechtracking rate. An increase in speechtracking rate was also demonstrated for some individuals. Subjects generally reported little subjective improvement in speech perception and production, but were satisfied with the physical attributes of each device. Five of six subjects preferred the Tactaid 7. Conclusions: The Tactaid II+ and the Tactaid 7 provided suprasegmental and segmental information, enabling the group to discriminate phonetic contrasts and improve their perception of some speech materials. No consistent advantage was found for either device, thought most subjects preferred the Tactaid 7. Alternatives likely to provide a greater benefit to communication should be considered before Tactaid fitting.
  • Item
    Thumbnail Image
    Multichannel auditory brainstem implants: an Australian case study [Abstract]
    Hollow, Rod ; COWAN, ROBERT ; BRIGGS, ROBERT ; KAYE, ANDREW ; DOWELL, RICHARD ; Shaw, Stephanie ; Clarke, Graeme M. ( 1996)
    The multichannel Auditory Brainstem Implant (ABI) is an implantable device designed to restore a level of auditory perception in patients with bilateral acoustic neuromas, where the removal of the tumours is expected to result in a total loss of hearing. As with the cochlear implant, the ABI utilises an externally worn speech processor and headset, together with a surgically-placed receiver-stimulator and electrode array. The electrode array, developed through the collaboration of the House Ear Institute in the United States and Cochlear Corporation, consists of eight electrodes on a carrier, which is placed on the surface of the brainstem in the area of the cochlear nucleus.
  • Item
    Thumbnail Image
    A training program for use with multichannel speech perception/production tactile devices [Abstract]
    GALVIN, KARYN ; COWAN, ROBERT ; Mavrias, Gina ; Moore, Alessandra ; SARANT, JULIA ; Clark, Graeme M. ( 1996)
    Over the past ten years, there have been remarkable improvements in both conventional hearing aid technology and in the use of multichannel cochlear prostheses. These developments have resulted in improved speech perception for severely and profoundly hearing impaired adults and children. However, a small number of adults and children remain unable to benefit from either of these prosthetic approaches. This may occur as a result of medical/surgical issues, which render implantation unfeasible, or from a decision by the patient or parents that the device is inappropriate for the individual person. In these cases, use of a supplemental speech perception device employing the intact tactile modality has been advocated. A number of single and multichannel devices have been developed, both commercially and in the laboratory. One of these, the Tickle Talker, a multichannel electrotactile speech processor, has been developed and thoroughly evaluated with both adults and children at the University of Melbourne. Benefits to speech perception have been noted on both closed-set phonemic discrimination tests, and on open-set word and sentence scores, where the device was used to supplement lipreading and/or aided residual hearing. Benefits to articulation have also been noted. Recently, improved speech processing and the design of a new electrode handset have been implemented. While these factors are important to device acceptance, the critical factor in improving speech perception and production appears to be the training program which is employed with the device. The program must be based on the information available through the device, but organised to emphasize the integration of tactually-encoded speech information into open-set understanding of words and sentences if communication is to be improved. The important elements of the program will be discussed. At present, no tactile device is able to provide sufficient information for open-set speech understanding using only the tactile input. While this may be an ultimate goal, significant periods of training may be required to achieve this outcome.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users
    Dawson, P. W. ; Blamey, P. J. ; Dettman, S. J. ; Rowland, L. C. ; Barker, E. J. ; Tobey, E. A. ; Busby, P. A. ; Cowan, R. C. ( 1995)
    Objective: The aim was to assess articulation and speech intelligibility over time in a group of cochlear implant users implanted at 8 yr or over. The hypothesis was that the postoperative speech production performance would be greater than the preoperative performance. Design: A test of intelligibility using sentences and an articulation test measuring non-imitative elicited speech were administered to 11 and 10 subjects, respectively, who were implanted with the 22-electrode cochlear implant. Nine subjects received both tests. Age at implantation ranged from 8 yr to 20 yr and implant use ranged from 1 yr to 4 yr 5 mo. Results: For both the intelligibility and articulation tests roughly half of the subjects showed significant improvements over time and group mean postoperative performance significantly exceeded preoperative performance. Improvements occurred for front, middle, and back consonants; for stops, fricatives, and glides and for voiceless and voiced consonants. Conclusions: Despite being deprived of acoustic speech information for many childhood years, roughly half of the patients assessed showed significant gains in speech intelligibility and articulation postimplantation. The lack of a control group of non-implanted patients means that we cannot separate out the influence of the implant on speech production from other influences such as training and tactile-kinaesthetic feedback.
  • Item
    Thumbnail Image
    Speech perception for children with different levels of residual hearing using the cochlear 22-channel cochlear prosthesis [Abstract[
    Cowan, R. S. C. ; Galvin, K. L. ; Barker, E. J. ; Del Dot, J. ; Sarant, J. Z. ; Dettman, S. ; Hollow, R. ; Herridge, S. ; Rance, G. ; Larratt, M. ; Skok, M. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1996)
    Over the past 10 years, since the implantation of the first children with the Nucleus 22-channel cochlear prosthesis in Melbourne, the number of profoundly deaf children using this implant system has rapidly expanded. Longer-term experience with implanted children has led to improvements in paediatric assessment and management. Speech processing strategies have also been improved, resulting in a series of increases in speech perception benefits. Results of comparative studies of Speak and Multipeak speech processing strategies have shown that open-set word and sentence scores for a group of thirteen children evaluated over a two year period showed an advantage with the Speak speech processing strategy. The increases were noted particularly in speech perception in poor signal-to-noise conditions. Analysis has shown that consonant perception was significantly increased, due to an improved place perception. Given current speech perception scores for implanted children, it has been suggested that severely-to-profoundly deaf children currently using hearing aids could in fact benefit more from a cochlear implant. Preliminary investigation of results for children in the Melbourne and Sydney cochlear implant programs has shown that children with higher levels of preoperative residual hearing as a group do score significantly on open-set word and sentence perception tests using the implant alone. In children with lower levels of residual hearing, results were variable across the group.
  • Item
    Thumbnail Image
    The progress of children using the multichannel cochlear implant in Melbourne
    Cowan, R. S. C. ; Dowell, R. C. ; Hollow, R. ; Dettman, S. J. ; Rance, G. ; Barker, E. J. ; Sarant, J. Z. ; Galvin, K. L. ; Webb, R. C. ; Pyman, B. C. ; Cousins, V. C. ; Clark, Graeme M. ( 1995)
    Multi-channel cochlear implantation in children began in Australia in 1985 and there are now close to 4000 profoundly deaf children and adolescents using the Australian implant system around the world. The aim of the implant procedure is to provide adequate hearing for speech and language development through auditory input. This contrasts with the situation for adults with acquired deafness where the cochlear implant aims to restore hearing for someone with well-developed auditory processing and language skills. As with adults, results vary over a wide range for children using the Multi-channel implant. Many factors have been suggested that may contribute to differences in speech perception for implanted children. In an attempt to better understand these factors, the speech perception results for children implanted in Melbourne were reviewed and subjected to statistical analysis. This has indicated that the amount of experience with the implant and the length of sensory deprivation are strongly correlated with perceptual results. This means that younger children are likely to perform better with an implant and that a number of years of experience are required for children to reach their full potential. The results have also indicated that educational placement and management play a crucial role in children reaching their potential. Overall, 60% of the children and adolescents in the study have reached a level of open-set speech understanding using the cochlear implant without lipreading.