Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 13
  • Item
    Thumbnail Image
    Hearing restoration with the multichannel auditory brainstem implant
    Briggs, R. J. S. ; Kaye, A. H. ; Dowell, R. C. ; Hollow, R. D. ; Clark, Graeme M. ( 1997)
    Restoration of useful hearing is now possible in patients with bilateral acoustic neuromas by direct electrical stimulation of the cochlear nucleus. Our first experience with the Multichannel Auditory Brainstem Implant is reported. A forty four year old female with bilateral acoustic neuromas and a strong family history of Neurofibromatosis Type II presented with profound bilateral hearing impairment. Translabyrinthine removal of the right tumour was performed with placement of the Nucleus eight electrode Auditory Brainstem Implant. Intraoperative electrically evoked auditory brainstem response monitoring successfully confirmed placement over the cochlear nucleus. Postoperatively, auditory responses were obtained on stimulation of all electrodes with minimal non-auditory sensations. The patient now receives useful auditory sensations using the "SPEAK" speech processing strategy. Auditory brainstem Implantation should be considered for patients with Neurofibromatosis Type II in whom hearing preservation tumour removal is not possible.
  • Item
    Thumbnail Image
    Clinical findings for a group of infants and young children with auditory neuropathy
    RANCE, GARY ; Beer, David E. ; Cone-Wesson, Barbara ; Shepherd, Robert K. ; Dowell, Richard C. ; King, Alison M. ; Rickards, Field W. ; Clark, Graeme M. ( 1999)
    Objective: To examine the prevalence of auditory neuropathy in a group of infants at risk for hearing impairment and to present an overview of the clinical findings for affected children. Design: Results for 20 subjects who showed repeatable cochlear microphonic potentials in the absence of click-evoked auditory brain stem responses are included in this study. Behavioral and steady state evoked potential thresholds were established in each case. Where possible, otoacoustic emission and speech perception results (unaided and aided) also were obtained. Results: One in 433 (0.23%) of the children in our series had evidence of auditory neuropathy. The audiometric findings for these subjects varied significantly, with behavioural thresholds ranging from normal to profound levels. Discrimination skills were also variable. Approximately half of the subjects showed little understanding, or even awareness, of speech inputs in both the unaided and aided conditions. There were, however, a number of children who could score at significant levels on speech discrimination tasks and who benefited from the provision of amplification. Conclusion: The results suggest that auditory neuropathy is more common in the infant population than previously suspected. The effects of neuropathy on auditory function appear to be idiosyncratic, producing significant variations in both the detection and discrimination of auditory signals. As such, the management of children with this disorder must allow for individual differences.
  • Item
    Thumbnail Image
    Aided speech recognition abilities of adults with a severe or severe-to-profound hearing loss
    Flynn, Mark C. ; Dowell, Richard C. ; Clark, Graeme M. ( 1998)
    Adults with severe or severe-to-profound hearing losses constitute between 11% and 13.5% of the hearing impaired population. A detailed investigation of the speech recognition of adults with severe (n = 20) or severe-to-profound (n = 14) hearing loss was conducted at The University of Melbourne. Each participant took part in a series of speech recognition tasks while wearing his or her currently fitted hearing aid(s). The assessments included closed-set tests of consonant recognition and vowel recognition, combined with open-set tests of nonosyllabic word recognition and sentence recognition. Sentences were presented in quiet listening conditions. Although the results demonstrated wide variability in performance, some general trends were observed. As expected vowels were generally well perceived compared with consonants. Monosyllabic word recognition scores for both the adults with a severe hearing impairment (M = 67.2%) and the adults with a severe-to profound hearing impairment (M = 38.6%) could be predicted from the segmental tests, with an allowance for lexical effects. Scores for sentences presented in quiet showed additional linguistic effects and a significant decrease in performance with the addition of background noise (from 82.9% to 74.1% for adults with a severe hearing loss and from 55.8% to 34.2% for adults with a severe-to-profound hearing loss). Comparisons were made between the participants and a group of adults using a multiple-channel cochlear implant. This comparison indicated that some adults with a severe or severe-to-profound hearing loss may benefit from the use of a cochlear implant. The results of this study support the contention that cochlear implant candidacy should not rely solely on audiometric thresholds.
  • Item
    Thumbnail Image
    Steady-state evoked potential and behavioural hearing thresholds in a group of children with absent click-evoked auditory brain stem response
    RANCE, GARY ; Dowell, Richard C. ; Rickards, Field W. ; Beer, David E. ; Clark, Graeme M. ( 1998)
    Objective: 1) To examine the distribution of behavioural hearing thresholds in a group of children who had shown no click-evoked auditory brain stem response (ABR) at maximum presentation levels. 2) To describe the relationship between the 90 Hz steady-state evoked potential (SSEP) and behavioural thresholds in these subjects. Design: A retrospective study based on clinical findings obtained from 108 infants and young children. Each of these children had shown no recordable ABR to clicks presented at maximum levels (100 dB nHL). SSEP audiograms were obtained using AM/FM tones at the octave frequencies 250 to 4000 Hz. The results of these evoked potential assessments were compared with hearing thresholds established behaviourally. Results: Click-ABR assessment could not differentiate between the subjects in our sample with total hearing losses and those with useful residual hearing. Although some of the ears were anacusic, more than a quarter showed residual hearing ate each of the audiometric frequencies. Furthermore, at least 10% of the behavioural thresholds at each frequency fell within the moderate/severe hearing loss range. A far closer relationship was observed between SSEP and hearing thresholds. On occasions where the SSEP was absent at maximum levels, 99.5% of the ears showed either a total loss or a behavioural threshold within 10 dB of that level. When an SSEP was obtained, the hearing threshold was typically within 5 dB of the SSEP threshold. Conclusion: The results suggested that in our group of selected subjects, the SSEP technique was able to assess ears with only minimal amounts of residual hearing. Where the brevity of the acoustic click limits both its frequency specificity and its presentation level, the modulated tones used for SSEP testing allow accurate, frequency-specific assessment at high presentation levels.
  • Item
    Thumbnail Image
    The progress of children using the multichannel cochlear implant in Melbourne
    Cowan, R. S. C. ; Dowell, R. C. ; Hollow, R. ; Dettman, S. J. ; Rance, G. ; Barker, E. J. ; Sarant, J. Z. ; Galvin, K. L. ; Webb, R. C. ; Pyman, B. C. ; Cousins, V. C. ; Clark, Graeme M. ( 1995)
    Multi-channel cochlear implantation in children began in Australia in 1985 and there are now close to 4000 profoundly deaf children and adolescents using the Australian implant system around the world. The aim of the implant procedure is to provide adequate hearing for speech and language development through auditory input. This contrasts with the situation for adults with acquired deafness where the cochlear implant aims to restore hearing for someone with well-developed auditory processing and language skills. As with adults, results vary over a wide range for children using the Multi-channel implant. Many factors have been suggested that may contribute to differences in speech perception for implanted children. In an attempt to better understand these factors, the speech perception results for children implanted in Melbourne were reviewed and subjected to statistical analysis. This has indicated that the amount of experience with the implant and the length of sensory deprivation are strongly correlated with perceptual results. This means that younger children are likely to perform better with an implant and that a number of years of experience are required for children to reach their full potential. The results have also indicated that educational placement and management play a crucial role in children reaching their potential. Overall, 60% of the children and adolescents in the study have reached a level of open-set speech understanding using the cochlear implant without lipreading.
  • Item
    Thumbnail Image
    Vowel imitation task: results over time for 28 cochlear implant children under the age of eight years
    Dettman, S. J. ; Barker, E. J. ; Dowell, R. C. ; Dawson, P. W. ; Blamey, P. J. ; Clark, Graeme M. ( 1995)
    With increasing numbers of implanted children under the age of 4 years, numerous researchers have reminded us of the need for valid, sensitive, and reliable tests of developing speech perception.1,2 In addition to studies of the efficacy of implanted prostheses, there is a need to investigate the many variables that influence children's communicative performance, such as changes in speech-coding strategy, updated speech-processing systems, the effects of various training regimens, and the selection of educational and communication modes.
  • Item
    Thumbnail Image
    The development of the Melbourne/Cochlear multiple-channel cochlear implant for profoundly deaf children
    Clark, Graeme M. ; Busby, Peter A. ; Dowell, Richard C. ; Dawson, Pamella W. ; Pyman, Brian C. ; Webb, Robert L. ; Staller, Steven J. ; Beiter, Anne L. ; Brimacombe, Judith A. ( 1992)
    In 1978-79, a speech processing strategy which extracted the voicing (FO) and second formant (F2) frequencies and presented these as rate and place of stimulation respectively to residual auditory nerve fibres was developed for the University of Melbourne's prototype multiple-channel receiver-stimulator (Clark et aI1977, Clark et a11978, Tong et aI1980). This speech processing strategy was shown to provide post linguistically deaf adults with some open-set speech comprehension using electrical stimulation alone, and considerable help when used in combination with lipreading (Clark et al 1981).
  • Item
    Thumbnail Image
    Speech perception, production and language results in a group of children using the 22-electrode cochlear implant
    Blamey, P. J. ; Dawson, P. W. ; Dettman, S. J. ; Rowland, L. C. ; Brown, A. M. ; Busby, P. A. ; Dowell, R. C. ; Rickards, F. W. ; Clark, Graeme M. ( 1992)
    Five children out of a group of nine (aged 5.5 to 19.9 years) implanted with the 22-electrode cochlear implant (Cochlear Ply. Ltd.) have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores for monosyllabic words ranged from 40% to 72%. Word scores in sentences ranged from 26% to 74%. Four of these five children were implanted during preadolescence. The fifth child, who had a progressive loss and was implanted during adolescence after a short period of very profound deafness, scored highest on all speech perception tests. The remaining four children who did not demonstrate open-set recognition were implanted during adolescence after a long duration of profound deafness. Post-operative performance on closed-set speech perception tests was better than pre-operative performance for all children. Improvements in speech and language assessments were also noted. These improvements tended to be greater for the younger children. The results are discussed with reference to variables which may contribute to successful implant use: such as age at onset, duration of profound hearing loss, age at implantation, aetiology, educational program, and the type of training provided.
  • Item
    Thumbnail Image
    The effects of auditory feedback from the nucleus cochlear implant on the vowel formant frequencies produced by children and adults
    Richardson, Louise M. ; Busby, Peter A. ; Blamey, Peter J. ; Dowell, Richard C. ; Clark, Graeme M. ( 1993)
    Cochlear implants provide an auditory signal with which profoundly deaf users may monitor their own speech production. The vowel production of two adults and three children who used the Nucleus multiple-electrode cochlear implant was examined to assess the effect of altered auditory feedback. Productions of words were recorded under conditions where the talkers received auditory feedback (speech processor turned on) and where no auditory feedback was provided (speech processor turned off). Data were collected over 3 days at weekly intervals. First and second formant frequencies were measured and the data were analysed to assess significant differences between auditory feedback conditions, vowel context, and data collection points. Overall, the results varied across talkers, across the data collection days, and depended on the consonant environment of the vowel. However, two effects of auditory feedback were noted. First, there was a generalized shift in first formant frequencies between the processor on and processor off conditions across three of the five subjects, but the shift differed in direction for each subject. Second, for three of the five talkers, the two front vowels /ε/ and /I/ were more neutralised in the absence of auditory feedback. However, this effect was less pronounced than that noted by previous studies.
  • Item
    Thumbnail Image
    Cochlear implants in children, adolescents, and prelinguistically deafened adults: speech perception
    Dawson, Pam W. ; Blamey, Peter J. ; Rowland, Louise C. ; Dettman, Shani J. ; Clark, Graeme M. ; Busby, Peter A. ; Brown, Alison M. ; Dowell, Richard C. ; Rickards, Field W. ( 1992)
    A group of 10 children, adolescents, and prelinguistically deafened adults were implanted with the 22-electrode cochlear implant (Cochlear Ply Ltd) at the University of Melbourne Cochlear Implant Clinic and have used the prosthesis for periods from 12 to 65 months. Postoperative performance on the majority of closed-set speech perception tests was significantly greater than chance, and significantly better than preoperative performance for all of the patients. Five of the children have achieved substantial scores on open-set speech tests using hearing without lipreading. Phoneme scores in monosyllabic words ranged from 30% to 72%; word scores in sentences ranged from 26% to 74%. Four of these 5 children were implanted during preadolescence (aged 5:5 to 10:2 years) and the fifth, who had a progressive loss, was implanted during adolescence (aged 14:8 years). The duration of profound deafness before implantation varied from 2 to 8 years. Improvements were also noted over postoperative data collection times for the younger children. The remaining 5 patients who did not demonstrate open-set recognition were implanted after a longer duration of profound deafness (aged 13:11to 20:1 years). The results are discussed with reference to variables that may affect implant performance, such as age at onset of loss, duration of profound loss, age at implantation, and duration of implantation. They are compared with results for similar groups of children using hearing aids and cochlear implants.