    Cochlear implants in adults and children: comment
    Clark, Graeme M. ( 1997)
    This is a well-written review of the NIH Consensus report on cochlear implants for adults and children.
  • Item
    Thumbnail Image
    Pitch and loudness estimation for single and multiple pulse per period electric pulse rates by cochlear implant patients
    Busby, P. A. ; Clark, Graeme M. ( 1997)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Cochlear implants in the third millennium
    Clark, Graeme M. ( 1999)
    This article discusses the specific challenges facing cochlear implantation in the Third Millennium.
  • Item
    Thumbnail Image
    Gap detection by early-deafened cochlear-implant subjects
    Busby, P. A. ; Clark, Graeme M. ( 1999)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve using non-charge-balanced stimuli
    Shepherd, Robert K. ; Linahan, N. ; Xu, J. ; Clark, Graeme M. ; Araki, S. ( 1999)
    This study was designed to evaluate the pathophysiological response of the cochlea following long-term intracochlear electrical stimulation using a poorly charge-balanced stimulus regime, leading to direct current (DC) levels >0.1 µA. Four normal-hearing adult cats were bilaterally implanted with scala tympani electrode arrays and unilaterally stimulated for periods up to 2200 h. Stimuli consisted of 50 µs monophasic current pulses presented at 2000 pulses per second (pps) per channel, and resulted in DC levels of 0.4-2.8 µA. Both acoustic and electrical (EABR) evoked potentials were periodically recorded during the stimulation program. Frequency-specific stimuli indicated that an extensive and widespread hearing loss occurred over the 4-24 KHz region in all stimulated cochleae, although the 2 KHz region exhibited thresholds close to normal in some animals, despite long-term implantation and chronic stimulation. Longitudinal EABRs showed a statistically significant increase in threshold for three of the four animals. Histopathological evaluation of the cochleae revealed a highly significant reduction in ganglion cell density in stimulated cochleae compared with their controls. Spiral ganglion cell loss was significantly correlated with the degree of inflammation, duration of electrical stimulation, and the level of DC. In conclusion, the present study highlights the potential for neural damage following stimulation using poorly charge-balanced stimuli.
  • Item
    Thumbnail Image
    Research advances for cochlear implants
    Clark, Graeme M. ( 1998)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Aided speech recognition abilities of adults with a severe or severe-to-profound hearing loss
    Flynn, Mark C. ; Dowell, Richard C. ; Clark, Graeme M. ( 1998)
    Adults with severe or severe-to-profound hearing losses constitute between 11% and 13.5% of the hearing impaired population. A detailed investigation of the speech recognition of adults with severe (n = 20) or severe-to-profound (n = 14) hearing loss was conducted at The University of Melbourne. Each participant took part in a series of speech recognition tasks while wearing his or her currently fitted hearing aid(s). The assessments included closed-set tests of consonant recognition and vowel recognition, combined with open-set tests of nonosyllabic word recognition and sentence recognition. Sentences were presented in quiet listening conditions. Although the results demonstrated wide variability in performance, some general trends were observed. As expected vowels were generally well perceived compared with consonants. Monosyllabic word recognition scores for both the adults with a severe hearing impairment (M = 67.2%) and the adults with a severe-to profound hearing impairment (M = 38.6%) could be predicted from the segmental tests, with an allowance for lexical effects. Scores for sentences presented in quiet showed additional linguistic effects and a significant decrease in performance with the addition of background noise (from 82.9% to 74.1% for adults with a severe hearing loss and from 55.8% to 34.2% for adults with a severe-to-profound hearing loss). Comparisons were made between the participants and a group of adults using a multiple-channel cochlear implant. This comparison indicated that some adults with a severe or severe-to-profound hearing loss may benefit from the use of a cochlear implant. The results of this study support the contention that cochlear implant candidacy should not rely solely on audiometric thresholds.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: I. Effect on residual hearing [Abstract]
    Xu, J. ; Shepherd, R. K. ; Clark, Graeme M. ( 1996)
    In addition to direct excitation of auditory nerve fibres, cochlear implant patients with small amounts of residual hearing may receive important additional auditory cues via electrophonic activation of hair cells 1. Before incorporating electrophonic hearing into speech processing strategies, the extent of hair cell survival following cochlear implantation must first be determined. We have recently demonstrated widespread survival of hair cells apical to electrode arrays implanted for periods of up to three years, the present report describes the effects of chronic electrical stimulation on hair cell survival.
  • Item
    Thumbnail Image
    Chronic electrical stimulation of the auditory nerve at high rates: II. Cochlear pathophysiology [Abstract]
    Shepherd, R. K. ; Xu, J. ; Clark, Graeme M. ( 1996)
    A major factor in the improved performance of cochlear implant patients has been the use of high stimulus rate speech processing strategies. While these strategies show clear clinical advantage, we know little of their long-term safety. Indeed, recent studies have indicated that high stimulus rates at intensities above clinical limits, can result in neural damage as a result of prolonged neuronal hyperactivity. The present study was designed to evaluate the effects of chronic electrical stimulation of the auditory nerve at high rates, using intensities within clinical limits.
  • Item
    Thumbnail Image
    Spatial representation of the cochlea within the inferior colliculus of neonatally deafened kittens following chronic electrical stimulation of the auditory nerve [Abstract]
    Shepherd, R. K. ; Martin, R. L. ; Brown, M. ; Clark, Graeme M. ( 1995)
    The orderly tonotopic representation of the cochlea is accurately reproduced within the central auditory system of normal hearing animals. Any degradation of this representation as a result of a neonatal hearing loss or chronic electrical stimulation during development could have important implications for the use of multichannel cochlear implants in young children. In the present study we have used 2-deoxyglucose autoradiography (2-00) to examine the topographic representation of the cochlea within the inferior colliculus (IC) of neonatally deafened kittens following periods of chronic intracochlear electrical stimulation.