Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 29
  • Item
    Thumbnail Image
    Training place pitch perception in cochlear implant users [Abstract]
    Dawson, Pam ; Clark, Graeme M. ( 1997)
    The study has aimed at determining whether the ability to use place coded vowel formant information could be enhanced with analytical vowel training in a group of -congenitally deafened patients, who showed limited speech perception skills after cochlear implant experience ranging from 1y8m to 6y11m. It has investigated whether improvements in vowel perception after training can carry over to word recognition. A further objective was to see whether poorer vowel perception was associated with poorer electrode position difference limens. Three children, one adolescent and one young adult were assessed with synthesized versions of the words /hid, head, had, hud, hod, hood/ and a natural version of these words as well as with a closed-set monosyllabic word task. The change in performance after 10 training sessions was compared to the change in performance during a non-training period. Four of the five patients showed a significant gain in synthetic vowel perception post-training on at least one assessment, but only two patients showed gains across a number of tests post-training. For one of these 2 children improvements in vowel perception generalized to word perception. Patients’ electrode limens ranged from 1 to 3 electrodes except for 1 adolescent whose minimal progress post-training could be partly explained by poorer apical electrode discrimination. The findings are discussed with reference to a number of factors, including the notion of a "critical period" for neural plasticity.
  • Item
    Thumbnail Image
    Auditory processing abilities in children using cochlear implants: their relevance to speech perception [Abstract]
    Dawson, Pam W. ; McKay, Colette M. ; Busby, Peter A. ; Grayden, David B. ; Clark, Graeme M. ( 1999)
    This study aimed to investigate the relationships between some basic auditory processing skills, subject variables and speech perception ability in young children using cochlear implants. A modification of the play audiometry procedure was used to measure electrode discrimination and "rate-of-processing" ability in seventeen 4-10 year old children. In the electrode discrimination task, children responded with a game-like motor response when a repeating stimulation on a reference electrode "changed" to a different electrode. In the "rate-of processing" task, children had to respond to the "change" to a different electrode, when the duration of the stimuli and the time interval between the stimuli were decreased. Normally hearing children were assessed on this task with acoustic stimulation. Nonverbal intelligence, speech feature discrimination and closed-set word recognition were also measured in the children using implants.
  • Item
    Thumbnail Image
    Speech perception & indirect benefits for severely hearing impaired children using cochlear implants [Abstract]
    Cowan, Robert S. C. ; Dowell, Richard C. ; Nott, P. ; Rennie, Maree ; Pyman, B. ; Clark, Graeme M. ( 1998)
    The benefits to speech perception, speech production, communication, and quality of life were investigated for severely hearing impaired children using cochlear implants and hearing aids. For the youngest children, assessments of psychological status, and use of a battery of cognitive and language tests were important factors in determining performance benefits prior to the child developing speech. For older children, the effects of increased one-to-one oral habilitation, and systematic encouragement of parental involvement were also investigated. Results suggested that parental support for consistent device use was an important factor in producing outcomes. Children with residual hearing were more likely to achieve open-set perception. Each child was also assessed for changes in quality of life, through use of a standardized health utility instrument. Results from the group were collated, and teamed with a costing assessment for the procedure, which allowed a complete cost-utility analysis to be completed. Results suggested that indirect benefits, such as the effects on speech production, usual activities, lower concentration, and less distress were ranked as more important than changes to hearing in a number of the children. Costs per QALY were consistent with those reported in the literature, and suggested that the cochlear implant is highly cost-effective as a medical technology.
  • Item
    Thumbnail Image
    Evaluation of direct and indirect benefits in the selection of cochlear implant candidates [Abstract]
    Cowan, Robert S. C. ; Dowell, Richard C. ; Hollow, Rod ; Dettman, Shani J. ; Clark, Graeme M. ( 1998)
    The value of cochlear implants as an established clinical option for profoundly hearing-impaired adults and children has been supported by significant research results over a number of years which clearly established the benefits available (U.S. National Institutes of Health Consensus Statement 1995). Benefit has traditionally been considered as the impact of the cochlear implant procedure on hearing, and in the case of children, on the use of that hearing to develop speech and language. However, as a result of continuing research, improvements have been realised both in hardware and speech processing. As a direct consequence of these improvements, the mean open-set implant-alone speech perception scores for implanted adults have continued to increase. In response to the increased mean scores shown by adult cochlear implant users in quiet, perception tests in background noise are now being used as a direct measure of the potential benefits of cochlear implants available to severely-to-profoundly hearing-impaired candidates. In addition, consideration in candidature should also be given to indirect benefits, such as reduction in the stress. of listening and lipreading, improved performance at work, enhanced opportunity to maintain or in children to develop speech which is understandable to the general community, and the social effects of reducing the isolating effects of profound deafness. Measurement of indirect benefit can be combined with a costing study, enabling evaluation of the implant procedure from a cost-utility standpoint, and comparison of outcomes using other technologies such as hearing aids. The use of new approaches to candidature, including new measures of direct and indirect benefit is reported using data from the Melbourne cochlear implant program.
  • Item
    Thumbnail Image
    An analysis of high rate speech processing strategies using the Nucleus 24 cochlear implant [Abstract]
    Vandali, A. E. ; Grayden, D. B. ; Whitford, L. A. ; Plant, K. L. ; Clark, Graeme M. ( 1998)
    The effects of varying the stimulation rate on speech perception was evaluated in five postlinguistically deaf adult users of the Nucleus 24 Cochlear Implant System. Three different rates of electrical stimulation, 250, 807, and 1615 pulses per second per channel were employed. For the high stimulus rate the analysis frequency was the same as for the medium rate condition. The study investigated the effect of varying rate of stimulation when using the electrode selection technique of the SPEAK strategy. The study used a repeated ABC experimental design, in order to account for learning effects and to minimize ordering effects. Speech perception was evaluated using both monosyllabic words (open-sets of CNC words in quiet) and sentence materials (open-sets of CUNY sentences at signal-to-noise ratios from +20 to 0dB). In addition, the subjects' perception of closed-sets of 19 vowels and 24 consonants, presented in the H/VID and A/C/A context, were also investigated. The recognition and perception of distinctive features were assessed across strategies and patients. Preliminary speech perception results have shown no statistically significant difference in performance between the low and medium stimulation rates. However, significantly poorer results were observed for the high rate condition for some tests with some individuals. Individual differences may be explained by the effects of rate of stimulation on speech features.
  • Item
    Thumbnail Image
    Factors influencing gap detection in children using cochlear implants [Abstract]
    Busby, P. A. ; Clark, Graeme M. ( 1998)
    Two studies on gap detection were conducted with children implanted with the Cochlear Limited multiple-electrode prosthesis. In the first study, gap thresholds were measured at three pulse rates (200, 500, and 1000 pulses/s) and two stimulus durations (500 and 1000 ms) in 15 subjects. Average gap thresholds ranged from 1.8 to 32.1 ms. There was, essentially, no effect of pulse rate and in all but two subjects, no effect of stimulus duration. For these two subjects, thresholds were higher for the 1000 ms stimulus duration. In the second study, the relationships between gap thresholds and subject characteristics, and between gap thresholds and speech perception scores were examined using data from 27 subjects. A significant negative correlation between age at onset of deafness and gap thresholds was found, indicating that subjects with an earlier onset of deafness had larger gap thresholds, and most of the variability in gap thresholds was found for the congenitally deaf subjects. Gap thresholds did not correlate with other subject variables, such as duration of deafness and duration of implant use. Significant negative correlations were found between gap thresholds and word scores for open-set BKB sentences in the auditory-visual condition and the lipreading enhancement scores for the same test, indicating that subjects with poorer gap thresholds had lower speech scores. Gap thresholds did not correlate with word scores for BKB sentences in the audition alone condition, and scores for closed-set monosyllabic word tests.
  • Item
    Thumbnail Image
    An analysis of high rate speech processing strategies using the Nucleus 24 cochlear implant [Abstract]
    Vandali, A. E. ; Grayden, D. B. ; Whitford, L. A. ; Plant, K. L. ; Clark, Graeme M. ( 1998)
    Speech comprehension for a group of five users of the Nucleus 24 Cochlear Implant system was explored at three rates of electrical stimulation, 250, 807, and 1615 pulses per second per channel. For the high stimulus rate the analysis frequency was the same as for the medium rate condition. The study investigated the effect of varying rate of stimulation when using the electrode selection technique of the SPEAK strategy. This has been undertaken using a repeated ABC experimental design to account for learning and minimize ordering effects. Speech perception was assessed using open-sets of CNC words in quiet and open-sets of CLTNY sentences at signal-to-noise ratios from +20 to 0dB. Closed-sets of 19 vowels and 24 consonants were also presented, in the H/V/D and A/C/A context. The recognition and perception of distinctive features were assessed across strategies and patients. Preliminary speech perception results have shown no statistically significant difference in performance between the low and medium stimulation rates. However, significantly poorer results were observed for the high rate condition for some tests. Individual differences may be explained by the effects of rate of stimulation on speech features.
  • Item
    Thumbnail Image
    Electrical stimulation of the auditory nerve: chronic monopolar stimulation using very high stimulus rates [Abstract]
    Tykocinski, M. ; Linahan, N. ; Shepherd, Robert K. ; Clark, Graeme M. ( 1998)
    Speech processing strategies based on high rate electrical stimulation have been associated with recent improvements of speech perception among cochlear implant users. In the present study we investigated the effects of chronic monopolar stimulation using very high rates (14493 pulses\s). Under general anaesthesia (ketamine (20 mg/kg) and xylazine (3.8 mg/kg) i.p.) six normal hearing cats were implanted bilaterally with a three channel platinum (Pt) scala tympani electrode array, while a return Pt-electrode was placed outside the bulla. Chronic electrical stimulation using charge-balanced biphasic current pulses was delivered unilaterally via a transcutaneous leadwire connected to a backpack-stimulator for up to 2000 h. The animals hearing status was periodically monitored using acoustically evoked compound action potentials (CAP's) and brainstem responses (ABR's). In addition the electrically evoked ABR (EABR) was also recorded to ensure that the chronic stimulus was above threshold. Stimulus current and electrode voltage waveforms were monitored twice daily and access resistance (Ra) and electrode impedance (Zc) calculated. ABR and CAP thresholds were elevated immediately following implantation, but generally showed evidence of partial recovery (0-40 dB). Further deterioration of thresholds on the stimulated side (10-30 dB) was subsequently observed, while control-thresholds remained more stable. Ra (1.3-1.8 kΩ) and Zc (2.2-3.8Ω) typically increased in the first few weeks of electrical stimulation up to Ra:5.6 kΩ and Zc:8.1 kΩ, before decreasing slightly to a constant plateau. These initial results indicate changes in the electrode-tissue interface and tissue growth within the cochlea. They also indicate that chronic stimulation at these high rates may decrease residual hearing.
  • Item
    Thumbnail Image
    Prediction of variance in neural response to cochlear implant stimulation and its implications for perception [Abstract]
    O'LEARY, STEPHEN ; Irlicht, Lawrence S. ; BRUCE, IAN ; White, Mark ; Clark, Graeme M. ( 1997)
    Cochlear implant patients' perception of sound is derived via electrical pulses arising from an electrode array. Chosen aspects of the acoustic spectrum are coded via a stimulation pattern designed according to some sound coding algorithm. Thus, a patients' ability to discriminate between sounds, and in turn their understanding, is directly related to their ability to differentiate between the patterns of electrical stimulation which code various sounds.
  • Item
    Thumbnail Image
    Current speech perception benefits for adults using the speak strategy with the nucleus 22-channel cochlear implant
    Hollow, R. D. ; Plant, K. ; Larrantt, M. ; Skok, L. ; Whitford, L. A. ; Dowell, R. C. ; Clark, Graeme M. ( 1997)
    Present day recipients of the Nucleus 22-channel cochlear implant make use of the SPEAK speech processing strategy in the Spectra 22 speech processor. Introduced in 1994, the SPEAK strategy is based upon research conducted at the University of Melbourne and the Bionic Ear Institute. This paper compares the pre-and post-operative speech perception abilities of adults who have used the SPEAK speech processing strategy since the 'start-up' of their cochlear implant system. Data was analysed from open-set sentence and word tests administered pre-operatively and at regular intervals postoperatively. Patients showed significant improvement in their ability to recognise speech, when listening with the cochlear implant without lipreading, within the first two weeks. Mean scores for open-set sentences were 15% preoperatively and 64% two weeks after initial programming.