  • Item
    Thumbnail Image
    The Contour electrode array: Safety study and initial patient trials of a new perimodiolar design
    Tykocinski, M ; Saunders, E ; Cohen, LT ; Treaba, C ; Briggs, RJS ; Gibson, P ; Clark, GM ; Cowan, RSC (LIPPINCOTT WILLIAMS & WILKINS, 2001-01)
    OBJECTIVE: The aim of these studies was to investigate the insertion properties and safety of a new intracochlear perimodiolar electrode array design (Contour). BACKGROUND: An electrode array positioned close to the neural elements could be expected to reduce stimulation thresholds and might potentially reduce channel interaction. METHODS: Two sequential studies were conducted. In study 1, the Contour electrode array was inserted in 12 human temporal bones. After cochlear surface preparation, the position of the array was noted and the basilar membrane was examined for insertion damage. On the basis of the outcome of this temporal bone study, study 2 investigated the Contour array, mounted on a Nucleus CI-24 M device and implanted in three adult patients. RESULTS: Study I showed that in 10 temporal bones, the Contour array was positioned close to the modiolus, and the basilar membrane was intact. In the two remaining bones, the arrays had pierced the basilar membrane and were positioned in the scala vestibuli apical to the penetration. Statistical analysis showed an equivalent probability of insertion-induced damage of the two array designs. In study 2, image analysis indicated that the Contour electrodes were positioned closer to the modiolus than the standard Nucleus straight array. Lower T and C levels, but higher impedance values, were recorded from electrodes close to the modiolus. Initial speech perception data showed that all patients gained useful open-set speech perception, two patients achieving scores of 100% on sentence material 3 months postoperatively. CONCLUSIONS: The temporal bone studies showed the Contour electrode array to be generally positioned closer to the modiolus than the standard Nucleus straight array, and to have an equivalent probability of causing insertion-induced damage.
  • Item
    Thumbnail Image
    Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    Cohen, LT ; Saunders, E ; Clark, GM (ELSEVIER SCIENCE BV, 2001-05)
    Psychophysical measurements were performed in three hearing-impaired adult subjects implanted with a CI22 cochlear prosthesis (Cochlear Ltd.) fitted with a developmental peri-modiolar electrode array. The array was manufactured with a curvature approximating that of the inner wall of the scala tympani but, after straightening and insertion, lay on average about half way between the inner and outer walls of the scala. All subjects were tested with bipolar stimulation; two were also tested with monopolar, employing the most basal electrode as the return. Maximum comfortable level and threshold reduced with decreasing distance of electrode from the modiolus, whereas dynamic range increased. The linearity of the loudness growth function did not vary significantly with electrode position but the function was more non-linear for lower maximum comfortable levels. Current level discrimination, normalized with respect to dynamic range, improved with decreasing distance of electrode from the modiolus in two subjects. Pitch varied regularly with insertion depth of the stimulated electrode for bipolar stimulation in two subjects and also for monopolar stimulation in one subject. Electrode discrimination was enhanced by closeness to the modiolus. Whereas the forward masking patterns for bipolar stimulation of electrodes close to the modiolus had a sharp double-peaked structure, those for monopolar stimulation were flatter and had a single peak.
  • Item
    Thumbnail Image
    Cochlear view: postoperative radiography for cochlear implantation
    XU, JIN ; Xu, Shi-Ang ; Cohen, Lawrence T. ; Clark, Graeme M. ( 2000)
    Objective: This study aimed to define a spatial position of the cochlea in the skull based on anatomical studies and to design an appropriate method of skull radiography for demonstration of the multichannel intracochlear electrode array and the structures of the inner ear, for use in evaluating the electrode position and its related pitch perception. Background: The conventional skull radiograph (plain radiograph)can offer a complete and direct image of an intracochlear electrode array, if the x-ray is directed to the cochlea and parallel to the axis of the cochlea. Methods: Measurement from computed tomography imaging and three-dimensional reconstruction were performed to define the spatial position of the cochlea in the skull. Results: A radiographic projection, the cochlear view, was designed. A detailed radiographic method and radiologic interpretation of the cochlear view is described. An improved clinical method for measuring the longitudinal and angular position of the electrodes from the cochlear view is recommended. Conclusions: The application of the cochlear view has proved that it is beneficial postoperatively in documenting the results of cochlear implantation, and in evaluating the depth of insertion and position of individual electrodes. It serves as a valuable reference for managing frequency mapping, optimizing speech processing strategies, and further research purposes. The method can be widely used in cochlear implant clinics because of its simplicity, low radiation, speed, and minimal cost.
  • Item
    Thumbnail Image
    Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
    TYKOCINSKI, MICHAEL ; Cohen, Lawrence T. ; Pyman, Brian C. ; Roland (Jr), Thomas ; Treaba, Claudiu ; PALAMARA, JOSEPH ; Dahm, Markus C. ; Shepherd, Robert K. ; XU, JIN ; Cowan, Robert S. ; Cohen, Noel L. ; Clark, Graeme M. ( 2000)
    Objective: This study was conducted to evaluate the insertion properties and intracochlear trajectories of three perimodiolar electrode array designs and to compare these designs with the standard Cochlear /Melbourne array. Background: Advantages to be expected of a perimodiolar electrode array include both a reduction in stimulus thresholds and an increase in dynamic range, resulting in a more localized stimulation pattern of the spiral ganglion cells, reduced power consumption, and, therefore, longer speech processor battery life. Methods: The test arrays were implanted into human temporal bones. Image analysis was performed on a radiograph taken after the insertion. The cochleas were then histologically processed with the electrode array in situ, and the resulting sections were subsequently assessed for position of the electrode array as well as insertion-related intracochlear damage. Results: All perimodiolar electrode arrays were inserted deeper and showed trajectories that were generally closer to the modiolus compared with the standard electrode array. However, although the precurved array designs did not show significant insertion trauma, the method of insertion needed improvement. After insertion of the straight electrode array with positioner, signs of severe insertion trauma in the majority o fimplanted cochleas were found. Conclusions: Although it was possible to position the electrode arrays close to the modiolus, none of the three perimodiolar designs investigated fulfilled satisfactorily all three criteria of being easy, safe, and a traumatic to implant.
  • Item
    Thumbnail Image
    Where to now? - Impact of New Technologies on use of cochlear implants
    Van Hoesel, R. ; Zhang, A. ; Tykocinski, M. ; Dham, M. ; Patrick, J. ; Parker, J. ; Clark, Graeme M. ; Cowan, R. S. C. ; Saunders, E. ; Vandali, A. E. ; Dowell, R. C. ; Treaba, C. ; Harrison, J. M. ( 2000)
    The history of cochlear implant use by adults and children with profound hearing loss although relatively short (20 some years), has been characterised by continual technological innovations which have enhanced the performance, packaging, and clinical use of these devices. In particular, the development of the Nucleus multiple channel cochlear implant has included a series of speech processing hardware and speech processing strategy, implemented by Cochlear Limited, and based on research findings that have resulted in an increase in mean speech perception benefits for adults and children.