    The effect of language knowledge on speech perception: what are we really assessing?
    Sarant, Julia Z. ; Blamey, Peter J. ; Cowan, Robert S. ; Clark, Graeme M. ( 1997)
    Objective: The authors examined whether open-set speech perception scores are limited by knowledge of vocabulary and syntax and further considered whether remediation of vocabulary and syntax will increase open-set speech perception scores. Study Design: This was a repeated-measures study design in the setting of a primary (elementary) school for the hearing impaired. Patients: The study population was composed of three hearing-impaired children using Nucleus 22-channel cochlear implant. Intervention: Intervention used was language remediation sessions. Main Outcome Measures: The main outcome measures were assessment of auditory-alone speech perception benefit using open-set words and sentences and assessment of syntactic knowledge using the Test of Syntactic Ability. Outcome measures were applied before and after remediation. Results: Child 1 and child 2 showed a significant postremediation improvement in their overall scores on the Test of Syntactic Ability and in their ability to perceive words learned during remediation. Child I and child 2 also showed a significant improvement in their scores on a modified Bamford-Kowal-Bench open-set sentence test, which specifically targeted grammatical constructs trained in remediation sessions. Conclusions: Remediation of language knowledge deficits significantly improved open-set speech perception for two children, suggesting a need to include language remediation in cochlear implant habilitation programs.
  • Item
    Thumbnail Image
    Speech perception in implanted children: influence of preoperative residual hearing on outcomes [Abstract]
    Cowan, R. S. C. ; Barker, E. J. ; Pegg, P. ; Dettman, S. ; Rennie, M. ; Galvin, K. ; Meskin, T. ; Rance, G. ; Cody, K. ; Sarant, J. ; Larratt, M. ; Latus, K. ; HOLLOW, RODNEY ; Rehn, C. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1998)
    Since the first child was implanted with the Nucleus 22-channel prosthesis in Melbourne in 1985, several thousand children world-wide have now benefitted from this technology. More effective paediatric assessment and management procedures have now been developed, allowing cochlear implants to be offered to children under the age of 2 years. Improvements in speech processing strategy have also been implemented in the Nucleus implant system, resulting in increased mean speech perception benefits for implanted adults. Although a range of performance on formal measures of hearing, speech or language has been reported for children using implants, results from the first decade of implant experience consistently show that significant benefits are available to children receiving their implant at an early age. Reported speech perception results for implanted children show that a considerable proportion (60%) of paediatric patients in the Melbourne and Sydney clinics are able to understand some open-set speech using electrical stimulation alone. These results, and the upward trend of mean speech perception benefits shown for postlinguistically deafened adults have raised questions as to whether severely, or severely-to-profoundly deaf children currently using hearing aids would in fact benefit more from a cochlear implant. To investigate the potential influence of the degree of preoperative residual hearing on postoperative speech perception, results for all implanted children in the Melbourne and Sydney cochlear implant programs were analysed. Results showed that as a group, children with higher levels of preoperative residual hearing were consistently more likely to achieve open-set speech perception benefits. Potential factors in this finding could be higher levels of ganglion cell survival or greater patterning of the auditory pathways using conventional hearing aids prior to implantation. Conversely, children with the least preoperative residual hearing were less predictable, with some children achieving open-set perception, and others showing more limited closed-set benefits to perception. For these children, it is likely that preoperative residual hearing is of less significance than other factors in outcomes.
  • Item
    Thumbnail Image
    Within-subject comparison of speech perception benefits for congenitally deaf adolescents with an electrotactile speech processor and a cochlear implant
    SARANT, JULIA ; COWAN, ROBERT ; BLAMEY, PETER ; GALVIN, KARYN ; Clark, Graeme M. ( 1996)
    This study assessed speech perception benefits for three congenitally deaf adolescents who used an electrotactile speech processor (Tickle Talkerâ„¢) and subsequently went on to use a Nucleus Minisystem 22 cochlear implant. Both devices provided significant and comparable benefits for all children in the device plus lipreading condition. All children benefited from the additional information provided by either the Tickle Talkerâ„¢ or the cochlear implant, and were able to perceive speech information with these devices that was not available through either aided residual hearing or lipreading. None of the three children were able to understand open-set words or sentences using either hearing aids alone or Tickle Talkerâ„¢ alone, without the aid of lipreading. Two of the children showed significant open-set speech perception benefits while using their cochlear implant alone.
  • Item
    Thumbnail Image
    Introduction: International Cochlear Implant, Speech and Hearing Symposium - Melbourne 1994
    Clark, Graeme M. ; Cowan, Robert S. C. ( 1995)
    The International Cochlear Implant Speech and Hearing Symposium - Melbourne 1994 covered a wide range of presentations in a number of disciplines. The scientific program included 287 oral presentations and 40 posters, presented to a total of 456 delegates from 38 countries. This was a considerable expansion in the number and range of presentations from the first international conference held in Melbourne in 1985 (Ann Otol Rhinal Laryngal 1987;96[suppl 128]). This growth highlights the importance of the discipline and the advances being made in this area.
  • Item
    Thumbnail Image
    The progress of children using the multichannel cochlear implant in Melbourne
    Cowan, R. S. C. ; Dowell, R. C. ; Hollow, R. ; Dettman, S. J. ; Rance, G. ; Barker, E. J. ; Sarant, J. Z. ; Galvin, K. L. ; Webb, R. C. ; Pyman, B. C. ; Cousins, V. C. ; Clark, Graeme M. ( 1995)
    Multi-channel cochlear implantation in children began in Australia in 1985 and there are now close to 4000 profoundly deaf children and adolescents using the Australian implant system around the world. The aim of the implant procedure is to provide adequate hearing for speech and language development through auditory input. This contrasts with the situation for adults with acquired deafness where the cochlear implant aims to restore hearing for someone with well-developed auditory processing and language skills. As with adults, results vary over a wide range for children using the Multi-channel implant. Many factors have been suggested that may contribute to differences in speech perception for implanted children. In an attempt to better understand these factors, the speech perception results for children implanted in Melbourne were reviewed and subjected to statistical analysis. This has indicated that the amount of experience with the implant and the length of sensory deprivation are strongly correlated with perceptual results. This means that younger children are likely to perform better with an implant and that a number of years of experience are required for children to reach their full potential. The results have also indicated that educational placement and management play a crucial role in children reaching their potential. Overall, 60% of the children and adolescents in the study have reached a level of open-set speech understanding using the cochlear implant without lipreading.
  • Item
    Thumbnail Image
    Within-subject comparison of speech perception benefits with a multiple-channel cochlear implant and tactile device
    Sarant, J. Z. ; Cowan, R. S. C. ; Blamey, P. J. ; Galvin, K. L. ; Clark, Graeme M. ( 1995)
    In order to adequately advise prospective cochlear implant patients and their families, a clinician must have a good knowledge of the potential for particular individuals to benefit from cochlear implants and other alternatives.
  • Item
    Thumbnail Image
    Speech perception in children using the advanced Speak speech-processing strategy
    Cowan, R. S. C. ; Brown, C. ; Whitford, L. A. ; Galvin, K. L. ; Sarant, J. Z. ; Barker, E. J. ; Shaw, S. ; King, A. ; Skok, M. ; Seligman, P. M. ; Dowell, R. C. ; Everingham, C. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1995)
    The Speak speech-processing strategy, developed by the University of Melbourne and commercialized by Cochlear Pty Limited for use in the new Spectra 22 speech processor, has been shown to provide improved speech perception for adults in both quiet and noisy situations. The present study evaluated the ability of children experienced in the use of the Multipeak (Mpeak) speech-processing strategy (implemented in the Nucleus Minisystem-22 cochlear implant) to adapt to and benefit from the advanced Speak speech-processing strategy (implemented in the Nucleus Spectra 22 speech processor). Twelve children were assessed using Mpeak and Speak over a period of 8 months. All of the children had over 1 year's previous experience with Mpeak, and all were able to score significantly on open-set word and sentence tests using the cochlear implant alone. Children were assessed with both live-voice and recorded speech materials, including Consonant-Nucleus-Consonant monosyllabic words and Speech Intelligibility Test sentences. Assessments were made in both quiet and in noise. Assessments were made at 3-week intervals to investigate the ability of the children to adapt to the new speech-processing strategy. For most of the children, a significant advantage was evident when using the Speak strategy as compared with Mpeak. For 4 of the children, there was no decrement in speech perception scores immediately following fitting with Speak. Eight of the children showed a small (10% to 20%) decrement in speech perception scores for between 3 and 6 weeks following the changeover to Speak. After 24 weeks' experience with Speak, 11 of the children had shown a steady increase in speech perception scores, with final Speak scores higher than for Mpeak. Only 1 child showed a significant decrement in speech perception with Speak, which did not recover to original Mpeak levels.
  • Item
    Thumbnail Image
    Preoperative residual hearing as a predictor of postoperative speech scores for adult cochlear implant users [Abstract]
    COWAN, ROBERT ; HOLLOW, RODNEY ; DOWELL, RICHARD ; PYMAN, BRIAN ; Clark, Graeme M. ( 1994)
    The development of multiple channel cochlear implants has been a significant advance in the rehabilitation of profound hearing loss. Speech perception benefits have been particularly evident for postlinguistically deafened adults, who as a group have shown not only supplementation of lipreading scores but also significant comprehension of words and sentences using an implant alone, without the aid of lipreading. In many cases, patients are able to use their implant for telephone conversation. Speech perception benefits for adult users have increased with advances in speech processing and improved means of habilitation. These improvements in open-set speech benefits for adult users have resulted in a steady increase in group mean scores and a reevaluation of selection criteria for cochlear implantation. In the initial development of cochlear implants, only those with little or no residual hearing were considered as candidates. Current selection criteria now include those with substantial residual hearing, who may score up to 40% in the best-aided condition on word and sentence speech perception tests. In order to provide realistic expectations for prospective cochlear implant patients, it is important to establish the relationship of many preimplant factors to postimplant speech perception benefits. For severely hearing impaired adults, the relationship between preoperative residual hearing, as measured by aided word and sentence speech perception test scores, and postoperative speech perception benefits is of significant interest. Analysis of data collected over a 15 year period for adult patients is presented. The rationale for conducting full speech perception assessments for all potential cochlear implant patients is stressed.
  • Item
    Thumbnail Image
    A clinical report on vocabulary skills in cochlear implant users [Abstract]
    Dawson, P. ; Blamey, P. ; Dettman, S. ; Rowland, L. ; Barker, E. ; Cowan, R. ; Clark, Graeme M. ( 1994)
    Receptive vocabulary results are reported for 32 children, adolescents and prelinguistically deafened adults implanted with the 22-electrode cochlear implant at the Melbourne Cochlear Implant Clinic. Age at implantation ranged from 2 years, 6 months to 20 years and implant use ranged from 1 year to 7 years, 8 months. There were significant gains from pre- to postoperative assessments on the Peabody Picture Vocabulary Test (PPVT) for the majority of subjects. Rates of improvement found are compatible with previous reports on smaller numbers of implant users, but cannot be attributable unambiguously to use of the implant. The group postoperative performance was significantly higher than mean preoperative performance (n =25). The relationship of variables such as duration of implant use, duration of profound deafness and speech perception ability to improvement on the PPVT is discussed. Expressive vocabulary results on the Renfrew Word Finding Vocabulary Scale are reported for 11 of the subjects. Less substantial gains were made on this measure.
  • Item
    Thumbnail Image
    A clinical report on speech production of cochlear implant users [Abstract]
    Dawson, P. ; Blamey, P. ; Dettman, S. ; Rowland, L. ; Barker, E. ; Tobey, E. ; Busby, P. ; Cowan, R. ; Clark, Graeme M. ( 1994)
    Speech production results are reported for a group of 15 children, adolescents and prelinguistically deafened adults implanted with the 22-electrode cochlear implant. Age at implantation ranged from 5 years to 20 years and implant experience ranged from 1 year to 4 years, 7 months. On a speech intelligibility test using sentences seven implant users improved significantly over time. Mean group performance (n = 11) improved from 18% preoperatively to 43% postoperatively. Similarly on a test of articulation, eight implant users improved significantly over time and the group mean postoperative performance (n = 11) exceeded the preoperative performance (55% compared to 38%). This group effect was significant for consonants and blends but was nonsignificant for vowels. Improvements occurred for front, middle and back consonants, for stops, nasals, fricatives and glides and for voiceless and voiced consonants. Three implant users showed no significant gain on either test. The results suggest complex relationships between speech production performance and sensory information provided by a multichannel implant.