Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 56
  • Item
    Thumbnail Image
    A multiple-channel cochlear implant: an evaluation using open-set CID sentences
    Clark, Graeme M. ; Tong, Yit Chow ; Martin, Lois F. A. ( 1981)
    A multiple-channel cochlear implant and speech processor have been used in two postlingually deaf adult patients with a total hearing loss, to enable them to perceive varying degrees of running speech. The results have been confirmed with open-set CID everyday sentence tests. Using the implant alone, the patients obtained 8% and 14% scores with pre-recorded material, and 34% and 36% scores for "live" presentations. This was equivalent to the perception of 35% of connected discourse. When the implant was used in conjunction with lipreading, improvements of 188% and 386% were obtained over lipreading alone, and the scores were 68% and 98% which were equivalent to the perception of 60% and 95% of connected discourse.
  • Item
    Thumbnail Image
    The surgery for multiple-electrode cochlear implantations
    Clark, Graeme M. ; Pyman, Brian C. ; Bailey, Quentin R. (Cambridge University Press, 1979)
    The multiple-electrode hearing prosthesis designed in the Departments of Otolaryngology and Electrical Engineering (UMDOLEE) at the University of Melbourne (Clark et al., 1977) has been miniaturized with hybrid circuitry so that, if design changes are necessary as a result of initial patient testing, they can be made at minimal cost. This results, however, in increased package dimensions which makes its placement and the design of the surgery more critical. This problem is increased by the fact that we have considered it important to be able to remove the package and replace it with another without disturbing the implanted electrode array, should the first receiver-stimulator fail or an improved design become available. This has meant the design of a special connector (Patrick, 1977; Clark et al., 1978) which adds to the dimensions of the implanted unit. In addition the placement of the coils for transmitting power and information has to be considered. Not only is it desirable to site the coils at a convenient location behind the ear to facilitate the placement and wearing of the external transmitter, but there should also be no relative movement between the coils and the electronic package. These design considerations have led to the sitting of the coils on top of the hermetically-sealed box, and further increased the height of the package. The dimensions of the package shown in Fig. 1 are length 42 mm, width 32 mm, height of connector 8.5 mm, height of receiver-stimulato unit 13 mm. The surgical considerations discussed are the result of a number of temporal bone and cadaver dissections, and the surgical implantation at The Royal Victorian Eye and Ear Hospital of the UMDOLEE unit in a specially-selected patient.
  • Item
    Thumbnail Image
    A cochlear implant round window electrode array
    Clark, Graeme M. ; Patrick, J. F. ; Bailey, Q. (Cambridge University Press, 1979)
    One important aspect of cochlear implantation is the placement of a multiple-electrode array close to residual auditory nerve fibres so that discrete groups of fibres can be stimulated electrically according to the place basis of frequency coding. Furthermore, in patients who are postlingually deaf these electrodes should lie in relation to the nerve fibres which are responsible for transmitting the frequencies which are important in speech comprehension, viz. 300-3,000 Hz. The method of electrode insertion should also ensure that there is no significant damage to auditory nerve fibres.
  • Item
    Thumbnail Image
    A multiple-electrode cochlear implant
    Clark, Graeme M. ; Tong, Y. C. ; Bailey, Q. R. ; Black, R. C. ; Martin, L. F. ; Millar, J. B. ; O'Loughlin B. J. ; Patrick, J. F. ; Pyman, B. C. ( 1978)
    Interest in artificially stimulating the auditory nerve electrically for sensori-neural deafness was first sparked off by Volta in the 18th century. Count Volta, who was the first to develop the electric battery, connected up a number of his batteries to two metal rods which he inserted into his ears. Having placed the rods in his ears he pressed the switch and received "une secousse dans la tete" and perceived a noise like "the boiling of thick soup".
  • Item
    Thumbnail Image
    Design criteria of a multiple-electrode cochlear implant hearing prosthesis
    Clark, Graeme M. ; Black, R. C. ; Forster, I. C. ; Patrick, J. F. ; Tong, Y. C. ( 1978)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Hearing restoration with the multichannel auditory brainstem implant
    Briggs, R. J. S. ; Kaye, A. H. ; Dowell, R. C. ; Hollow, R. D. ; Clark, Graeme M. ( 1997)
    Restoration of useful hearing is now possible in patients with bilateral acoustic neuromas by direct electrical stimulation of the cochlear nucleus. Our first experience with the Multichannel Auditory Brainstem Implant is reported. A forty four year old female with bilateral acoustic neuromas and a strong family history of Neurofibromatosis Type II presented with profound bilateral hearing impairment. Translabyrinthine removal of the right tumour was performed with placement of the Nucleus eight electrode Auditory Brainstem Implant. Intraoperative electrically evoked auditory brainstem response monitoring successfully confirmed placement over the cochlear nucleus. Postoperatively, auditory responses were obtained on stimulation of all electrodes with minimal non-auditory sensations. The patient now receives useful auditory sensations using the "SPEAK" speech processing strategy. Auditory brainstem Implantation should be considered for patients with Neurofibromatosis Type II in whom hearing preservation tumour removal is not possible.
  • Item
    Thumbnail Image
    Electrical stimulation of the auditory nerve with a cochlear implant and the temporal coding of sound frequencies: a brief review
    Clark, Graeme M. ( 1997)
    There is considerable evidence that the brain translates (encodes) the frequency of a sound into both place of excitation (place encoding), and the pattern of intervals between action potentials (temporal encoding). Furthermore, temporal encoding is now thought to be due to a temporal as well as spatial pattern of action potentials in a small group of neurons. This pattern needs to be reproduced with a cochlear implant for improved speech processing. Our recent research has also demonstrated that the timing of excitatory postsynaptic potentials seen with intracellular recordings from brain cells, rather than extracellularly recorded action potentials, correlates better with the frequency of sound. These excitatory postsynaptic potentials are likely to be the link between the patterns of action potentials arriving at nerve cells and the biomolecular activity in the cell. This response also needs to be replicated with improved speech processing strategies.
  • Item
    Thumbnail Image
    Speech results with a bilateral multi-channel cochlear implant subject for spatially separated signal and noise
    van Hoesel, Richard J. M. ; Clark, Graeme M. ( 1999)
    Speech tests in noise were administered to a bilaterally implanted cochlear implant subject. Performance for simultaneous use of two identical implants, with the same speech processing strategy on two independent standard clinical processors, was compared with that of the better performing monaural side alone. Speech was presented at an angle of 45 degrees toward one ear, with noise at 45 degrees toward the contralateral side. Tests were also administered for speech and noise reversed in location. When the speech signal was on the same side as the subject's better performing ear, monaural and binaural tests resulted in similar scores. When the speech was on the opposite side, however, the binaural condition showed significantly better speech scores. The results indicate that binaural implants can provide improved performance in noise when speech and noise arc spatially separated.
  • Item
    Thumbnail Image
    The effects of stochastic neural activity in a model predicting intensity perception with cochlear implants: low-rate stimulation
    Bruce, Ian C. ; White, Mark W. ; Irlicht, Laurence S. ; O'Leary, Stephen J. ; Clark, Graeme M. ( 1999)
    Most models of auditory nerve response to electrical stimulation are deterministic, despite significant physiological evidence for stochastic activity. Furthermore, psychophysical models and analyses of physiological data using deterministic descriptions do not accurately predict many psychophysical phenomena. In this paper we investigate whether inclusion of stochastic activity in neural models improves such predictions. To avoid the complication of interpulse interactions and to enable the use of a simpler and faster auditory nerve model we restrict our investigation to single pulses and low-rate (<200 pulses/s) pulse trains. We apply signal detection theory to produce direct predictions of behavioural threshold, dynamic range and intensity difference limen. Specifically, we investigate threshold versus pulse duration (the strength-duration characteristics), threshold and uncomfortable loudness (and the corresponding dynamic range) versus phase duration, the effects of electrode configuration on dynamic range and on strength-duration, threshold versus number of pulses (the temporal-integration characteristics), intensity difference limen as a function of loudness, and the effects of neural survival on these measures. For all psychophysical measures investigated, the inclusion of stochastic activity in the auditory nerve model was found to produce more accurate predictions.
  • Item
    Thumbnail Image
    A stochastic model of the electrically stimulated auditory nerve: pulse-train response
    Bruce, Ian C. ; Irlicht, Laurence S. ; White, Mark W. ; O'Leary, Stephen J. ; Dynes, Scott ; Javel, Eric ; Clark, Graeme M. ( 1999)
    The single-pulse model of the companion paper [1] is extended to describe responses to pulse trains by introducing a phenomenological refractory mechanism. Comparisons with physiological data from cat auditory nerve fibers are made for pulse rates between 100 and 800 pulses/s. First, it is shown that both the shape and slope of mean discharge rate curves are better predicted by the stochastic model than by the deterministic model. Second, while interpulse effects such as refractory effects do indeed increase the dynamic range at higher pulse rates, both the physiological data and the model indicate that much of the dynamic range for pulse-train stimuli is due to stochastic activity. Third, it is shown that the stochastic model is able to predict the general magnitude and behavior of variance in discharge rate as a function of pulse rate, while the deterministic model predicts no variance at all.