Graeme Clark Collection

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 16
  • Item
    Thumbnail Image
    The effects of electrode position and stimulus period on the hearing sensations in a multiple-channel cochlear implant patient [Abstract]
    Tong, Y. C. ; Blamey, P. J. ; Dowell, R. C. ; Clark, Graeme M. ( 1981)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Perceptual dissimilarity and discrimination studies using two-electrode stimulation with a multiple-channel cochlear implant patient [Abstract]
    Dowell, R. C. ; Tong, Y. C. ; Blamey, P. J. ; Clark, Graeme M. ( 1981)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Predicting speech perception results for children using multichannel cochlear implants [Abstract]
    Dowell, Richard C. ; Dettman, Shani J. ; WILLIAMS, SARAH ; Hill, Katie ; TOMOV, ALEXANDRA ; Clark, Graeme M. ( 2002)
    It is most helpful in counselling families considering cochlear implantation to have some ability to predict outcomes for individual hearing-impaired children. Speech perception results for open-set words and sentences have been collected for all children implanted with the Nucleus device in Melbourne. Assessments are available at approximately six month intervals following implantation, Data was collected for each child regarding type of hearing loss, duration and age at onset of profound hearing loss, age at implantation, pre and post-implant communication mode, developmental delay, speech coding scheme and implant experience. These data were used as predictor variables in step-wise multiple linear regression analyses with the speech perception scores as the dependent variables. Shorter duration of profound hearing loss, later onset of profound hearing loss, exclusively oral communication mode following implantation, and longer implant experience were associated with significantly (p < 0.00 I) improved open-set speech perception. The use of the SPEAK signal coding scheme was shown to provide significantly better speech perception performance for children (p < 0.00 I). Developmental delay was associated with poorer speech perception outcomes (p < 0.0 I). Over 50% of the variance in speech perception scores was accounted for by these variables. The study suggests that younger implantation for congenitally deaf children leads to improved speech perception results. On the other hand, the development of auditory language skills in implanted children may be as important as age at implantation in enhancing long term outcomes. Regression equations derived from these results can be used to predict outcomes for cochlear implant candidates with a reasonable accuracy.
  • Item
    Thumbnail Image
    Speech perception in implanted children: influence of preoperative residual hearing on outcomes [Abstract]
    Cowan, R. S. C. ; Barker, E. J. ; Pegg, P. ; Dettman, S. ; Rennie, M. ; Galvin, K. ; Meskin, T. ; Rance, G. ; Cody, K. ; Sarant, J. ; Larratt, M. ; Latus, K. ; HOLLOW, RODNEY ; Rehn, C. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1998)
    Since the first child was implanted with the Nucleus 22-channel prosthesis in Melbourne in 1985, several thousand children world-wide have now benefitted from this technology. More effective paediatric assessment and management procedures have now been developed, allowing cochlear implants to be offered to children under the age of 2 years. Improvements in speech processing strategy have also been implemented in the Nucleus implant system, resulting in increased mean speech perception benefits for implanted adults. Although a range of performance on formal measures of hearing, speech or language has been reported for children using implants, results from the first decade of implant experience consistently show that significant benefits are available to children receiving their implant at an early age. Reported speech perception results for implanted children show that a considerable proportion (60%) of paediatric patients in the Melbourne and Sydney clinics are able to understand some open-set speech using electrical stimulation alone. These results, and the upward trend of mean speech perception benefits shown for postlinguistically deafened adults have raised questions as to whether severely, or severely-to-profoundly deaf children currently using hearing aids would in fact benefit more from a cochlear implant. To investigate the potential influence of the degree of preoperative residual hearing on postoperative speech perception, results for all implanted children in the Melbourne and Sydney cochlear implant programs were analysed. Results showed that as a group, children with higher levels of preoperative residual hearing were consistently more likely to achieve open-set speech perception benefits. Potential factors in this finding could be higher levels of ganglion cell survival or greater patterning of the auditory pathways using conventional hearing aids prior to implantation. Conversely, children with the least preoperative residual hearing were less predictable, with some children achieving open-set perception, and others showing more limited closed-set benefits to perception. For these children, it is likely that preoperative residual hearing is of less significance than other factors in outcomes.
  • Item
    Thumbnail Image
    Multichannel auditory brainstem implants: an Australian case study [Abstract]
    Hollow, Rod ; COWAN, ROBERT ; BRIGGS, ROBERT ; KAYE, ANDREW ; DOWELL, RICHARD ; Shaw, Stephanie ; Clarke, Graeme M. ( 1996)
    The multichannel Auditory Brainstem Implant (ABI) is an implantable device designed to restore a level of auditory perception in patients with bilateral acoustic neuromas, where the removal of the tumours is expected to result in a total loss of hearing. As with the cochlear implant, the ABI utilises an externally worn speech processor and headset, together with a surgically-placed receiver-stimulator and electrode array. The electrode array, developed through the collaboration of the House Ear Institute in the United States and Cochlear Corporation, consists of eight electrodes on a carrier, which is placed on the surface of the brainstem in the area of the cochlear nucleus.
  • Item
    Thumbnail Image
    Current trends in speech perception performance in adult cochlear implant patients [Abstract]
    Hollow, Rod ; Plant, Kerrie ; Whitford, Lesley ; Skok, Marisa ; DOWELL, RICHARD ; Clark, Graeme M. ( 1996)
    In 1994, Cochlear Pty. Ltd. (Now Cochlear Limited) released a new speech processor, the Spectra 22, for use with the Nucleus 22-channel cochlear implant. The Spectra 22 speech processor incorporates a new speech processing strategy called SPEAK, which is based upon research conducted by the University of Melbourne. This paper reports post-operative scores on open-set word and sentence materials for adult patients in the Melbourne Cochlear Implant Clinic who have been started up with the Spectra 22 speech processor.
  • Item
    Thumbnail Image
    Speech perception in people with a severe hearing loss: preliminary results [Abstract]
    Flynn, Mark C. ; Dowell, Richard C. ; Clark, Graeme M. ( 1996)
    Recent improvements in multichannel cochlear implants have led to improved speech perception for people with profound hearing impairments. Given this improvement, it has been suggested that some people with severe hearing impairments would be more successful with a cochlear implant than a hearing aid. Unfortunately little research exists to support the suitability of cochlear implants for these individuals. In order to determine this, a detailed investigation of the aided performance of people with severe hearing losses is being conducted at The University of Melbourne (School of Audiology). Severe hearing loss was defined as a pure tone average of greater than 60dBHL, but no worse that 100dBSPL in the better ear. At present, 15 participants have taken part in this study and their results will be discussed. Each participant took part in a standard audiometric assessment which included an audiogram, AB words, tympanometry with acoustic reflexes and an ABR. Each participant’s hearing aids were assessed to make sure that they were optimally aided. Following the hearing aid evaluation the participants took part in a series of traditional speech perception tests which included 24 consonant recognition, 11 vowel recognition, CNC words, CUNY sentences, and the Connected Speech Test (CSTv2). Other tests of speech perception were conducted which looked at the effects of different types of background noise, amounts of reverberation, rates of speech and amount of available context. The aim of this was to better simulate “real-life” listening conditions. Consequently, a range of results for both traditional assessments of speech perception and simulated listening conditions will be presented and compared.
  • Item
    Thumbnail Image
    Speech perception for hearing aid users versus cochlear implantees [Abstract]
    Flynn, Mark C. ; Dowell, Richard C. ; Clark, Graeme M. ( 1996)
    Abstract not available due to copyright.
  • Item
    Thumbnail Image
    Speech perception for children with different levels of residual hearing using the cochlear 22-channel cochlear prosthesis [Abstract[
    Cowan, R. S. C. ; Galvin, K. L. ; Barker, E. J. ; Del Dot, J. ; Sarant, J. Z. ; Dettman, S. ; Hollow, R. ; Herridge, S. ; Rance, G. ; Larratt, M. ; Skok, M. ; Dowell, R. C. ; Pyman, B. ; Gibson, W. P. R. ; Clark, Graeme M. ( 1996)
    Over the past 10 years, since the implantation of the first children with the Nucleus 22-channel cochlear prosthesis in Melbourne, the number of profoundly deaf children using this implant system has rapidly expanded. Longer-term experience with implanted children has led to improvements in paediatric assessment and management. Speech processing strategies have also been improved, resulting in a series of increases in speech perception benefits. Results of comparative studies of Speak and Multipeak speech processing strategies have shown that open-set word and sentence scores for a group of thirteen children evaluated over a two year period showed an advantage with the Speak speech processing strategy. The increases were noted particularly in speech perception in poor signal-to-noise conditions. Analysis has shown that consonant perception was significantly increased, due to an improved place perception. Given current speech perception scores for implanted children, it has been suggested that severely-to-profoundly deaf children currently using hearing aids could in fact benefit more from a cochlear implant. Preliminary investigation of results for children in the Melbourne and Sydney cochlear implant programs has shown that children with higher levels of preoperative residual hearing as a group do score significantly on open-set word and sentence perception tests using the implant alone. In children with lower levels of residual hearing, results were variable across the group.
  • Item
    Thumbnail Image
    Preoperative residual hearing as a predictor of postoperative speech scores for adult cochlear implant users [Abstract]
    COWAN, ROBERT ; HOLLOW, RODNEY ; DOWELL, RICHARD ; PYMAN, BRIAN ; Clark, Graeme M. ( 1994)
    The development of multiple channel cochlear implants has been a significant advance in the rehabilitation of profound hearing loss. Speech perception benefits have been particularly evident for postlinguistically deafened adults, who as a group have shown not only supplementation of lipreading scores but also significant comprehension of words and sentences using an implant alone, without the aid of lipreading. In many cases, patients are able to use their implant for telephone conversation. Speech perception benefits for adult users have increased with advances in speech processing and improved means of habilitation. These improvements in open-set speech benefits for adult users have resulted in a steady increase in group mean scores and a reevaluation of selection criteria for cochlear implantation. In the initial development of cochlear implants, only those with little or no residual hearing were considered as candidates. Current selection criteria now include those with substantial residual hearing, who may score up to 40% in the best-aided condition on word and sentence speech perception tests. In order to provide realistic expectations for prospective cochlear implant patients, it is important to establish the relationship of many preimplant factors to postimplant speech perception benefits. For severely hearing impaired adults, the relationship between preoperative residual hearing, as measured by aided word and sentence speech perception test scores, and postoperative speech perception benefits is of significant interest. Analysis of data collected over a 15 year period for adult patients is presented. The rationale for conducting full speech perception assessments for all potential cochlear implant patients is stressed.