Medicine (Western Health) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Calcaneal ultrasound reference ranges for Australian men and women: the Geelong Osteoporosis Study
    Gould, H ; Brennan, SL ; Nicholson, GC ; Kotowicz, MA ; Henry, MJ ; Pasco, JA (SPRINGER LONDON LTD, 2013-04)
    UNLABELLED: Heel ultrasound is a more portable modality for assessing fracture risk than dual-energy X-ray absorptiometry and does not use ionising radiation. Fracture risk assessment requires appropriate reference data to enable comparisons. This study reports the first heel ultrasound reference ranges for the Australian population. INTRODUCTION: This study aimed to develop calcaneal (heel) ultrasound reference ranges for the Australian adult population using a population-based random sample. METHODS: Men and women aged≥20 years were randomly selected from the Barwon Statistical Division in 2001-2006 and 1993-1997, respectively, using the electoral roll. Broadband ultrasound attenuation (BUA), speed of sound (SOS) and stiffness index (SI) were measured at the heel using a Lunar Achilles Ultrasonometer. Gender-specific means and standard deviations for BUA, SOS and SI were calculated for the entire sample (men 20-93 years, n=1,104; women 20-92 years, n=914) and for participants aged 20-29 years (men, n=157; women, n=151). Associations between ultrasound measures and age were examined using linear regression. RESULTS: For men, mean±standard deviation BUA, SOS and SI were 118.7±15.8 dB/MHz, 1,577.0±43.7 m/s and 100.5±20.7, respectively; values for women were consistently lower (111.0±16.4 dB/MHz, P<0.001; 1,571.0±39.0 m/s, P=0.001; and 93.7±20.3, P<0.001, respectively). BUA was higher in young men compared with young women (124.5±14.4 vs 121.0±15.1 dB/MHz), but SOS (1,590.1±43.1 vs 1,592.5±35.0 m/s) and SI (108.0±19.9 vs 106.3±17.7) were not. The relationships between age and each ultrasound measure were linear and negative across the age range in men; associations were also negative in women but non-linear. CONCLUSION: These data provide reference standards to facilitate the assessment of fracture risk in an Australian population using heel ultrasound.
  • Item
    Thumbnail Image
    Total and Appendicular Lean Mass Reference Ranges for Australian Men and Women: The Geelong Osteoporosis Study
    Gould, H ; Brennan, SL ; Kotowicz, MA ; Nicholson, GC ; Pasco, JA (SPRINGER, 2014-04)
    The aim of this study was to develop reference ranges for total and appendicular lean mass measured using dual-energy X-ray absorptiometry (DXA) from a randomly selected population-based sample of men and women residing in southeastern Australia. Men (n = 1,411) and women (n = 960) aged 20-93 years, enrolled in the Geelong Osteoporosis Study, were randomly selected from the Barwon Statistical Division using the electoral roll as a sampling frame in 2001-2006 (67 % participation) and 1993-1997 (77 % participation), respectively. Using DXA (Lunar DPX-L or Prodigy Pro) at baseline for men and at the 10-year follow-up for women (2004-2008), total and appendicular lean mass were measured. Means and standard deviations for each lean mass measure (absolute and relative to height squared) were generated for each age decade, and cutpoints equivalent to T scores of -2.0 and -1.0 were calculated using data from young adult men and women aged 20-39 years. Young adult reference data were derived from 374 men and 308 women. Cutpoints for relative appendicular lean mass equal to T scores of -2.0 and -1.0 were 6.94 and 7.87 kg/m(2) for men and 5.30 and 6.07 kg/m(2) for women. The proportions of men and women aged ≥80 years with a T score less than -2.0 were 16.0 and 6.2 %, respectively. These reference ranges may be useful for identifying lean mass deficits in the assessment of muscle wasting and sarcopenia.