Optometry and Vision Sciences - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 3 of 3
  • Item
    No Preview Available
    Normative retrobulbar measurements of the optic nerve using ultra high field magnetic resonance imaging
    Nguyen, BN ; Cleary, JO ; Glarin, R ; Kolbe, SC ; Moffat, BA ; Ordidge, RJ ; Bui, BV ; McKendrick, AM (Association for Research in Vision and Ophthalmology, 2019-07-01)
    Purpose : We exploit the improved spatial resolution and signal-to-noise gain of ultra high field (7T) magnetic resonance imaging (MRI) with a dedicated eye coil for more accurate morphometric measurements of the optic nerve ~2.5mm behind the globe. Methods : Coronal T2-weighted oblique images (TR=2000ms, TE=64ms, FOV=155mm, matrix=384 x 384, slice thickness=0.7mm, scan time=2’34”) through the optic nerve were obtained in 21 healthy adults (20-41 years, 11 emmetropes: +0.75 to -0.50D, 10 myopes: -4.5 to -12D) using a 7T Siemens Magnetom scanner (Erlangen, Germany) and 6-channel eye coil (MRI.TOOLS GmbH, Berlin, Germany). Horizontal and vertical outer diameter of the optic nerve, subarachnoid space (fluid gap) and optic sheath were measured by hand using biomedical imaging software (OsiriX, Pixmeo, Switzerland) (Figure). Significant motion artefacts were avoided with customised fixation and preparation techniques. Results : Horizontal and vertical measurements were similar so were averaged. Right and left eye diameters did not differ and were highly correlated (optic nerve: Pearson r=0.9, p<0.001; fluid gap: r=0.8, p<0.001; optic sheath: r=0.7, p<0.001); hence we report left eye data only. Optic nerve diameter (average of horizontal and vertical diameters) ranged from 2.8-4.1mm in emmetropes and 1.5-4.2mm in myopes and correlated with refractive error (Spearman r=0.46, p=0.04). Similarly, fluid gap diameter (emmetropes: 3.6-5.5mm, myopes: 2.5-5.6mm), but not optic sheath diameter (emmetropes: 4.5-6.8mm, myopes: 4.2-6.8mm), correlated with refractive error (r=0.47, p=0.03). Conclusions : Ultra high field MRI with thinner slices enables more accurate demarcation of the optic nerve, surrounding fluid/subarachnoid space and optic sheath without overlapping of neighbouring anatomy (minimal partial volume artefact). Our 7T MRI-derived normative measurements of optic nerve, fluid gap and sheath diameter are comparable with published reports in healthy observers obtained at conventional MRI magnetic fields (1.5-3T). Our findings suggest a trend for retrobulbar optic nerve and subarachnoid space, but not optic sheath, to be smaller in high myopes.
  • Item
    No Preview Available
    MR-EYE: High-Resolution MRI of the Human Eye and Orbit at Ultrahigh Field (7T)
    Glarin, RK ; Nguyen, BN ; Cleary, JO ; Kolbe, SC ; Ordidge, RJ ; Bui, B ; McKendrick, AM ; Moffat, BA (Elsevier, 2021-02-01)
    Key points • Dedicated eye imaging can be implemented at 7T to acquire high-resolution, high contrast-to-noise, and high signal-to-noise images in a feasible imaging time suitable for clinical use. • Simple, reproducible participant preparation techniques can be adopted to reduce the motion of the eye leading to a reduction in subsequent artefacts. • Sequences available at ultrahigh field can be used in current 7T clinical applications to visualize ocular structures otherwise impossible with other ophthalmic imaging.
  • Item
    Thumbnail Image
    Ultra-High Field Magnetic Resonance Imaging of the Retrobulbar Optic Nerve, Subarachnoid Space, and Optic Nerve Sheath in Emmetropic and Myopic Eyes
    Nguyen, BN ; Cleary, JO ; Glarin, R ; Kolbe, SC ; Moffat, BA ; Ordidge, RJ ; Bui, BV ; McKendrick, AM (Association for Research in Vision and Ophthalmology (ARVO), 2021-02-09)
    Purpose: We aimed to image the optic nerve, subarachnoid space and optic nerve sheath in emmetropes and myopes ultra-high field (7-Tesla) magnetic resonance imaging (MRI). We targeted the retrobulbar distance of approximately 3 mm behind the eyeball, an area of clinical interest because of optic nerve sheath distensibility and pressure-related enlargement. Methods: Eleven emmetropes (+0.75 to −0.50D, aged 20–41 years) and 10 myopes (−4.5 to −12D, aged 21–37 years) participated. Cross-sectional area of the optic nerve, subarachnoid space and optic nerve sheath at approximately 3 mm behind the eye were measured from two-dimensional T2-weighted coronal oblique MRI images obtained through the left optic nerve. Axial length of the left eye was measured from T2-weighted axial MRI images. In nine emmetropes and seven myopes, the optic nerve head was imaged with optical coherence tomography to compare retrobulbar and intraocular measures. Results: Retrobulbar optic nerve, subarachnoid space and optic nerve sheath dimensions differed between myopes and emmetropes. Myopes tended to have smaller optic nerve and subarachnoid space. Longer MRI-derived axial length was associated with smaller optic nerve area (P = 0.03). Bruch's membrane opening area did not predict retrobulbar optic nerve area (P = 0.48). Conclusions: This study demonstrates the feasibility of using 7-Tesla MRI to measure optic nerve, subarachnoid space, and optic nerve sheath dimensions behind the eye. In healthy adults, the retrobulbar optic nerve and subarachnoid space size are influenced by the degree of myopia. Translational Relevance: ultra-high field MRI is a practical tool for assessing the morphometry of the optic nerve and surrounding anatomy behind the eye.