  • Item
    Thumbnail Image
    Implantation and Recording of Wireless Electroretinogram and Visual Evoked Potential in Conscious Rats
    Charng, J ; He, Z ; Bui, B ; Vingrys, A ; Ivarsson, M ; Fish, R ; Gurrell, R ; Nguyen, C (JOURNAL OF VISUALIZED EXPERIMENTS, 2016-06-01)
    The full-field electroretinogram (ERG) and visual evoked potential (VEP) are useful tools to assess retinal and visual pathway integrity in both laboratory and clinical settings. Currently, preclinical ERG and VEP measurements are performed with anesthesia to ensure stable electrode placements. However, the very presence of anesthesia has been shown to contaminate normal physiological responses. To overcome these anesthesia confounds, we develop a novel platform to assay ERG and VEP in conscious rats. Electrodes are surgically implanted sub-conjunctivally on the eye to assay the ERG and epidurally over the visual cortex to measure the VEP. A range of amplitude and sensitivity/timing parameters are assayed for both the ERG and VEP at increasing luminous energies. The ERG and VEP signals are shown to be stable and repeatable for at least 4 weeks post surgical implantation. This ability to record ERG and VEP signals without anesthesia confounds in the preclinical setting should provide superior translation to clinical data.
  • Item
    Thumbnail Image
    Reversal of functional loss in a rat model of chronic intraocular pressure elevation
    Liu, H-H ; He, Z ; Nguyen, CTO ; Vingrys, AJ ; Bui, BV (WILEY, 2017-01)
    PURPOSE: This pilot study considered whether intraocular pressure (IOP) lowering could reverse ganglion cell dysfunction in a rat model of chronic ocular hypertension. METHODS: A circumlimbal suture was applied in one eye to induce ocular hypertension (n = 7) in Long-Evans rats. The contralateral eye served as an untreated control. After 8 weeks of IOP elevation the suture was removed to lower IOP for the remaining 7 weeks. Electroretinogram (ERG) and optical coherence tomography (OCT) were measured at baseline, 2, 4, 8, 12 and 15 weeks. Retinae were collected for histology at week 15. RESULTS: In sutured eyes, IOP was elevated by 7-11 mmHg above control eyes (12 ± 0.2 mmHg [standard error of the mean]). Eight weeks of chronic IOP elevation resulted in a reduction of the ganglion cell mediated positive Scotopic Threshold Response (pSTR, -25 ± 7% of baseline), as well as smaller photoreceptor (-7 ± 4%) and bipolar cell mediated responses (-6 ± 5%). After suture removal, IOP recovered to normal. By 15 weeks the a-wave (0 ± 6%), b-wave (-2 ± 6%) and pSTR had recovered back to baseline (from -25 ± 7% to -4 ± 6%). The retinal nerve fiber layer was thinned by -9 ± 3% at week 8 and showed no further decline at week 15 (-10 ± 2%). Cell numbers in the ganglion cell layer were similar between suture removal and control eyes at week 15 (3543 ± 478 vs 4057 ± 476 cells mm-2 ). CONCLUSIONS: The circumlimbal suture model might be a useful platform to study the reversibility of neuronal dysfunction from chronic IOP challenge.
  • Item
    Thumbnail Image
    Comparing self-reported optometric dry eye clinical practices in Australia and the United Kingdom: is there scope for practice improvement?
    Downie, LE ; Rumney, N ; Gad, A ; Keller, PR ; Purslow, C ; Vingrys, AJ (WILEY-BLACKWELL, 2016-03)
    PURPOSE: The aim of this study was to compare the self-reported clinical practice behaviours of optometrists in Australia and the United Kingdom (UK) with respect to the diagnosis and management of dry eye disease (DED). We also sought to examine whether the reported practices of clinicians in each region were consistent with current evidence-based recommendations for DED. METHODS: An online survey was distributed to optometrists (Australia, n = 654; UK, n = 1006). Respondents provided information about practice modality, years of optometric experience, preferred diagnostic and management strategies (stratified by DED severity) and the information/evidence base used to guide patient care. RESULTS: A total of 317 completed surveys were received (response rates, Australia: 21%, UK: 17%). Optometrists in both regions demonstrated similarly strong knowledge of tear film assessment and adopted both subjective and objective techniques to diagnose DED. Patient symptoms were considered the most important, valuable and commonly performed assessment by both Australian and UK respondents. UK practitioners valued and utilised conjunctival signs and tear meniscus height assessments more than Australian optometrists (p < 0.05), who placed relatively greater emphasis on sodium fluorescein tear break-up time to diagnose DED (p < 0.05). Clinicians in both locations tailored DED therapy to severity. While practitioners in both regions predominantly managed mild DED with eyelid hygiene and tear supplementation, Australian optometrists indicated prescribing topical corticosteroid therapy significantly more often than UK practitioners for moderate (14% vs 6%) and severe (52% vs 8%) disease (p < 0.05). The major source of information used to guide practitioners' dry eye management practices was continuing education conferences. CONCLUSIONS: This study highlights a range of parallels and divergences in dry eye clinical practice between Australian and UK optometrists. Our data identify both areas of strength in the adoption of evidence-based practice, as well as some potential to improve international translation of dry eye research evidence into practice.
  • Item
    Thumbnail Image
    Tablets at the bedside - iPad-based visual field test used in the diagnosis of Intrasellar Haemangiopericytoma: a case report
    Nesaratnam, N ; Thomas, PBM ; Kirollos, R ; Vingrys, AJ ; Kong, GYX ; Martin, KR (BIOMED CENTRAL LTD, 2017-04-24)
    BACKGROUND: In the assessment of a pituitary mass, objective visual field testing represents a valuable means of evaluating mass effect, and thus in deciding whether surgical management is warranted. CASE PRESENTATION: In this vignette, we describe a 73 year-old lady who presented with a three-week history of frontal headache, and 'blurriness' in the left side of her vision, due to a WHO grade III anaplastic haemangiopericytoma compressing the optic chiasm. We report how timely investigations, including an iPad-based visual field test (Melbourne Rapid Field, (MRF)) conducted at the bedside aided swift and appropriate management of the patient. CONCLUSIONS: We envisage such a test having a role in assessing bed-bound patients in hospital where access to formal visual field testing is difficult, or indeed in rapid testing of visual fields at the bedside to screen for post-operative complications, such as haematoma.
  • Item
    Thumbnail Image
    Conscious Wireless Electroretinogram and Visual Evoked Potentials in Rats
    Charng, J ; Nguyen, CT ; He, Z ; Dang, TM ; Vingrys, AJ ; Fish, RL ; Gurrell, R ; Brain, P ; Bui, BV ; Frishman, L (PUBLIC LIBRARY SCIENCE, 2013-09-12)
    The electroretinogram (ERG, retina) and visual evoked potential (VEP, brain) are widely used in vivo tools assaying the integrity of the visual pathway. Current recordings in preclinical models are conducted under anesthesia, which alters neural physiology and contaminates responses. We describe a conscious wireless ERG and VEP recording platform in rats. Using a novel surgical technique to chronically implant electrodes subconjunctivally on the eye and epidurally over the visual cortex, we are able to record stable and repeatable conscious ERG and VEP signals over at least 1 month. We show that the use of anaesthetics, necessary for conventional ERG and VEP measurements, alters electrophysiology recordings. Conscious visual electrophysiology improves the viability of longitudinal studies by eliminating complications associated with repeated anaesthesia. It will also enable uncontaminated assessment of drug effects, allowing the eye to be used as an effective biomarker of the central nervous system.
  • Item
    Thumbnail Image
    Optical Coherence Tomography Reveals Changes to Corneal Reflectivity and Thickness in Individuals with Tear Hyperosmolarity
    Deinema, LA ; Vingrys, AJ ; Chinnery, HR ; Downie, LE (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2017-05)
    PURPOSE: To investigate whether tear hyperosmolarity, a feature of dry eye disease (DED), affects central corneal thickness (CCT), corneal light reflectivity, and/or tear film reflectivity. METHODS: This prospective, cross-sectional study involved 48 participants (38 with hyperosmolar tears and 10 controls with normo-osmolar tears). Symptoms and signs of DED (tear osmolarity, sodium fluorescein tear break-up time, ocular surface staining, Schirmer test) were assessed. CCT, and the reflectivity of the cornea and the tear-epithelial interface were quantified relative to background noise using Fourier-domain optical coherence tomography (FD-OCT). RESULTS: CCT of eyes with severe tear hyperosmolarity, defined as eyes in the upper quartile of the hyperosmolar group, was less than control eyes (539.1 ± 7.4 vs. 583.1 ± 15.0 μm, P = 0.02) and eyes with less severe tear hyperosmolarity, defined as hyperosmolar eyes in the lower quartile (622.7 ± 5.8 μm, P < 0.0001). CCT showed a negative linear relationship with tear osmolarity for values above 316 mOsmol/L (R2 = 0.17, P = 0.01). Central corneal reflectivity was lower in hyperosmolar eyes than normo-osmolar eyes (45.1 ± 0.3 vs. 48.1 ± 0.6 pixels, P = 0.02); the greatest relative difference was in the anterior stroma, where corneal reflectivity was 4.7 ± 1.9% less in hyperosmolar eyes (P < 0.01). Peak reflectivity of the tear-epithelial interface was 4.8% ± 3.5% higher in the hyperosmolar group than the normo-osmolar tear group (P = 0.04). CONCLUSION: Individuals with significant tear hyperosmolarity and clinical signs of symptoms of DED show reduced CCT and altered corneal reflectivity. TRANSLATIONAL RELEVANCE: Anterior segment FD-OCT provides novel insight into corneal microstructural differences in individuals with DED.
  • Item
    Thumbnail Image
    Characterization of the Circumlimbal Suture Model of Chronic IOP Elevation in Mice and Assessment of Changes in Gene Expression of Stretch Sensitive Channels.
    Zhao, D ; Nguyen, CTO ; Wong, VHY ; Lim, JKH ; He, Z ; Jobling, AI ; Fletcher, EL ; Chinnery, HR ; Vingrys, AJ ; Bui, BV (Frontiers Media SA, 2017)
    To consider whether a circumlimbal suture can be used to chronically elevate intraocular pressure (IOP) in mice and to assess its effect on retinal structure, function and gene expression of stretch sensitive channels. Anesthetized adult C57BL6/J mice had a circumlimbal suture (10/0) applied around the equator of one eye. In treated eyes (n = 23) the suture was left in place for 12 weeks whilst in sham control eyes the suture was removed at day two (n = 17). Contralateral eyes served as untreated controls. IOP was measured after surgery and once a week thereafter. After 12 weeks, electroretinography (ERG) was performed to assess photoreceptor, bipolar cell and retinal ganglion cell (RGC) function. Retinal structure was evaluated using optical coherence tomography. Retinae were processed for counts of ganglion cell density or for quantitative RT-PCR to quantify purinergic (P2x7, Adora3, Entpd1) or stretch sensitive channel (Panx1, Trpv4) gene expression. Immediately after suture application, IOP spiked to 33 ± 3 mmHg. After 1 day, IOP had recovered to 27 ± 3 mmHg. Between weeks 2 and 12, IOP remained elevated above baseline (control 14 ± 1 mmHg, ocular hypertensive 19 ± 1 mmHg). Suture removal at day 2 (Sham) restored IOP to baseline levels, where it remained through to week 12. ERG analysis showed that 12 weeks of IOP elevation reduced photoreceptor (-15 ± 4%), bipolar cell (-15 ± 4%) and ganglion cell responses (-19 ± 6%) compared to sham controls and respective contralateral eyes (untreated). The retinal nerve fiber layer was thinned in the presence of normal total retinal thickness. Ganglion cell density was reduced across all quadrants (superior -12 ± 5%; temporal, -7% ± 2%; inferior -9 ± 4%; nasal -8 ± 5%). Quantitative RT-PCR revealed a significant increase in Entpd1 gene expression (+11 ± 4%), whilst other genes were not significantly altered (P2x7, Adora3, Trpv4, Panx1). Our results show that circumlimbal ligation produces mild chronic ocular hypertension and retinal dysfunction in mice. Consistent with a sustained change to purinergic signaling we found an up-regulation of Entpd1.
  • Item
    Thumbnail Image
    Retinal and Cortical Blood Flow Dynamics Following Systemic Blood-Neural Barrier Disruption
    Hui, F ; Nguyen, CTO ; He, Z ; Vingrys, AJ ; Gurrell, R ; Fish, RL ; Bui, BV (FRONTIERS MEDIA SA, 2017-10-12)
    To consider whether imaging retinal vasculature may be used as a marker for cortical vessels, we compared fluorescein angiography flow dynamics before and after pharmacological disruption of blood-neural barriers. Sodium fluorescein (1%, 200 μl/kg) was intravenously delivered in anesthetized adult Long Evans rats (n = 44, brain = 18, retina = 26). In the brain cohort, a cranial window was created to allow direct visualization of surface cortical vessels. Video fluorescein angiography was captured using a rodent retinal camera at 30 frames/second and fluorescence intensity profiles were evaluated for the time to reach 50% brightness (half-rise), 50% decay (half-fall), and the plateau level of remnant fluorescence (offset, %). Cortical vessels fluoresced earlier (artery half-rise: 5.6 ± 0.2 s) and decayed faster (half-fall: 10.3 ± 0.2 s) compared to retinal vasculature. Cortical vessels also had a considerably higher offset, particularly in the capillaries/extravascular space (41.4 ± 2.7%) whereas pigment in the retina reduces such residual fluorescence. In a sub-cohort of animals, sodium deoxycholate (DOC, 0.06 M dissolved in sterile saline, 1 mL) was delivered intravenously to cause simultaneous disruption of the blood-brain and blood-retinal barriers. A separate group received saline as vehicle control. Fluorescein angiography was re-measured at 6 and 24 h after drug infusion and evaluated by comparing flow dynamics to the upper quartile (75%) of the control group. Retinal vasculature was more sensitive to DOC-induced disruption with a higher fluorescence offset at 6 h (47.3 ± 10.6%). A delayed effect was seen in cortical vessels with a higher offset evident only at 24 h (65.6 ± 10.1%). Here we have developed a method to quantitatively compare fluorescein angiography dynamics in the retina and superficial cortical vessels. Our results show that systemic disruption of blood-neural barriers causes vascular leakage in both tissues but earlier in the retina suggesting that pharmacological blood-neural barrier disruption may be detected earlier in the eye than in cortical vasculature.
  • Item
    Thumbnail Image
    A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients
    Kong, YXG ; He, M ; Crowston, JG ; Vingrys, AJ (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2016-11)
    PURPOSE: To determine the correlation between the perimetric outcomes from perimetry software Melbourne Rapid Fields (MRF) run on an Apple iPad tablet and those from the Humphrey Field Analyzer (HFA). METHODS: The MRF software was designed with features including variable fixation and fast thresholding using Bayes logic. Here, we report a cross-sectional study on 90 eyes from 90 participants: 12 had normal optic nerves and 78 had glaucoma with various degrees of visual field loss (41 mild and 37 moderate-severe). Exclusion criteria were patients with worse than 20/40 vision or recent intraocular surgery. The visual field outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Participants were tested twice on the MRF to establish test-retest repeatability. RESULTS: The test durations were shorter on MRF than HFA (5.7 ± 0.1 vs. 6.3 ± 0.1 minutes, P < 0.001). MRF showed a high level of concordance in its outcomes with HFA (intraclass coefficient [ICC] = 0.93 for mean defect [MD] and 0.86 for pattern deviation [PD]) although the MRF tended to give a less negative MD (1.4 dB bias) compared with the HFA. MRF also showed levels of test-retest reliability comparable to HFA (ICC = 0.93 for MD and 0.89 for PD, 95% limits of agreement -4.5 to 4.3 dB). CONCLUSION: The perimetry results from the MRF have a strong correlation to the HFA outcomes. MRF also has test-retest reliability comparable to HFA. TRANSLATIONAL RELEVANCE: Portable tablet perimetry may allow accurate assessment of visual field when standard perimetry machines are unavailable or unsuitable.
  • Item
    Thumbnail Image
    Validation of a Tablet as a Tangent Perimeter
    Vingrys, AJ ; Healey, JK ; Liew, S ; Saharinen, V ; Tran, M ; Wu, W ; Kong, GYX (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2016-07)
    PURPOSE: To describe a tangent perimeter developed on an Apple iPad (Melbourne Rapid Field, MRF). METHODS: The MRF assays 66 locations over 28° × 18° by having the patient vary fixation. Spot size and background luminance are paired to yield constant thresholds across the field. Spot locations were selected after analysis of 360 patient records. The capacity of the MRF to detect defects was verified in five participants (age 22-28 years) by simulating four common losses: central, arcuate, quadrant, and hemianopia. We also consider the effect of: myosis, blur (+3 DS), viewing distance (25-75 cm), ambient light (4-600 lux), and retest repeatability (1-week apart) on thresholds. Group means [SEM] are compared by Student's t-test and repeatability returned from Bland-Altman analysis. RESULTS: We found a 5 cd.m-2 background replicates the Weber fraction produced by a Humphrey spot shown at 35 dB. Our variable size gives constant thresholds (29.6 [0.2] dB) across all locations. Altering viewing distance (25 cm = 29.8 [0.9] dB; 75 cm = 28.9 [0.6] dB) and ambient lighting (4 lux, 29.8 [0.8] dB; 600 lux, 29.5 [1.0] dB) did not affect threshold although screen reflections must be avoided. Myosis (-1.2 dB) and blur (-1.5 dB) will reduce sensitivity (P < 0.05). Simulated defects with a mean defect (MD) of -3.3 dB are detected by the MRF. The Coefficient of repeatability was 9.6% (SD ∼2.9 dB) in normal regions and 48.1% (SD ∼8.0 dB) in areas of simulated scotoma. CONCLUSIONS: Tablet technology can return efficient and reliable thresholds to 30° as a tangent perimeter. TRANSLATIONAL RELEVANCE: The MRF will allow testing at a bedside, at home, in rural or remote areas, or where equipment cannot be financed.