Optometry and Vision Sciences - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 9 of 9
  • Item
    Thumbnail Image
    Relationship between reticular pseudodrusen and choroidal thickness in intermediate age-related macular degeneration: response
    Ho, CYD ; Lek, JJ ; Aung, KZ ; McGuinness, MB ; Luu, CD ; Guymer, RH (WILEY, 2018-11)
  • Item
    Thumbnail Image
    Relationship between reticular pseudodrusen and choroidal thickness in intermediate age-related macular degeneration
    Ho, CYD ; Lek, JJ ; Aung, KZ ; McGuinness, MB ; Luu, CD ; Guymer, RH (WILEY, 2018-07)
    IMPORTANCE: Reticular pseudodrusen (RPD) is strongly associated with late age-related macular degeneration (AMD) but their aetiology remains unknown. RPD have been associated with reduced choroidal thickness (ChT) but most studies are limited by small sample size and varying severity of AMD. BACKGROUND: To investigate the relationship between choroidal thickness and RPD in eyes with intermediate AMD (iAMD), controlling for variables known to influence ChT. DESIGN: Retrospective cohort study. PARTICIPANTS: Participants were recruited from Centre for Eye Research Australia. METHODS: Colour fundus photographs, fundus auto fluorescence, near-infrared and spectral-domain ocular coherence tomography (OCT) were graded for RPD. ChT was measured from enhanced-depth imaging OCT scans at the centre of fovea, 1500 and 3000 μm nasal, temporal, superior and inferior from centre of fovea. MAIN OUTCOME MEASURES: ChT between RPD and non-RPD group. RESULTS: A total of 297 eyes from 152 subjects were included. A total of 84 (28%) had RPD and were older than non-RPD group (75.1 ± 5.4 years and 68.7 ± 6.9 years, respectively; P < 0.001). In unadjusted analysis, the RPD group was significantly associated with thinner choroids across all measured locations (P ≤ 0.022). After adjustment for variables, the presence of RPD was no longer associated with ChT (P ≥ 0.132 for all locations) but age (P < 0.001) and refractive error (P = 0.002) remained significantly associated with ChT. CONCLUSIONS AND RELEVANCE: Age and refractive error, rather than RPD, was significantly associated with reduced ChT in eyes with iAMD. Choroidal insufficiency may be a less important variable in RPD aetiology than previously considered.
  • Item
    Thumbnail Image
    Advances in implantable bionic devices for blindness: a review
    Lewis, PM ; Ayton, LN ; Guymer, RH ; Lowery, AJ ; Blamey, PJ ; Allen, PJ ; Luu, CD ; Rosenfeld, JV (WILEY, 2016-09)
    Since the 1950s, vision researchers have been working towards the ambitious goal of restoring a functional level of vision to the blind via electrical stimulation of the visual pathways. Groups based in Australia, USA, Germany, France and Japan report progress in the translation of retinal visual prosthetics from the experimental to clinical domains, with two retinal visual prostheses having recently received regulatory approval for clinical use. Regulatory approval for cortical visual prostheses is yet to be obtained; however, several groups report plans to conduct clinical trials in the near future, building upon the seminal clinical studies of Brindley and Dobelle. In this review, we discuss the general principles of visual prostheses employing electrical stimulation of the visual pathways, focusing on the retina and visual cortex as the two most extensively studied stimulation sites. We also discuss the surgical and functional outcomes reported to date for retinal and cortical prostheses, concluding with a brief discussion of novel developments in this field and an outlook for the future.
  • Item
    Thumbnail Image
    Home Monitoring of Retinal Sensitivity on a Tablet Device in Intermediate Age-Related Macular Degeneration
    Adams, M ; Ho, CYD ; Baglin, E ; Sharangan, P ; Wu, Z ; Lawson, DJ ; Luu, CD ; Turpin, A ; McKendrick, AM ; Guymer, RH (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2018-09)
    PURPOSE: We determine the feasibility of using a home-based tablet device to monitor retinal sensitivity (RS) in intermediate age-related macular degeneration (iAMD), the benefits of weekly reminders, and the comparison with clinic-based results. METHODS: A customized test for tablets was designed to measure RS (within central 2°) in individuals with iAMD at weekly intervals in their home, with remote data collection. Half of the participants were randomized to receive weekly test reminders. Clinic-based microperimetric macular sensitivity results were compared to tablet results. Participation rates were analyzed at 2 months. RESULTS: Of 38 participants (mean age, 70.3 years) with iAMD enrolled in the study, 21 (55%) were using the tablet-based test at 2 months. Common reasons for inactivity were noncompatible devices (41.1%) or other technology access issues (35.3%). Participants with weekly reminders completed tests more regularly (6.6 ± 3.9 vs. 8.7 ± 4.1 days, P = 0.01), but weekly reminders showed no effect on participation rates (P = 0.69). Mean RS from the tablet device (25.03 ± 2.41 dB) was not significantly different from the clinic-based microperimetry performance (25.21 ± 2.20 dB; P = 0.58). CONCLUSIONS: Regular monitoring of retinal function on a tablet device in a home setting in individuals with iAMD is feasible with results comparable to those of clinic-based microperimetry. Weekly reminders resulted in more frequent testing. Seamless ability to access technology will be important for higher participation rates. TRANSLATIONAL RELEVANCE: The use of home-monitoring on a tablet-device is promising, but adequate support for an older cohort to take up technology is required if such a tool is to be useful for long-term home monitoring.
  • Item
    Thumbnail Image
    Progress in the clinical development and utilization of vision prostheses: an update
    Brandli, A ; Luu, CD ; Guymer, RH ; Ayton, LN (DOVE MEDICAL PRESS LTD, 2016)
    Vision prostheses, or "bionic eyes", are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field.
  • Item
    Thumbnail Image
    A Tablet-Based Retinal Function Test in Neovascular Age-Related Macular Degeneration Eyes and At-Risk Fellow Eye
    Ho, CYD ; Wu, Z ; Turpin, A ; Lawson, DJ ; Luu, CD ; McKendrick, AM ; Guymer, RH (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2018-03)
    PURPOSE: To determine the feasibility of a tablet-based application to detect changes in retinal sensitivity and correlations with underlying pathology in neovascular age-related macular degeneration (nAMD) eyes undergoing treatment and in at-risk fellow eyes. METHOD: Participants with nAMD in at least one eye were recruited, examined, and imaged using spectral-domain optical coherence tomography (SD-OCT). Retinal sensitivity was measured within the central 5° at 12 locations using a customized test delivered on an iPad. Test points were superimposed on SD-OCT locations to investigate structure/function relationships. RESULTS: Included in the study were 53 nAMD eyes and 21 at-risk fellow eyes. In nAMD eyes, the mean retinal sensitivity was 24.1 ± 1.8 dB with reduced retinal sensitivity associated with the presence of atrophy (P < 0.01), retinal pigment epithelium (RPE) disruption (P < 0.01), and absent ellipsoid zone (EZ) (P < 0.01), but not with the presence of subretinal fluid (P = 0.94) nor intraretinal fluid (P = 0.52). In at-risk eyes, the average retinal sensitivity was 28.8 ± 0.6 dB, with reduced sensitivity significantly associated with the presence of drusen, atrophy, RPE disruption, and absent EZ (P < 0.01). CONCLUSION: The tablet-based test of retinal sensitivity was able to be performed by an elderly cohort with nAMD. The ability to correlate differences in sensitivity with pathology is encouraging when considering using the tablet devices as a home monitoring tool with remote surveillance. Dual pathology often present with retinal fluid confounded our ability to correlate fluid with sensitivity. TRANSLATIONAL RELEVANCE: These findings highlight the potential of tablet-based devices in performing visual function measures as a home monitoring tool with remote surveillance for the earlier detection of nAMD.
  • Item
    Thumbnail Image
    Imaging Lenticular Autofluorescence in Older Subjects
    Charng, J ; Tan, R ; Luu, CD ; Sadigh, S ; Stambolian, D ; Guymer, RH ; Jacobson, SG ; Cideciyan, AV (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2017-10)
    PURPOSE: To evaluate whether a practical method of imaging lenticular autofluorescence (AF) can provide an individualized measure correlated with age-related lens yellowing in older subjects undergoing tests involving shorter wavelength lights. METHODS: Lenticular AF was imaged with 488-nm excitation using a confocal scanning laser ophthalmoscope (cSLO) routinely used for retinal AF imaging. There were 75 older subjects (ages 47-87) at two sites; a small cohort of younger subjects served as controls. At one site, the cSLO was equipped with an internal reference to allow quantitative AF measurements; at the other site, reduced-illuminance AF imaging (RAFI) was used. In a subset of subjects, lens density index was independently estimated from dark-adapted spectral sensitivities performed psychophysically. RESULTS: Lenticular AF intensity was significantly higher in the older eyes than the younger cohort when measured with the internal reference (59.2 ± 15.4 vs. 134.4 ± 31.7 gray levels; P < 0.05) as well as when recorded with RAFI without the internal reference (10.9 ± 1.5 vs. 26.1 ± 5.7 gray levels; P < 0.05). Lenticular AF was positively correlated with age; however, there could also be large differences between individuals of similar age. Lenticular AF intensity correlated well with lens density indices estimated from psychophysical measures. CONCLUSIONS: Lenticular AF measured with a retinal cSLO can provide a practical and individualized measure of lens yellowing, and may be a good candidate to distinguish between preretinal and retinal deficits involving short-wavelength lights in older eyes.
  • Item
    Thumbnail Image
    Development of a surgical procedure for implantation of a prototype suprachoroidal retinal prosthesis
    Saunders, AL ; Williams, CE ; Heriot, W ; Briggs, R ; Yeoh, J ; Nayagam, DAX ; McCombe, M ; Villalobos, J ; Burns, O ; Luu, CD ; Ayton, LN ; McPhedran, M ; Opie, NL ; McGowan, C ; Shepherd, RK ; Guymer, R ; Allen, PJ (WILEY, 2014)
    BACKGROUND: Current surgical techniques for retinal prosthetic implantation require long and complicated surgery, which can increase the risk of complications and adverse outcomes. METHOD: The suprachoroidal position is known to be an easier location to access surgically, and so this study aimed to develop a surgical procedure for implanting a prototype suprachoroidal retinal prosthesis. The array implantation procedure was developed in 14 enucleated eyes. A full-thickness scleral incision was made parallel to the intermuscular septum and superotemporal to the lateral rectus muscle. A pocket was created in the suprachoroidal space, and the moulded electrode array was inserted. The scleral incision was closed and scleral anchor point sutured. In 9 of the 14 eyes examined, the device insertion was obstructed by the posterior ciliary neurovascular bundle. Subsequently, the position of this neurovascular bundle in 10 eyes was characterized. Implantation and lead routing procedure was then developed in six human cadavers. The array was tunnelled forward from behind the pinna to the orbit. Next, a lateral canthotomy was made. Lead fixation was established by creating an orbitotomy drilled in the frontal process of the zygomatic bone. The lateral rectus muscle was detached, and implantation was carried out. Finally, pinna to lateral canthus measurements were taken on 61 patients in order to determine optimal lead length. RESULTS: These results identified potential anatomical obstructions and informed the anatomical fitting of the suprachoroidal retinal prosthesis. CONCLUSION: As a result of this work, a straightforward surgical approach for accurate anatomical suprachoroidal array and lead placement was developed for clinical application.
  • Item
    Thumbnail Image
    First-in-Human Trial of a Novel Suprachoroidal Retinal Prosthesis
    Ayton, LN ; Blamey, PJ ; Guymer, RH ; Luu, CD ; Nayagam, DAX ; Sinclair, NC ; Shivdasani, MN ; Yeoh, J ; McCombe, MF ; Briggs, RJ ; Opie, NL ; Villalobos, J ; Dimitrov, PN ; Varsamidis, M ; Petoe, MA ; McCarthy, CD ; Walker, JG ; Barnes, N ; Burkitt, AN ; Williams, CE ; Shepherd, RK ; Allen, PJ ; Mori, K (PUBLIC LIBRARY SCIENCE, 2014-12-18)
    UNLABELLED: Retinal visual prostheses ("bionic eyes") have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. TRIAL REGISTRATION: Clinicaltrials.gov NCT01603576.