Optometry and Vision Sciences - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Scaling the size of perimetric stimuli reduces variability and returns constant thresholds across the visual field
    Bedggood, P ; Prea, SM ; Kong, YXG ; Vingrys, AJ (ASSOC RESEARCH VISION OPHTHALMOLOGY INC, 2020-10)
    The conventional stimulus for standard automated perimetry is fixed in size, giving elevated contrast thresholds and reduced test reliability in the periphery. Here, we test the hypothesis that appropriate scaling of the size of perimetric stimuli will return fixed thresholds and reduced variability across the visual field. We derived frequency-of-seeing (FOS) curves in five healthy subjects at central (3 degrees) and peripheral (27 degrees) locations with a method of constant stimuli (MOCS) using a desktop LCD display. FOS curves for a Goldmann III (GIII) stimulus were compared with those for size scaled spots. To consider clinical translation, we tested a further five healthy subjects (22-24 years) with the Melbourne Rapid Fields (MRF) tablet perimeter at several locations spanning 1 degree to 25 degrees from fixation, deriving FOS curves (MOCS) and also conducting repeated adaptive clinical thresholding to assess intra- and interobserver variability. We found that GIII contrast thresholds were significantly elevated in the periphery compared with the parafovea, with concomitant reduction of FOS slope. Using appropriately size scaled spots, threshold and slope differences between these locations were significantly reduced. FOS data collected with the tablet perimeter confirmed that size scaling confers broad equivalence of the shape of the FOS curve across the visual field. Repeated adaptive thresholding with size scaled stimuli gave relatively constant intra-observer variability across the visual field, which compares favorably with published normative data obtained with the GIII stimulus. The reduced variability will improve signal-to-noise ratio for correct classification of normal visual field test results, whereas the lower contrast thresholds yield greater dynamic range, which should improve the ability to reliably monitor moderate defects.
  • Item
    Thumbnail Image
    Quantitative Spatial and Temporal Analysis of Fluorescein Angiography Dynamics in the Eye
    Hui, F ; Nguyen, CTO ; Bedggood, PA ; He, Z ; Fish, RL ; Gurrell, R ; Vingrys, AJ ; Bui, BV ; Lewin, AS (PUBLIC LIBRARY SCIENCE, 2014-11-03)
    PURPOSE: We describe a novel approach to analyze fluorescein angiography to investigate fluorescein flow dynamics in the rat posterior retina as well as identify abnormal areas following laser photocoagulation. METHODS: Experiments were undertaken in adult Long Evans rats. Using a rodent retinal camera, videos were acquired at 30 frames per second for 30 seconds following intravenous introduction of sodium fluorescein in a group of control animals (n = 14). Videos were image registered and analyzed using principle components analysis across all pixels in the field. This returns fluorescence intensity profiles from which, the half-rise (time to 50% brightness), half-fall (time for 50% decay) back to an offset (plateau level of fluorescence). We applied this analysis to video fluorescein angiography data collected 30 minutes following laser photocoagulation in a separate group of rats (n = 7). RESULTS: Pixel-by-pixel analysis of video angiography clearly delineates differences in the temporal profiles of arteries, veins and capillaries in the posterior retina. We find no difference in half-rise, half-fall or offset amongst the four quadrants (inferior, nasal, superior, temporal). We also found little difference with eccentricity. By expressing the parameters at each pixel as a function of the number of standard deviation from the average of the entire field, we could clearly identify the spatial extent of the laser injury. CONCLUSIONS: This simple registration and analysis provides a way to monitor the size of vascular injury, to highlight areas of subtle vascular leakage and to quantify vascular dynamics not possible using current fluorescein angiography approaches. This can be applied in both laboratory and clinical settings for in vivo dynamic fluorescent imaging of vasculature.