  • Item
    No Preview Available
    Establishing the Calibration Curve of a Compressive Ophthalmodynamometry Device.
    Kaplan, MA ; Bui, BV ; Ayton, LN ; Nguyen, B ; Grayden, DB ; John, S (IEEE, 2023-07)
    The relationship between externally applied force and intraocular pressure was determined using an ex-vivo porcine eye model (N=9). Eyes were indented through the sclera with a convex ophthalmodynamometry head (ODM). Intraocular pressure and ophthalmodynamometric force were simultaneously recorded to establish a calibration curve of this indenter head. A calibration coefficient of 0.140 ± 0.009 mmHg/mN was established and was shown to be highly linear (r = 0.998 ± 0.002). Repeat application of ODM resulted in a 0.010 ± 0.002 mmHg/mN increase to the calibration coefficient.Clinical Relevance- ODM has been highlighted as a potential method of non-invasively estimating intracranial pressure. This study provides relevant data for the practical performance of ODM with similar compressive devices.
  • Item
    No Preview Available
    Non-Invasive Measurement of Intracranial Pressure Through Application of Venous Ophthalmodynamometry.
    Lo, L ; Zhao, D ; Ayton, L ; Grayden, D ; Bui, B ; Morokoff, A ; John, S (IEEE, 2021-11)
    Non-invasive intracranial pressure (ICP) monitoring is possible using venous ophthalmodynamometry to observe a pulsation in retinal blood vessels when intraocular pressure (IOP) exceeds ICP. Here, we identify features in the eye - optic disc and retinal blood vessel locations - and identify pulsation in large retinal blood vessels. The relationship between force and the magnitude of pulsation is used to estimate ICP when force is applied to the eye to gradually increase IOP over time. This approach yields 77% accuracy in automatically observing vessel pulsation.Clinical Relevance - Non-invasive ICP monitoring is desirable to improve patient outcome by reducing potential trauma and complications associated with invasive assessment with intracranial sensors or lumbar puncture.
  • Item
    Thumbnail Image
    Focal Activation of Primary Visual Cortex Following Supra-choroidal Electrical Stimulation of the Retina: Intrinsic Signal Imaging and Linear Model Analysis
    Cloherty, SL ; Hietanen, MA ; Suaning, GJ ; Ibbotson, MR (IEEE, 2010)
    UNLABELLED: We performed optical intrinsic signal imaging of cat primary visual cortex (Area 17 and 18) while delivering bipolar electrical stimulation to the retina by way of a supra-choroidal electrode array. Using a general linear model (GLM) analysis we identified statistically significant (p < 0.01) activation in a localized region of cortex following supra-threshold electrical stimulation at a single retinal locus. OUR RESULTS: (1) demonstrate that intrinsic signal imaging combined with linear model analysis provides a powerful tool for assessing cortical responses to prosthetic stimulation, and (2) confirm that supra-choroidal electrical stimulation can achieve localized activation of the cortex consistent with focal activation of the retina.
  • Item
    Thumbnail Image
    Epiretinal Electrical Stimulation and the Inner Limiting Membrane in Rat Retina
    Cloherty, SL ; Wong, RCS ; Hadjinicolaou, AE ; Meffin, H ; Ibbotson, MR ; O'Brien, BJ (IEEE, 2012)
    In this paper we aim to quantify the effect of the inner limiting membrane (ILM) of the retina on the thresholds for epiretinal electrical stimulation of retinal ganglion cells by a microelectronic retinal prosthesis. A pair of bipolar stimulating electrodes was placed either above (on the epiretinal surface) or below the ILM while we made whole-cell patch-clamp recordings from retinal ganglion cells in an isolated rat retinal whole-mount preparation. Across our cell population we found no significant difference in the median threshold stimulus amplitudes when the stimulating electrodes were placed below as opposed to above the ILM (p = 0.08). However, threshold stimulus amplitudes did tend to be lower when the stimulating electrodes were placed below the ILM (30 µA vs 56 µA).
  • Item
    Thumbnail Image
    Retinal ganglion cells electrophysiology: the effect of cell morphology on impulse waveform
    Maturana, MI ; Wong, R ; Cloherty, SL ; Ibbotson, MR ; Hadjinicolaou, AE ; Grayden, DB ; Burkitt, AN ; Meffin, H ; O'Brien, BJ ; Kameneva, T (IEEE, 2013)
    There are 16 morphologically defined classes of rats retinal ganglion cells (RGCs). Using computer simulation of a realistic anatomically correct A1 mouse RGC, we investigate the effect of the cell's morphology on its impulse waveform, using the first-, and second-order time derivatives as well as the phase plot features. Using whole cell patch clamp recordings, we recorded the impulse waveform for each of the rat RGCs types. While we found some clear differences in many features of the impulse waveforms for A2 and B2 cells compared to other cell classes, many cell types did not show clear differences.