Obstetrics and Gynaecology - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 45
  • Item
    Thumbnail Image
    The effect of skin-to-skin care on cerebral oxygenation during nasogastric feeding of preterm infants
    Marulli, A ; Kamlin, COF ; Dawson, JA ; Donath, SM ; Davis, PG ; Lorenz, L (WILEY, 2018-03)
    AIM: To describe cerebral oxygenation during gavage feeding of preterm infants during incubator and skin-to-skin care. METHODS: Further analysis of data from two crossover studies comparing cerebral oxygenation, heart rate and oxygen saturation during skin-to-skin care with incubator care. Data were analysed in three epochs; 10 minutes prefeed, during-feed and 10 minutes postfeed. Measurements from infants fed during incubator care were compared with those obtained during skin-to-skin care. RESULTS: In 39 infants [median (IQR) 27.8 (26.1-30.0) weeks' gestation], there was no difference in cerebral oxygenation between pre-, during- and postfeed. Heart rate increased by three beats per minute postfeed compared with during-feed. Twenty infants received two gavage feeds, one feed in the incubator and another during skin-to-skin care. There was no difference in cerebral oxygenation and heart rate; peripheral oxygen saturation decreased by 3% during feeding whilst skin-to-skin care compared with feeding in the incubator. CONCLUSION: Cerebral oxygenation remained stable before, during and after gavage feeding in an incubator and during skin-to-skin care. The small decrease in oxygen saturation whilst receiving gavage feeding during skin-to-skin care is unlikely to be clinically important, providing reassurance that preterm infants maintain physiological stability during skin-to-skin care.
  • Item
    Thumbnail Image
    Nonpublication and discontinuation of randomised controlled trials in newborns
    Ruegger, CM ; Dawson, JA ; Donath, SM ; Owen, LS ; Davis, PG (WILEY, 2017-12)
    AIM: To determine the rate of nonpublication and discontinuation of randomised controlled trials (RCTs) in newborns. METHODS: This was a retrospective, cross-sectional study of RCTs registered with the Australian and New Zealand Clinical Trials Registry (ANZCTR) between 2008 and 2012. RESULTS: Fifty trials were identified, of which 23 (46%) were retrospectively registered. Thirty trials (60%) were published. After a median follow-up of 8.0 (range 4.6-17.4) years from Research Ethics Committee approval, 15 of 41 completed trials (37%) remained unpublished, representing 5422 neonatal trial participants. Nine trials (18%) were discontinued, including four that were published. The most frequent reason for discontinuation was poor recruitment (n = 4). Sample size discrepancies between registration and publication were found in 17 (65%) of the 26 completed, published trials. In nine (35%) of these trials, the calculated sample size in the method section of the published article differed from the planned sample size in the trial registry (relative difference -20% to +33%). CONCLUSION: Nonpublication and discontinuation of RCTs conducted in newborns is common. Additional efforts are needed to minimise the number of neonatal trial participants that are exposed to interventions without subsequent publication.
  • Item
    Thumbnail Image
    Very preterm birth before arrival at hospital
    Boland, RA ; Davis, PG ; Dawson, JA ; Stewart, MJ ; Smith, J ; Doyle, LW (WILEY, 2018-04)
    BACKGROUND: Our aim was to report perinatal characteristics of very preterm births before arrival (BBAs) at a hospital, and perinatal and infant mortality rates up to one year, comparing BBAs with births in a hospital. MATERIALS AND METHODS: A population-based cohort study of 22-31 weeks' gestation births in the state of Victoria, Australia from 1990-2009. BBAs were defined as unintentional births at home or on route to hospital. Perinatal data were obtained from the Department of Health and Human Services, Victoria. Perinatal and infant mortality data comparing BBAs with births in hospitals were analysed by logistic regression, adjusted for gestational age, birthweight and sex. RESULTS: One hundred and thirty-three BBAs were recorded: 51 (38%) stillbirths and 82 (62%) livebirths. Compared with births in a hospital, BBAs were less mature (26.3 weeks (SD 2.9) vs 27.7 weeks (SD 2.8), P < 0.001) and a higher proportion were born to teenagers: 13% versus 5% (adjusted odds ratio (aOR) 2.86, P < 0.001). BBAs were significantly more likely to be stillborn (aOR 2.13, 95% confidence interval (CI) 1.41, 3.23, P < 0.001) die within 28 days of livebirth (aOR 2.97, 95% CI 1.54, 5.73, P = 0.001) or die within a year of livebirth (aOR 2.87, 95% CI 1.51, 5.46, P = 0.001) compared with hospital births. Overall, 54 BBAs survived to one year (41% all BBAs, 67% liveborn BBAs), compared with 69% of hospital births (87% of livebirths). CONCLUSIONS: Very preterm birth before arrival is more common in teenagers and is associated with significantly increased risks of perinatal and infant mortality compared with birth in a hospital.
  • Item
    Thumbnail Image
    Cord stripping in preterm neonates
    Davis, PG ; Manley, BJ ; Owen, LS (WILEY, 2017-07)
  • Item
    Thumbnail Image
    A systematic review of novel technology for monitoring infant and newborn heart rate
    Kevat, AC ; Bullen, DVR ; Davis, PG ; Kamlin, COF (WILEY, 2017-05)
    UNLABELLED: Heart rate (HR) is a vital sign for assessing the need for resuscitation. We performed a systematic review of studies assessing novel methods of measuring HR in newborns and infants in the neonatal unit. Two investigators completed independent literature searches. Identified papers were independently evaluated, and relevant data were extracted and analysed. CONCLUSION: This systematic review identified seven new technologies, including camera-based photoplethysmography, reflectance pulse oximetry, laser Doppler methods, capacitive sensors, piezoelectric sensors, electromyography and a digital stethoscope. Clinicians should be aware of several of these, which may become available for clinical use in the near future.
  • Item
    Thumbnail Image
    Personal smartphones for neonatal diagnostic imaging: A prospective crossover study
    Westberg, M ; Vasko, T ; Owen, LS ; Bhatia, R ; Lluch, MT ; Donath, S ; Davis, PG ; Dawson, JA (WILEY, 2017-04)
    AIM: Neonatal clinicians may be asked to review X-ray images when unable to directly access the original image. Transmitting an X-ray image to a smartphone is a technique increasingly being used by clinicians in a number of settings. Minimal data exist on its use in the neonatal setting. Our aim was to compare the ability of neonatal clinicians to correctly diagnose a pneumothorax from a chest radiograph (CXR) viewed on a smartphone, paralleled with the same image viewed on a computer screen. METHODS: We investigated the accuracy, sensitivity, specificity, positive predictive value and negative predicative value of two methods of viewing CXR images to diagnose pneumothorax, compared with a gold standard radiologist report. Clinicians were presented with 40 CXR images on two occasions, at least 1 week apart. Images were viewed once on a smartphone and once on a computer screen. Both the viewing method and viewing order of the images were randomised. The clinical details of the infant at the time the CXR was taken were provided, and participants were asked if a pneumothorax was present. RESULTS: Twenty-one clinicians viewed all CXR images using both viewing methods (840 paired observations). There was no difference in accuracy of detecting pneumothorax between viewing methods, 81% correctly identified a pneumothorax using the smartphone, versus 80% using the computer screen (P = 0.40 (95% CI), difference -4 to 1.5%). CONCLUSION: Diagnosis of neonatal pneumothorax was as accurate using a smartphone as viewing CXR images displayed on a computer screen when clinicians were presented with X-rays with diagnosis of pneumothorax.
  • Item
    Thumbnail Image
    Clinicians in 25 countries prefer to use lower levels of oxygen to resuscitate preterm infants at birth
    Oei, JL ; Ghadge, A ; Coates, E ; Wright, IM ; Saugstad, OD ; Vento, M ; Buonocore, G ; Nagashima, T ; Suzuki, K ; Hosono, S ; Davis, PG ; Craven, P ; Askie, L ; Dawson, J ; Garg, S ; Keech, A ; Rabi, Y ; Smyth, J ; Sinha, S ; Stenson, B ; Lui, K ; Hunter, CL ; Mordi, WT (WILEY, 2016-09)
    AIM: This study determined current international clinical practice and opinions regarding initial fractional inspired oxygen (FiO2 ) and pulse oximetry (SpO2 ) targets for delivery room resuscitation of preterm infants of less than 29 weeks of gestation. METHODS: An online survey was disseminated to neonatal clinicians via established professional clinical networks using a web-based survey programme between March 9 and June 30, 2015. RESULTS: Of the 630 responses from 25 countries, 60% were from neonatologists. The majority (77%) would target SpO2 between the 10th to 50th percentiles values for full-term infants. The median starting FiO2 was 0.3, with Japan using the highest (0.4) and the UK using the lowest (0.21). New Zealand targeted the highest SpO2 percentiles (median 50%). Most respondents agreed or did not disagree that a trial was required that compared the higher FiO2 of 0.6 (83%), targeting the 50th SpO2 percentile (60%), and the lower FiO2 of 0.21 (80%), targeting the 10th SpO2 percentile (78%). Most (65%) would join this trial. Many considered that evidence was lacking and further research was needed. CONCLUSION: Clinicians currently favour lower SpO2 targets for preterm resuscitation, despite acknowledging the lack of evidence for benefit or harm, and 65% would join a clinical trial.
  • Item
    Thumbnail Image
    The accuracy of delivery of target pressures using self-inflating bag manometers in a benchtop study
    Rafferty, AR ; Johnson, L ; Maxfield, D ; Dawson, JA ; Davis, PG ; Thio, M (WILEY, 2016-06)
    AIM: We tested whether operators using manometers attached to self-inflating bags could accurately deliver set targeted peak inspiratory pressures (PIPs) compared to the Neopuff(™) T-piece resuscitator (TPR). METHODS: Participants provided positive pressure ventilation to a leak-free neonatal test lung at a rate of 60 inflations/min and a flow of 8 L/min. Participants used three manometers attached to self-inflating bags and a Neopuff(™) TPR to target PIPs of 20, 30 and 40 cmH2 O on each device. Mean PIPs delivered with each manometer were compared to the 'gold standard' Neopuff(™) TPR. RESULTS: In total, 13 991 inflations delivered by 20 participants were analysed. At all target PIPs, the mean PIP delivered using the Mercury Medical manometer attached to a Laerdal self-inflating bag was significantly higher by 5 cmH2 O (p < 0.01) than the Neopuff(™) TPR. The PIP delivered using both the Ambu(™) and Parker Healthcare manometers attached to their respective devices was similar to that delivered by the Neopuff(™) TPR at all targeted PIPs. CONCLUSION: Accurately targeted PIPs can be achieved when a manometer specifically designed for use on a self-inflating bag is used during manual ventilation. This may be useful in settings where access to a Neopuff(™) TPR or a gas flow source is limited.
  • Item
    Thumbnail Image
    Inflammation, lipids and aortic intima-media thickness in newborns following chorioamnionitis
    Rafferty, AR ; McGrory, L ; Cheung, M ; Rogerson, S ; Ziannino, D ; Pyman, J ; Davis, PG ; Burgner, D (WILEY, 2016-07)
    AIM: This study investigated whether chorioamnionitis was associated with increased inflammation, dyslipidaemia and adverse cardiovascular phenotypes in the immediate postnatal period. METHODS: This prospective case-control study included preterm infants (30(+0) -35(+6) weeks gestational age, GA) whose mothers did not have pregnancy-related conditions that may influence outcomes. Chorioamnionitis was diagnosed by placental histology, and infants were divided retrospectively into cases (chorioamnionitis-exposed) and controls (unexposed). Serum high-sensitivity C-reactive protein (hsCRP), lipid profile, far-wall abdominal aortic intima-media thickness (aIMT) and blood pressure (BP) were measured in the first week of life. RESULTS: There were 20 (16 male, mean GA 32.4 weeks) cases and 31 (12 male, mean GA 32.6 weeks) controls. Histological chorioamnionitis was associated with a significant increase in hsCRP and a non-significant trend towards an adverse lipid profile. There was no evidence of differences in aIMT or BP. CONCLUSION: Preterm infants exposed to chorioamnionitis have greater postnatal inflammation. There were no early postnatal differences in aIMT or BP. The inflammatory stimulus of chorioamnionitis late in gestation may be of insufficient intensity and duration to result in immediate postnatal alterations to arterial structure. Cardiovascular follow-up of infants exposed to chorioamnionitis may identify differential risk trajectories and subsequent inflammatory responses.
  • Item
    Thumbnail Image
    Lung ultrasound accurately detects pneumothorax in a preterm newborn lamb model
    Blank, DA ; Hooper, SB ; Binder-Heschl, C ; Kluckow, M ; Gill, AW ; LaRosa, DA ; Inocencio, IM ; Moxham, A ; Rodgers, K ; Zahra, VA ; Davis, PG ; Polglase, GR (WILEY, 2016-06)
    AIM: Pneumothorax is a common emergency affecting extremely preterm. In adult studies, lung ultrasound has performed better than chest x-ray in the diagnosis of pneumothorax. The purpose of this study was to determine the efficacy of lung ultrasound (LUS) examination to detect pneumothorax using a preterm animal model. METHODS: This was a prospective, observational study using newborn Border-Leicester lambs at gestational age = 126 days (equivalent to gestational age = 26 weeks in humans) receiving mechanical ventilation from birth to 2 h of life. At the conclusion of the experiment, LUS was performed, the lambs were then euthanised and a post-mortem exam was immediately performed. We used previously published ultrasound techniques to identify pneumothorax. Test characteristics of LUS to detect pneumothorax were calculated, using the post-mortem exam as the 'gold standard' test. RESULTS: Nine lambs (18 lungs) were examined. Four lambs had a unilateral pneumothorax, all of which were identified by LUS with no false positives. CONCLUSIONS: This was the first study to use post-mortem findings to test the efficacy of LUS to detect pneumothorax in a newborn animal model. Lung ultrasound accurately detected pneumothorax, verified by post-mortem exam, in premature, newborn lambs.