Mechanical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 660
  • Item
    Thumbnail Image
    Feasibility and performance analysis of hybrid ground source heat pump systems in fourteen cities
    Weeratunge, H ; Aditya, GR ; Dunstall, S ; de Hoog, J ; Narsilio, G ; Halgamuge, S (PERGAMON-ELSEVIER SCIENCE LTD, 2021-11-01)
    Ground source heat pump systems (GSHP) for residential building heating, cooling, and hot water are highly energy efficient but capital intensive when sized for peak demands. The use of supplemental sources of energy with GSHP systems enables improved life-cycle economics through the reduction in the size and cost of the GSHP components. This paper investigates the life-cycle economics of hybrid solar-assisted ground source heat pump systems (SAGSHP) using simulations validated from field data. The economics and optimal sizing of SAGSHP systems for heating dominant climates in four locations in Australia and ten locations elsewhere are evaluated in order to explore the suitability and relative merits of SAGSHP systems in a range of heating dominant climates. In locations having high or moderate levels of solar irradiation, high electricity prices, and high or moderate gas prices, SAGSHP systems are shown to have the lowest life cycle cost amongst alternatives, with predicted savings of up to 30%.
  • Item
    Thumbnail Image
    Experimental investigation of boundary layer transition in flow past a bluff body
    Deshpande, R ; Desai, A ; Kanti, V ; Mittal, S ; Tso, CP (Institute of Physics (IoP), 2017-01-01)
    We explore the phenomenon of drag crisis observed for the flow over bluff bodies at high Reynolds numbers. The drag coefficient reduces significantly beyond a certain Re due to the transition of the boundary layer from laminar to turbulent state. Flow past a smooth sphere and a circular cylinder is experimentally investigated for 1.0 × 105 ≤ Re ≤ 5.0 × 105 via unsteady force, surface-pressure and 2-D Particle Image Velocimetry(PIV) measurements. In case of a smooth sphere, the drag crisis is observed for Re > 3.3 × 105. The unsteady force measurements reveal that the fluctuations in the force coefficients initially increase with Re in the high subcritical regime and then experience a steep fall in the critical regime. It is found from the PIV measurements that the normal Reynolds stresses in the separated shear layer from the sphere are one order lower in magnitude for the supercritical regime in comparison to the subcritical regime. In the case of flow past a smooth circular cylinder, a two-stage drag crisis is captured using surface-pressure measurements where the boundary layer over one side of the cylinder undergoes transition around Re = 3.9 × 105 and that over the second side transitions around Re = 4.8 × 105. The transition is accompanied with increased fluctuations in the surface-pressure coefficients near the shoulders of the cylinder.
  • Item
    Thumbnail Image
    Effects of Prophylactic Knee Bracing on Lower Limb Kinematics, Kinetics, and Energetics During Double-Leg Drop Landing at 2 Heights
    Ewing, KA ; Begg, RK ; Galea, MP ; Lee, PVS (SAGE PUBLICATIONS INC, 2016-07)
    BACKGROUND: Anterior cruciate ligament (ACL) injuries commonly occur during landing maneuvers. Prophylactic knee braces were introduced to reduce the risk of ACL injuries, but their effectiveness is debated. HYPOTHESES: We hypothesized that bracing would improve biomechanical factors previously related to the risk of ACL injuries, such as increased hip and knee flexion angles at initial contact and at peak vertical ground-reaction force (GRF), increased ankle plantar flexion angles at initial contact, decreased peak GRFs, and decreased peak knee extension moment. We also hypothesized that bracing would increase the negative power and work of the hip joint and would decrease the negative power and work of the knee and ankle joints. STUDY DESIGN: Controlled laboratory study. METHODS: Three-dimensional motion and force plate data were collected from 8 female and 7 male recreational athletes performing double-leg drop landings from 0.30 m and 0.60 m with and without a prophylactic knee brace. GRFs, joint angles, moments, power, and work were calculated for each athlete with and without a knee brace. RESULTS: Prophylactic knee bracing increased the hip flexion angle at peak GRF by 5.56° (P < .001), knee flexion angle at peak GRF by 4.75° (P = .001), and peak hip extension moment by 0.44 N·m/kg (P < .001). Bracing also increased the peak hip negative power by 4.89 W/kg (P = .002) and hip negative work by 0.14 J/kg (P = .001) but did not result in significant differences in the energetics of the knee and ankle. No differences in peak GRFs and peak knee extension moment were observed with bracing. CONCLUSION: The application of a prophylactic knee brace resulted in improvements in important biomechanical factors associated with the risk of ACL injuries. CLINICAL RELEVANCE: Prophylactic knee braces may help reduce the risk of noncontact knee injuries in recreational and professional athletes while playing sports. Further studies should investigate different types of prophylactic knee braces in conjunction with existing training interventions so that the sports medicine community can better assess the effectiveness of prophylactic knee bracing.
  • Item
    Thumbnail Image
    Prophylactic knee bracing alters lower-limb muscle forces during a double-leg drop landing
    Ewing, KA ; Fernandez, JW ; Begg, RK ; Galea, MP ; Lee, PVS (ELSEVIER SCI LTD, 2016-10-03)
    Anterior cruciate ligament (ACL) injury can be a painful, debilitating and costly consequence of participating in sporting activities. Prophylactic knee bracing aims to reduce the number and severity of ACL injury, which commonly occurs during landing maneuvers and is more prevalent in female athletes, but a consensus on the effectiveness of prophylactic knee braces has not been established. The lower-limb muscles are believed to play an important role in stabilizing the knee joint. The purpose of this study was to investigate the changes in lower-limb muscle function with prophylactic knee bracing in male and female athletes during landing. Fifteen recreational athletes performed double-leg drop landing tasks from 0.30m and 0.60m with and without a prophylactic knee brace. Motion analysis data were used to create subject-specific musculoskeletal models in OpenSim. Static optimization was performed to calculate the lower-limb muscle forces. A linear mixed model determined that the hamstrings and vasti muscles produced significantly greater flexion and extension torques, respectively, and greater peak muscle forces with bracing. No differences in the timings of peak muscle forces were observed. These findings suggest that prophylactic knee bracing may help to provide stability to the knee joint by increasing the active stiffness of the hamstrings and vasti muscles later in the landing phase rather than by altering the timing of muscle forces. Further studies are necessary to quantify whether prophylactic knee bracing can reduce the load placed on the ACL during intense dynamic movements.
  • Item
    Thumbnail Image
    Effect Of Arm Deweighting Using End-Effector Based Robotic Devices On Muscle Activity.
    Fong, J ; Crocher, V ; Haddara, R ; Ackland, D ; Galea, M ; Tan, Y ; Oetomo, D (IEEE, 2018)
    Deweighting of the limb is commonly performed for patients with a neurological injury, such as stroke, as it allows these patients with limited muscle activity to perform movements. Deweighting has been implemented in exoskeletons and other multi-contact devices, but not on an end-effector based device with single contact point between the assisting robot and the human limb being assisted. This study inves-tigates the effects of deweighting using an end-effector based device on healthy subjects. The muscle activity of five subjects was measured in both static postures and dynamic movements. The results indicate a decrease in the activity of muscles which typically act against gravity - such as the anterior deltoid and the biceps brachii - but also suggest an increase in activity in muscles which act with gravity - such as the posterior deltoid and the lateral triceps. This can be explained by both the change in required muscle-generated torques and a conscious change in approach by the participants. These observations have implications for neurorehabilitation, particularly with respect to the muscle activation patterns which are trained through rehabilitation exercises.
  • Item
    Thumbnail Image
    Promoting clinical best practice in a user-centred design study of an upper limb rehabilitation robot
    Fong, J ; Crocher, V ; Klaic, M ; Davies, K ; Rowse, A ; Sutton, E ; Tan, Y ; Oetomo, D ; Brock, K ; Galea, MP (Taylor & Francis, 2021-01-01)
    Purpose: Despite their promise to increase therapy intensity in neurorehabilitation, robotic devices have not yet seen mainstream adoption. Whilst there are a number of contributing factors, it is obvious that the treating clinician should have a clear understanding of the objectives and limitations of robotic device use. This study sought to explore how devices can be developed to support a clinician in providing clinical best practice. Methods and Materials: A user-centred design study of a robotic device was conducted, involving build-then-use iterations, where successive iterations are built based on feedback from the use cycle. This work reports results of an analysis of qualitative and quantitative data describing the use of the robotic device in the clinical sessions, and from a focus group with the treating clinicians. Results and Conclusions: The data indicated that use of the device did not result in patient goal-setting and may have resulted in poor movement quality. Therapists expected a higher level of autonomy from the robotic device, and this may have contributed to the above problems. These problems can and should be addressed through modification of both the study design and device to provide more explicit instructions to promote clinical best practice. Implications for Rehabilitation: • Encouraging clinical best practice when using evaluating prototype devices within a clinical setting is important to ensure that best practice is maintained - and can be achieved through both study and device design • Support from device developers can significantly improve the confidence of therapists during the use of that device in rehabilitation, particularly with new or prototype devices • End effector-based robotic devices for rehabilitation show potential for a wide variety of patient presentations and capabilities.
  • Item
    Thumbnail Image
    Evaluating Rehabilitation Progress Using Motion Features Identified by Machine Learning
    Lu, L ; Tan, Y ; Klaic, M ; Galea, MP ; Khan, F ; Oliver, A ; Mareels, I ; Oetomo, D ; Zhao, E (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2021-04)
    Evaluating progress throughout a patient's rehabilitation episode is critical for determining the effectiveness of the selected treatments and is an essential ingredient in personalised and evidence-based rehabilitation practice. The evaluation process is complex due to the inherently large human variations in motor recovery and the limitations of commonly used clinical measurement tools. Information recorded during a robot-assisted rehabilitation process can provide an effective means to continuously quantitatively assess movement performance and rehabilitation progress. However, selecting appropriate motion features for rehabilitation evaluation has always been challenging. This paper exploits unsupervised feature learning techniques to reduce the complexity of building the evaluation model of patients' progress. A new feature learning technique is developed to select the most significant features from a large amount of kinematic features measured from robotics, providing clinically useful information to health practitioners with reduction of modeling complexity. A novel indicator that uses monotonicity and trendability is proposed to evaluate kinematic features. The data used to develop the feature selection technique consist of kinematic data from robot-aided rehabilitation for a population of stroke patients. The selected kinematic features allow for human variations across a population of patients as well as over the sequence of rehabilitation sessions. The study is based on data records pertaining to 41 stroke patients using three different robot assisted exercises for upper limb rehabilitation. Consistent with the literature, the results indicate that features based on movement smoothness are the best measures among 17 kinematic features suitable to evaluate rehabilitation progress.
  • Item
    No Preview Available
    Uncertainty quantification and reduction using sensitivity analysis and Hessian derivatives
    Sánchez, J ; Otto, K (American Society of Mechanical Engineers, 2021-01-01)
    Abstract We study the use of Hessian interaction terms to quickly identify design variables that reduce variability of system performance. To start we quantify the uncertainty and compute the variance decomposition to determine noise variables that contribute most, all at an initial design. Minimizing the uncertainty is next sought, though probabilistic optimization becomes computationally difficult, whether by including distribution parameters as an objective function or through robust design of experiments. Instead, we consider determining the more easily computed Hessian interaction matrix terms of the variance-contributing noise variables and the variables of any proposed design change. We also relate the Hessian term coefficients to subtractions in Sobol indices and reduction in response variance. Design variable changes that can reduce variability are thereby identified quickly as those with large Hessian terms against noise variables. Furthermore, the Jacobian terms of these design changes can indicate which design variables can shift the mean response, to maintain a desired nominal performance target. Using a combination of easily computed Hessian and Jacobian terms, design changes can be proposed to reduce variability while maintaining a targeted nominal. Lastly, we then recompute the uncertainty and variance decomposition at the more robust design configuration to verify the reduction in variability. This workflow therefore makes use of UQ/SA methods and computes design changes that reduce uncertainty with a minimal 4 runs per design change. An example is shown on a Stirling engine design where the top four variance-contributing tolerances are matched with two design changes identified through Hessian terms, and a new design found with 20% less variance.
  • Item
    No Preview Available
  • Item
    No Preview Available
    The wrinkling and buckling of graphene induced by nanotwinned copper matrix: A molecular dynamics study
    Zhang, C ; Lu, C ; Pei, L ; Li, J ; Wang, R (KEAI PUBLISHING LTD, 2021-03)