Mechanical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 6 of 6
  • Item
    Thumbnail Image
    Flexible mechanical metamaterials enabling soft tactile sensors with multiple sensitivities at multiple force sensing ranges
    Mohammadi, A ; Tan, Y ; Choong, P ; Oetomo, D (NATURE PORTFOLIO, 2021-12-16)
    The majority of existing tactile sensors are designed to measure a particular range of force with a fixed sensitivity. However, some applications require tactile sensors with multiple task-relevant sensitivities at multiple ranges of force sensing. Inspired by the human tactile sensing capability, this paper proposes a novel soft tactile sensor based on mechanical metamaterials which exhibits multiple sensitivity regimes due to the step-by-step locking behaviour of its heterogenous multi-layered structure. By tuning the geometrical design parameters of the collapsible layers, each layer experiences locking behaviour under different ranges of force which provides different sensitivity of the sensor at different force magnitude. The integration of a magnetic-based transduction method with the proposed structure results in high design degrees of freedom for realising the desired contact force sensitivities and corresponding force sensing ranges. A systematic design procedure is proposed to select appropriate design parameters to produce the desired characteristics. Two example designs of the sensor structure were fabricated using widely available benchtop 3D printers and tested for their performance. The results showed the capability of the sensor in providing the desired characteristics in terms of sensitivity and force range and being realised in different shapes, sizes and number of layers in a single structure. The proposed multi-sensitivity soft tactile sensor has a great potential to be used in a wide variety of applications where different sensitivities of force measurement is required at different ranges of force magnitudes, from robotic manipulation and human-machine interaction to biomedical engineering and health-monitoring.
  • Item
    Thumbnail Image
    On the Efficiency of Haptic Based Object Identification: Determining Where to Grasp to Get the Most Distinguishing Information
    Xia, Y ; Mohammadi, A ; Tan, Y ; Chen, B ; Choong, P ; Oetomo, D (FRONTIERS MEDIA SA, 2021-07-29)
    Haptic perception is one of the key modalities in obtaining physical information of objects and in object identification. Most existing literature focused on improving the accuracy of identification algorithms with less attention paid to the efficiency. This work aims to investigate the efficiency of haptic object identification to reduce the number of grasps required to correctly identify an object out of a given object set. Thus, in a case where multiple grasps are required to characterise an object, the proposed algorithm seeks to determine where the next grasp should be on the object to obtain the most amount of distinguishing information. As such, the paper proposes the construction of the object description that preserves the association of the spatial information and the haptic information on the object. A clustering technique is employed both to construct the description of the object in a data set and for the identification process. An information gain (IG) based method is then employed to determine which pose would yield the most distinguishing information among the remaining possible candidates in the object set to improve the efficiency of the identification process. This proposed algorithm is validated experimentally. A Reflex TakkTile robotic hand with integrated joint displacement and tactile sensors is used to perform both the data collection for the dataset and the object identification procedure. The proposed IG approach was found to require a significantly lower number of grasps to identify the objects compared to a baseline approach where the decision was made by random choice of grasps.
  • Item
    Thumbnail Image
    Comparison of posterior-stabilized, cruciate-retaining, and medial-stabilized knee implant motion during gait.
    Gray, HA ; Guan, S ; Young, TJ ; Dowsey, MM ; Choong, PF ; Pandy, MG (Wiley, 2020-08)
    Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.
  • Item
    Thumbnail Image
    A Randomized Controlled Trial Comparing a Medial Stabilised Total Knee Prosthesis to a Cruciate Retaining and Posterior Stabilised Design - A Report of the Clinical and Functional Outcomes Following Total Knee Replacement
    Dowsey, MM ; Gould, D ; Spelman, T ; Pandy, MG ; Choong, PF (Elsevier BV, 2020-06)
    Background The purpose of this randomized controlled trial was to compare the performance of 3 total knee joint replacement (TKJR) designs 6 months after the surgery. Methods Patients were recruited between March 2015 and March 2018. Patients with osteoarthritis consented for TKJR were randomly allocated to a medial stabilized (MS), cruciate retaining (CR), or posterior stabilized (PS) design. Primary outcome measures were self-reported improvement in pain and function 6 months after TKJR, using the Oxford Knee Score. Secondary outcome measures were the Western Ontario and McMaster Universities Osteoarthritis Index, Veterans RAND 12-item Health Survey, Knee Society Score 2011, Timed Up and Go test, and Six-Minute Walk Test. Twelve-month outcomes were also measured. Results Ninety participants enrolled, 83 were randomized: PS (n = 26), CR (n = 28), and MS (n = 29) designs. One case withdrew before surgery: planned use of non-study implant; 7 did not complete all outcome measures. No 6-month between-group difference was observed for the primary outcome. A 6-month difference was observed in Knee Society Score 2011 Satisfaction: MS favored over CR and PS. Clinically meaningful 12-month differences in Western Ontario and McMaster Universities Osteoarthritis Index Pain, Function, and Global Subscales were observed: MS favored over CR. Twelve-month differences occurred in Veterans RAND 12-item Health Survey mental well-being, favoring MS and PS over CR. Conclusion MS prosthesis can be expected to yield similar clinical and functional outcomes to PS and CR designs 6 months after TKJR, and patients were more satisfied with their outcome. Compared with CR, patients with MS prosthesis also reported superior pain, function, and quality-of-life outcomes at 12 months.
  • Item
    Thumbnail Image
    A practical 3D-printed soft robotic prosthetic hand with multi-articulating capabilities
    Mohammadi, A ; Lavranos, J ; Zhou, H ; Mutlu, R ; Alici, G ; Tan, Y ; Choong, P ; Oetomo, D ; Connal, L (Public Library of Science (PLoS), 2020-05-14)
    Soft robotic hands with monolithic structure have shown great potential to be used as prostheses due to their advantages to yield light weight and compact designs as well as its ease of manufacture. However, existing soft prosthetic hands design were often not geared towards addressing some of the practical requirements highlighted in prosthetics research. The gap between the existing designs and the practical requirements significantly hampers the potential to transfer these designs to real-world applications. This work addressed these requirements with the consideration of the trade-off between practicality and performance. These requirements were achieved through exploiting the monolithic 3D printing of soft materials which incorporates membrane enclosed flexure joints in the finger designs, synergy-based thumb motion and cable-driven actuation system in the proposed hand prosthesis. Our systematic design (tentatively named X-Limb) achieves a weight of 253gr, three grasps types (with capability of individual finger movement), power-grip force of 21.5N, finger flexion speed of 1.3sec, a minimum grasping cycles of 45,000 (while maintaining its original functionality) and a bill of material cost of 200 USD (excluding quick disconnect wrist but without factoring in the cost reduction through mass production). A standard Activities Measure for Upper-Limb Amputees benchmark test was carried out to evaluate the capability of X-Limb in performing grasping task required for activities of daily living. The results show that all the practical design requirements are satisfied, and the proposed soft prosthetic hand is able to perform all the real-world grasping tasks of the benchmark tests, showing great potential in improving life quality of individuals with upper limb loss.
  • Item
    Thumbnail Image
    Tactile Feedback in Closed-Loop Control of Myoelectric Hand Grasping: Conveying Information of Multiple Sensors Simultaneously via a Single Feedback Channel.
    Mayer, RM ; Garcia-Rosas, R ; Mohammadi, A ; Tan, Y ; Alici, G ; Choong, P ; Oetomo, D (Frontiers Research Foundation, 2020-04-27)
    The appropriate sensory information feedback is important for the success of an object grasping and manipulation task. In many scenarios, the need arises for multiple feedback information to be conveyed to a prosthetic hand user simultaneously. The multiple sets of information may either (1) directly contribute to the performance of the grasping or object manipulation task, such as the feedback of the grasping force, or (2) simply form additional independent set(s) of information. In this paper, the efficacy of simultaneously conveying two independent sets of sensor information (the grasp force and a secondary set of information) through a single channel of feedback stimulation (vibrotactile via bone conduction) to the human user in a prosthetic application is investigated. The performance of the grasping task is not dependent to the second set of information in this study. Subject performance in two tasks: regulating the grasp force and identifying the secondary information, were evaluated when provided with either one corresponding information or both sets of feedback information. Visual feedback is involved in the training stage. The proposed approach is validated on human-subject experiments using a vibrotactile transducer worn on the elbow bony landmark (to realize a non-invasive bone conduction interface) carried out in a virtual reality environment to perform a closed-loop object grasping task. The experimental results show that the performance of the human subjects on either task, whilst perceiving two sets of sensory information, is not inferior to that when receiving only one set of corresponding sensory information, demonstrating the potential of conveying a second set of information through a bone conduction interface in an upper limb prosthetic task.