Mechanical Engineering - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 10 of 13
  • Item
    No Preview Available
    A Geometry-Based Distributed Connectivity Maintenance Algorithm for Discrete-time Multi-Agent Systems with Visual Sensing Constraints
    Li, X ; Fu, J ; Liu, M ; Xu, Y ; Tan, Y ; Xin, Y ; Pu, Y ; Oetomo, D (WORLD SCIENTIFIC PUBL CO PTE LTD, 2024-03-01)
    This paper presents a novel approach to address the challenge of maintaining connectivity within a multi-agent system (MAS) when utilizing directional visual sensors. These sensors have become essential tools for enhancing communication and connectivity in MAS, but their geometric constraints pose unique challenges when designing controllers. Our approach, grounded in geometric principles, leverages a mathematical model of directional visual sensors and employs a gradient-descent optimization method to determine the position and orientation constraints for each sensor based on its geometric configuration. This methodology ensures network connectivity, provided that initial geometric constraints are met. Experimental results validate the efficacy of our approach, highlighting its practical applicability for a range of tasks within MAS.
  • Item
    No Preview Available
    On Active Disturbance Rejection Control for Unmanned Tracked Ground Vehicles with Nonsmooth Disturbances
    Liu, M ; Xu, Y ; Lin, X ; Tan, Y ; Pu, Y ; Li, W ; Oetomo, D (WORLD SCIENTIFIC PUBL CO PTE LTD, 2023-01-01)
    This paper proposes robust controllers for a class of unmanned tracked ground vehicles (UTGVs), which are built to autonomously clean carryback or spillage from the conveyor belts used in the mining industry. The UTGV, a nonholonomic system in its nature, needs to follow a given path in a harsh environment with large uncertainties due to the time-varying mass and inertia when the UTGV loads and unloads as well as unknown frictions and flatness of the ground. Moreover, the input constraints coming from motors do exist. It is usually hard to design robust controllers for such complex systems. By utilizing the available autonomous driving system, which is designed to be compatible with the existing remote motion controller in unmanned systems to generate autonomous ability, this paper uses the off-the-shelf motion planner to calculate desired linear and angular velocities based on the given path and sensor perceptions. Consequently, the control design can be simplified as two decoupled linear time-invariant scalar dynamic systems with uncertainties, making the active disturbance rejection controller (ADRC) applicable. By carefully designing the parameters of ADRC with the help of an extended state observer (ESO), it is shown that the proposed ADRC and ESO can achieve good tracking performance in the presence of input saturation and can handle nonsmooth disturbances. The proposed simulation results and experimental results support the theoretical findings.
  • Item
    Thumbnail Image
    Frequency set selection for multi-frequency steady-state visual evoked potential-based brain-computer interfaces
    Mu, J ; Grayden, DBB ; Tan, Y ; Oetomo, D (FRONTIERS MEDIA SA, 2022-12-21)
    OBJECTIVE: Multi-frequency steady-state visual evoked potential (SSVEP) stimulation and decoding methods enable the representation of a large number of visual targets in brain-computer interfaces (BCIs). However, unlike traditional single-frequency SSVEP, multi-frequency SSVEP is not yet widely used. One of the key reasons is that the redundancy in the input options requires an additional selection process to define an effective set of frequencies for the interface. This study investigates systematic frequency set selection methods. METHODS: An optimization strategy based on the analysis of the frequency components in the resulting multi-frequency SSVEP is proposed, investigated and compared to existing methods, which are constructed based on the analysis of the stimulation (input) signals. We hypothesized that minimizing the occurrence of common sums in the multi-frequency SSVEP improves the performance of the interface, and that selection by pairs further increases the accuracy compared to selection by frequencies. An experiment with 12 participants was conducted to validate the hypotheses. RESULTS: Our results demonstrated a statistically significant improvement in decoding accuracy with the proposed optimization strategy based on multi-frequency SSVEP features compared to conventional techniques. Both hypotheses were validated by the experiments. CONCLUSION: Performing selection by pairs and minimizing the number of common sums in selection by pairs are effective ways to select suitable frequency sets that improve multi-frequency SSVEP-based BCI accuracies. SIGNIFICANCE: This study provides guidance on frequency set selection in multi-frequency SSVEP. The proposed method in this study shows significant improvement in BCI performance (decoding accuracy) compared to existing methods in the literature.
  • Item
    Thumbnail Image
    Technology-assisted assessment of spasticity: a systematic review
    Guo, X ; Wallace, R ; Tan, Y ; Oetomo, D ; Klaic, M ; Crocher, V (BMC, 2022-12-09)
    BACKGROUND: Spasticity is defined as "a motor disorder characterised by a velocity dependent increase in tonic stretch reflexes (muscle tone) with exaggerated tendon jerks". It is a highly prevalent condition following stroke and other neurological conditions. Clinical assessment of spasticity relies predominantly on manual, non-instrumented, clinical scales. Technology based solutions have been developed in the last decades to offer more specific, sensitive and accurate alternatives but no consensus exists on these different approaches. METHOD: A systematic review of literature of technology-based methods aiming at the assessment of spasticity was performed. The approaches taken in the studies were classified based on the method used as well as their outcome measures. The psychometric properties and usability of the methods and outcome measures reported were evaluated. RESULTS: 124 studies were included in the analysis. 78 different outcome measures were identified, among which seven were used in more than 10 different studies each. The different methods rely on a wide range of different equipment (from robotic systems to simple goniometers) affecting their cost and usability. Studies equivalently applied to the lower and upper limbs (48% and 52%, respectively). A majority of studies applied to a stroke population (N = 79). More than half the papers did not report thoroughly the psychometric properties of the measures. Analysis identified that only 54 studies used measures specific to spasticity. Repeatability and discriminant validity were found to be of good quality in respectively 25 and 42 studies but were most often not evaluated (N = 95 and N = 78). Clinical validity was commonly assessed only against clinical scales (N = 33). Sensitivity of the measure was assessed in only three studies. CONCLUSION: The development of a large diversity of assessment approaches appears to be done at the expense of their careful evaluation. Still, among the well validated approaches, the ones based on manual stretching and measuring a muscle activity reaction and the ones leveraging controlled stretches while isolating the stretch-reflex torque component appear as the two promising practical alternatives to clinical scales. These methods should be further evaluated, including on their sensitivity, to fully inform on their potential.
  • Item
    Thumbnail Image
    Promoting clinical best practice in a user-centred design study of an upper limb rehabilitation robot
    Fong, J ; Crocher, V ; Klaic, M ; Davies, K ; Rowse, A ; Sutton, E ; Tan, Y ; Oetomo, D ; Brock, K ; Galea, MP (Taylor & Francis, 2021-01-01)
    Purpose: Despite their promise to increase therapy intensity in neurorehabilitation, robotic devices have not yet seen mainstream adoption. Whilst there are a number of contributing factors, it is obvious that the treating clinician should have a clear understanding of the objectives and limitations of robotic device use. This study sought to explore how devices can be developed to support a clinician in providing clinical best practice. Methods and Materials: A user-centred design study of a robotic device was conducted, involving build-then-use iterations, where successive iterations are built based on feedback from the use cycle. This work reports results of an analysis of qualitative and quantitative data describing the use of the robotic device in the clinical sessions, and from a focus group with the treating clinicians. Results and Conclusions: The data indicated that use of the device did not result in patient goal-setting and may have resulted in poor movement quality. Therapists expected a higher level of autonomy from the robotic device, and this may have contributed to the above problems. These problems can and should be addressed through modification of both the study design and device to provide more explicit instructions to promote clinical best practice. Implications for Rehabilitation: • Encouraging clinical best practice when using evaluating prototype devices within a clinical setting is important to ensure that best practice is maintained - and can be achieved through both study and device design • Support from device developers can significantly improve the confidence of therapists during the use of that device in rehabilitation, particularly with new or prototype devices • End effector-based robotic devices for rehabilitation show potential for a wide variety of patient presentations and capabilities.
  • Item
    Thumbnail Image
    Evaluating Rehabilitation Progress Using Motion Features Identified by Machine Learning
    Lu, L ; Tan, Y ; Klaic, M ; Galea, MP ; Khan, F ; Oliver, A ; Mareels, I ; Oetomo, D ; Zhao, E (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2021-04)
    Evaluating progress throughout a patient's rehabilitation episode is critical for determining the effectiveness of the selected treatments and is an essential ingredient in personalised and evidence-based rehabilitation practice. The evaluation process is complex due to the inherently large human variations in motor recovery and the limitations of commonly used clinical measurement tools. Information recorded during a robot-assisted rehabilitation process can provide an effective means to continuously quantitatively assess movement performance and rehabilitation progress. However, selecting appropriate motion features for rehabilitation evaluation has always been challenging. This paper exploits unsupervised feature learning techniques to reduce the complexity of building the evaluation model of patients' progress. A new feature learning technique is developed to select the most significant features from a large amount of kinematic features measured from robotics, providing clinically useful information to health practitioners with reduction of modeling complexity. A novel indicator that uses monotonicity and trendability is proposed to evaluate kinematic features. The data used to develop the feature selection technique consist of kinematic data from robot-aided rehabilitation for a population of stroke patients. The selected kinematic features allow for human variations across a population of patients as well as over the sequence of rehabilitation sessions. The study is based on data records pertaining to 41 stroke patients using three different robot assisted exercises for upper limb rehabilitation. Consistent with the literature, the results indicate that features based on movement smoothness are the best measures among 17 kinematic features suitable to evaluate rehabilitation progress.
  • Item
    Thumbnail Image
    Flexible mechanical metamaterials enabling soft tactile sensors with multiple sensitivities at multiple force sensing ranges
    Mohammadi, A ; Tan, Y ; Choong, P ; Oetomo, D (NATURE PORTFOLIO, 2021-12-16)
    The majority of existing tactile sensors are designed to measure a particular range of force with a fixed sensitivity. However, some applications require tactile sensors with multiple task-relevant sensitivities at multiple ranges of force sensing. Inspired by the human tactile sensing capability, this paper proposes a novel soft tactile sensor based on mechanical metamaterials which exhibits multiple sensitivity regimes due to the step-by-step locking behaviour of its heterogenous multi-layered structure. By tuning the geometrical design parameters of the collapsible layers, each layer experiences locking behaviour under different ranges of force which provides different sensitivity of the sensor at different force magnitude. The integration of a magnetic-based transduction method with the proposed structure results in high design degrees of freedom for realising the desired contact force sensitivities and corresponding force sensing ranges. A systematic design procedure is proposed to select appropriate design parameters to produce the desired characteristics. Two example designs of the sensor structure were fabricated using widely available benchtop 3D printers and tested for their performance. The results showed the capability of the sensor in providing the desired characteristics in terms of sensitivity and force range and being realised in different shapes, sizes and number of layers in a single structure. The proposed multi-sensitivity soft tactile sensor has a great potential to be used in a wide variety of applications where different sensitivities of force measurement is required at different ranges of force magnitudes, from robotic manipulation and human-machine interaction to biomedical engineering and health-monitoring.
  • Item
    Thumbnail Image
    On the Efficiency of Haptic Based Object Identification: Determining Where to Grasp to Get the Most Distinguishing Information
    Xia, Y ; Mohammadi, A ; Tan, Y ; Chen, B ; Choong, P ; Oetomo, D (FRONTIERS MEDIA SA, 2021-07-29)
    Haptic perception is one of the key modalities in obtaining physical information of objects and in object identification. Most existing literature focused on improving the accuracy of identification algorithms with less attention paid to the efficiency. This work aims to investigate the efficiency of haptic object identification to reduce the number of grasps required to correctly identify an object out of a given object set. Thus, in a case where multiple grasps are required to characterise an object, the proposed algorithm seeks to determine where the next grasp should be on the object to obtain the most amount of distinguishing information. As such, the paper proposes the construction of the object description that preserves the association of the spatial information and the haptic information on the object. A clustering technique is employed both to construct the description of the object in a data set and for the identification process. An information gain (IG) based method is then employed to determine which pose would yield the most distinguishing information among the remaining possible candidates in the object set to improve the efficiency of the identification process. This proposed algorithm is validated experimentally. A Reflex TakkTile robotic hand with integrated joint displacement and tactile sensors is used to perform both the data collection for the dataset and the object identification procedure. The proposed IG approach was found to require a significantly lower number of grasps to identify the objects compared to a baseline approach where the decision was made by random choice of grasps.
  • Item
    Thumbnail Image
    Effective Assessments of a Short-Duration Poor Posture on Upper Limb Muscle Fatigue Before Physical Exercise
    Lu, L ; Robinson, M ; Tan, Y ; Goonewardena, K ; Guo, X ; Mareels, I ; Oetomo, D (Frontiers Media, 2020-10-06)
    A forward head and rounded shoulder posture is a poor posture that is widely seen in everyday life. It is known that sitting in such a poor posture with long hours will bring health issues such as muscle pain. However, it is not known whether sitting in this poor posture for a short period of time will affect human activities. This paper investigates the effects of a short-duration poor posture before some typical physical activities such as push-ups. The experiments are set up as follows. Fourteen male subjects are asked to do push-ups until fatigue with two surface electromyography (sEMG) at the upper limb. Two days later, they are asked to sit in this poor posture for 15 min with eight sEMG sensors located at given back muscles. Then they do the push-ups after the short-duration poor posture. The observations from the median frequency of sEMG signals at the upper limb indicate that the short-duration poor posture does affect the fatigue procedure of push-ups. A significant decreasing trend of the performance of push-ups is obtained after sitting in this poor posture. Such effects indicate that some parts of the back muscles indeed get fatigued with only 15 min sitting in this poor posture. By further investigating the time-frequency components of sEMG of back muscles, it is observed that the low and middle frequencies of sEMG signals from the infraspinatus muscle of the dominant side are demonstrated to be more prone to fatigue with the poor posture. Although this study focuses only on push-ups, similar experiments can be arranged for other physical exercises as well. This study provides new insights into the effect of a short-duration poor posture before physical activities. These insights can be used to guide athletes to pay attention to postures before physical activities to improve performance and reduce the risk of injury.
  • Item
    Thumbnail Image
    Magnetic-based Soft Tactile Sensors with Deformable Continuous Force Transfer Medium for Resolving Contact Locations in Robotic Grasping and Manipulation
    Mohammadi, A ; Xu, Y ; Tan, Y ; Choong, P ; Oetomo, D (MDPI, 2019-11)
    The resolution of contact location is important in many applications in robotics and automation. This is generally done by using an array of contact or tactile receptors, which increases cost and complexity as the required resolution or area is increased. Tactile sensors have also been developed using a continuous deformable medium between the contact and the receptors, which allows few receptors to interpolate the information among them, avoiding the weakness highlighted in the former approach. The latter is generally used to measure contact force intensity or magnitude but rarely used to identify the contact locations. This paper presents a systematic design and characterisation procedure for magnetic-based soft tactile sensors (utilizing the latter approach with the deformable contact medium) with the goal of locating the contact force location. This systematic procedure provides conditions under which design parameters can be selected, supported by a selected machine learning algorithm, to achieve the desired performance of the tactile sensor in identifying the contact location. An illustrative example, which combines a particular sensor configuration (magnetic hall effect sensor as the receptor, a selected continuous medium and a selected sensing resolution) and a specific data-driven algorithm, is used to illustrate the proposed design procedure. The results of the illustrative example design demonstrates the efficacy of the proposed design procedure and the proposed sensing strategy in identifying a contact location. The resulting sensor is also tested on a robotic hand (Allegro Hand, SimLab Co) to demonstrate its application in real-world scenarios.