Medicine (RMH) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Effect Of Arm Deweighting Using End-Effector Based Robotic Devices On Muscle Activity.
    Fong, J ; Crocher, V ; Haddara, R ; Ackland, D ; Galea, M ; Tan, Y ; Oetomo, D (IEEE, 2018)
    Deweighting of the limb is commonly performed for patients with a neurological injury, such as stroke, as it allows these patients with limited muscle activity to perform movements. Deweighting has been implemented in exoskeletons and other multi-contact devices, but not on an end-effector based device with single contact point between the assisting robot and the human limb being assisted. This study inves-tigates the effects of deweighting using an end-effector based device on healthy subjects. The muscle activity of five subjects was measured in both static postures and dynamic movements. The results indicate a decrease in the activity of muscles which typically act against gravity - such as the anterior deltoid and the biceps brachii - but also suggest an increase in activity in muscles which act with gravity - such as the posterior deltoid and the lateral triceps. This can be explained by both the change in required muscle-generated torques and a conscious change in approach by the participants. These observations have implications for neurorehabilitation, particularly with respect to the muscle activation patterns which are trained through rehabilitation exercises.
  • Item
    No Preview Available
    A Practical Post-Stroke Elbow Spasticity Assessment Using an Upper Limb Rehabilitation Robot: A Validation Study
    Guo, X ; Tang, J ; Crocher, V ; Klaic, M ; Oetomo, D ; Xie, Q ; Galea, MP ; Niu, CM ; Tan, Y (IEEE, 2022-07)
    Spasticity is a motor disorder characterised by a velocity-dependent increase in muscle tone, which is critical in neurorehabilitation given its high prevalence and potential negative influence among the post-stroke population. Accurate measurement of spasticity is important as it guides the strategy of spasticity treatment and evaluates the effectiveness of spasticity management. However, spasticity is commonly measured using clinical scales which may lack objectivity and reliability. Although many technology-assisted measures have been developed, showing their potential as accurate and reliable alternatives to standard clinical scales, they have not been widely adopted in clinical practice due to their low usability and feasibility. This paper thus introduces an easy-to-use robotic based measure of elbow spasticity and its evaluation protocol. Preliminary results collected with one post-stroke patient and one healthy control subject are presented and demonstrate the feasibility of the approach.