Medicine (RMH) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Classification of Convulsive Psychogenic Non-epileptic Seizures Using Histogram of Oriented Motion of Accelerometry Signals
    Kusmakar, S ; Gubbi, J ; Rao, AS ; Yan, B ; O'Brien, TJ ; PALANISWAMI, M (IEEE, 2015)
    A seizure is caused due to sudden surge of electrical activity within the brain. There is another class of seizures called psychogenic non-epileptic seizure (PNES) that mimics epilepsy, but is caused due to underlying psychology. The diagnosis of PNES is done using video-electroencephalography monitoring (VEM), which is a resource intensive process. Recently, accelerometers have been shown to be effective in classification of epileptic and non-epileptic seizures. In this work, we propose a novel feature called histogram of oriented motion (HOOM) extracted from accelerometer signals for classification of convulsive PNES. An automated algorithm based on HOOM is proposed. The algorithm showed a high sensitivity of (93.33%) and an overall accuracy of (80%) in classifying convulsive PNES.
  • Item
    No Preview Available
    Feasibility of a Chronic, Minimally Invasive Endovascular Neural Interface
    Opie, NL ; Rind, GS ; John, SE ; Ronayne, SM ; Grayden, DB ; Burkitt, AN ; May, CN ; O'Brien, TJ ; Oxley, TJ ; Patton, J ; Barbieri, R ; Ji, J ; Jabbari, E ; Dokos, S ; Mukkamala, R ; Guiraud, D ; Jovanov, E ; Dhaher, Y ; Panescu, D ; Vangils, M ; Wheeler, B ; Dhawan, AP (IEEE, 2016)
    Development of a neural interface that can be implanted without risky, open brain surgery will increase the safety and viability of chronic neural recording arrays. We have developed a minimally invasive surgical procedure and an endovascular electrode-array that can be delivered to overlie the cortex through blood vessels. Here, we describe feasibility of the endovascular interface through electrode viability, recording potential and safety. Electrochemical impedance spectroscopy demonstrated that electrode impedance was stable over 91 days and low frequency phase could be used to infer electrode incorporation into the vessel wall. Baseline neural recording were used to identify the maximum bandwidth of the neural interface, which remained stable around 193 Hz for six months. Cross-sectional areas of the implanted vessels were non-destructively measured using the Australian Synchrotron. There was no case of occlusion observed in any of the implanted animals. This work demonstrates the feasibility of an endovascular neural interface to safely and efficaciously record neural information over a chronic time course.