  • Item
    Thumbnail Image
    Assessment of agreement and interchangeability between the TEG5000 and TEG6S thromboelastography haemostasis analysers: a prospective validation study
    Lloyd-Donald, P ; Churilov, L ; Zia, F ; Bellomo, R ; Hart, G ; McCall, P ; Martensson, J ; Glassford, N ; Weinberg, L (BMC, 2019-03-30)
    BACKGROUND: TEG6S® and TEG5000® (Haemonetics Corp, USA) are haemostasis analysers that measure viscoelasticity properties of whole blood. Both use different mechanisms to assess similar components of the coagulation process. The aim of this study was to assess agreement and interchangeability between the TEG6S and TEG5000 analysers. METHODS: 3.5 mL whole blood was collected from 25 adult patients in a tertiary intensive care unit (ICU). Analysis was performed using TEG6S and TEG5000 haemostatic platforms. Agreement between platforms was measured using Lin's concordance coefficient (Lin's CC), further validated using intraclass correlation coefficients and reduced major axis regression (RMAR). RESULTS: Sixteen (64%) patients were male; mean (range) age: 59yo (23-86). TEG6S and TEG5000 systems were broadly interchangeable. The majority of TEG variables demonstrated almost perfect or substantial agreement and minimal proportional bias (maximum amplitude demonstrated a fixed bias). LY30%, however, demonstrated poor agreement and a proportional bias. Lin's CC coefficients (95% CI, RMAR slope, intercept) between TEG6S and TEG5000 variables were: R time: 0.78 (0.64-0.92, 0.76, 0.92); K time: 0.82 (0.69-0.94, 1.30, - 0.93); alpha angle: 0.79 (0.64-0.95, 1.04, - 1.43); maximum amplitude (MA): 0.90 (0.83-0.96, 0.99, - 5.0); LY30%: 0.34 (0.1-0.58, 0.43, 0.04). CONCLUSIONS: Adult patients with critical illness demonstrate almost perfect agreement in the R time and MA, substantial agreement in K time and alpha angle, but poor agreement in LY30%, as measured by the TEG6S and TEG5000 analysers. With the exception of LY30%, the TEG6S and TEG5000 platforms appear interchangeable. This has important implications for use in clinical practice and multi-site research programs. TRIAL REGISTRATION: ANZCRT number: 12617000062325 , registered 12/Jan17. Retrospectively registered.
  • Item
    Thumbnail Image
    Assessing TEG6S reliability between devices and across multiple time points: A prospective thromboelastography validation study
    Lloyd-Donald, P ; Churilov, L ; Cheong, B ; Bellomo, R ; McCall, PR ; Martensson, J ; Glassford, N ; Weinberg, L (NATURE PORTFOLIO, 2020-04-27)
    The TEG6S is a novel haemostasis analyser utilising resonance technology. It offers potentially greater coagulation information and ease of use, however has not been independently validated in a clinical setting. We aimed to determine if the TEG6S is reliable between devices and across time points. We performed a prospective observational study with ethical approval. For interdevice reliability, we performed simultaneous analysis on two TEG6S devices on 25 adult ICU patients. For time point reliability, we performed repeated sampling across five different time points on 15 adult participants. Blood was collected with informed consent, or as standard care, before four-channel citrated kaolin analysis. We observed almost perfect interdevice reliability across all TEG parameters. The Lin's concordance correlation coefficients (95% CI, major axis regression slope, intercept) were R-time: 0.96 (0.92-0.99, 0.88, 0.57); K-time: 0.93 (0.87-0.98, 1.07, 0.00); Alpha Angle: 0.87 (0.78-0.96, 1.20, -14.10); Maximum Amplitude: 0.99 (0.98-0.99, 1.02, -1.38); Clot Lysis: 0.89 (0.82-0.97, 1.20, 0.07). Additionally, we observed moderate-to-high reliability across time points. Demonstrating almost perfect agreement across different devices and moderate-to-high reliability across multiple time points, suggests the TEG6S platform can be used with haemostatic accuracy and generalisability. This has potentially significant implications for clinical practice and multi-site research programs.