Medicine (Austin & Northern Health) - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    Assessing TEG6S reliability between devices and across multiple time points: A prospective thromboelastography validation study
    Lloyd-Donald, P ; Churilov, L ; Cheong, B ; Bellomo, R ; McCall, PR ; Martensson, J ; Glassford, N ; Weinberg, L (NATURE PORTFOLIO, 2020-04-27)
    The TEG6S is a novel haemostasis analyser utilising resonance technology. It offers potentially greater coagulation information and ease of use, however has not been independently validated in a clinical setting. We aimed to determine if the TEG6S is reliable between devices and across time points. We performed a prospective observational study with ethical approval. For interdevice reliability, we performed simultaneous analysis on two TEG6S devices on 25 adult ICU patients. For time point reliability, we performed repeated sampling across five different time points on 15 adult participants. Blood was collected with informed consent, or as standard care, before four-channel citrated kaolin analysis. We observed almost perfect interdevice reliability across all TEG parameters. The Lin's concordance correlation coefficients (95% CI, major axis regression slope, intercept) were R-time: 0.96 (0.92-0.99, 0.88, 0.57); K-time: 0.93 (0.87-0.98, 1.07, 0.00); Alpha Angle: 0.87 (0.78-0.96, 1.20, -14.10); Maximum Amplitude: 0.99 (0.98-0.99, 1.02, -1.38); Clot Lysis: 0.89 (0.82-0.97, 1.20, 0.07). Additionally, we observed moderate-to-high reliability across time points. Demonstrating almost perfect agreement across different devices and moderate-to-high reliability across multiple time points, suggests the TEG6S platform can be used with haemostatic accuracy and generalisability. This has potentially significant implications for clinical practice and multi-site research programs.
  • Item
    Thumbnail Image
    Comparison of Thromboelastography and Conventional Coagulation Tests in Patients With Severe Liver Disease
    Lloyd-Donald, P ; Vasudevan, A ; Angus, P ; Gow, P ; Martensson, J ; Glassford, N ; Eastwood, GM ; Hart, GK ; Jones, D ; Weinberg, L ; Bellomo, R (SAGE PUBLICATIONS INC, 2020-06-03)
    OBJECTIVE: Thromboelastography (TEG) may provide rapid and clinically important coagulation information in acutely ill patients with chronic liver disease (CLD). Our objective was to describe the relationship between TEG and conventional coagulation tests (CCTs), which has not been previously explored in this population. METHODS: In acutely ill patients with severe CLD (Child-Pugh score > 9, category C), we conducted a prospective observational study investigating coagulation assessment as measured by both CCTs and TEG. We used quantile regression to explore 30 associations between TEG parameters and corresponding CCTs. We compared TEG and CCT measures of coagulation initiation, clot formation, clot strength, and fibrinolysis. RESULTS: We studied 34 patients on a total of 109 occasions. We observed inconsistent associations between TEG and CCT measures of coagulation initiation: TEG (citrated kaolin [CK] assay) standard reaction time and international normalized ratio: R 2 = 0.117 (P = .044). Conversely, there were strong and consistent associations between tests of clot formation: TEG (CK) kinetics time and fibrinogen: R 2 = 0.202 (P < .0001) and TEG (CK) α angle and fibrinogen 0.263 (P < .0001). We also observed strong associations between tests of clot strength, specifically TEG MA and conventional fibrinogen levels, across all TEG assays: MA (CK) and fibrinogen: R 2 = 0.485 (P < .0001). There were no associations between TEG and D-dimer levels. CONCLUSIONS: In acutely ill patients with CLD, there are strong and consistent associations between TEG measures of clot formation and clot strength and conventional fibrinogen levels. There are weak and/or inconsistent associations between TEG and all other conventional measures of coagulation.