Clinical Pathology - Research Publications

Permanent URI for this collection

Search Results

Now showing 1 - 2 of 2
  • Item
    Thumbnail Image
    THE DETECTION OF AXILLARY LYMPH-NODE METASTASES FROM BREAST-CANCER BY RADIOLABELED MONOCLONAL-ANTIBODIES - A PROSPECTIVE-STUDY
    TJANDRA, JJ ; SACKS, NPM ; THOMPSON, CH ; LEYDEN, MJ ; STACKER, SA ; LICHTENSTEIN, M ; RUSSELL, IS ; COLLINS, JP ; ANDREWS, JT ; PIETERSZ, GA ; MCKENZIE, IFC (SPRINGERNATURE, 1989-02)
    In a prospective study to assess the accuracy of monoclonal immunoscintigraphy for the detection of axillary lymph node metastases in breast cancer, two murine monoclonal antibodies that react with human breast cancer (3E1.2 and RCC-1) were labelled with 131iodine, and the radiolabelled antibody was injected subcutaneously into the interdigital spaces of both hands of 40 patients, 36 of whom had breast cancer and the remaining four of whom had fibroadenoma (the normal, contralateral axilla was used as a control). Of the patients with breast cancer, the findings from the scintigraphy images were correlated with histopathology or cytology of the axillary lymph nodes; images were regarded as positive and hence indicative of lymph node metastases if the amount of background-subtracted radioactive count in axilla on the side of breast cancer exceeded the contralateral normal side by a ratio greater than or equal to 1.5:1.0 as assessed by computer analysis. Using this method, immunoscintigraphy had an overall sensitivity of 33% (23% with 131I-3E1.2 and 50% with 131I-RCC-1) for the detection of lymph node metastases and a specificity of 63% (67% with 131I-3E1.2 and 60% with 131I-RCC-1) with problems of non-specific uptake by presumably normal lymph nodes. The results of immunoscintigraphy obtained with 131I-RCC-1 (IgG) were superior to 131I-3E1.2 (IgM) although the accuracy of immunoscintigraphy using 131I-RCC-1 (56%) was not much better than preoperative clinical assessment (50%). However, there were cases when immunoscintigraphy using radiolabelled antibody (IgM or IgG) detected axillary lymph node metastases not suspected by clinical examination. Thus it appears that while immunoscintigraphy may be a useful adjunct to preoperative clinical assessment and is simple and safe, a major improvement in its accuracy is needed before it can replace axillary dissection and histological examination in the accurate staging of axilla in breast cancer.
  • Item
    Thumbnail Image
    CELLS MEDIATING GRAFT-REJECTION IN THE MOUSE .1. LYT-1-CELLS MEDIATE SKIN-GRAFT REJECTION
    LOVELAND, BE ; HOGARTH, PM ; CEREDIG, R ; MCKENZIE, IFC (ROCKEFELLER UNIV PRESS, 1981)
    The Ly phenotype of cells mediating skin graft rejection was determined using monoclonal anti-Lyt-1.1 and Lyt-2.1 antibodies in CBA mice that received CBA lymphoid cells from mice sensitized to C57BL/6; i.e., alloantigenic differences arising from the H-2 and non-H-2 loci. It was clear that graft rejection was due wholly to the presence of Lyt-1 cells in the inoculum and that Lyt-123 or Lyt-23 cells had no effect. Furthermore, no synergism was noted between Lyt-1 and Lyt-2 cells. In this model, both the cytotoxic T cell and cytotoxic lymphocyte precursors were shown to be Lyt-123 and these could be depleted from sensitized Lyt-1 populations that mediated graft rejection. Thus cytotoxic T cells are not responsible for skin graft rejection, but rather, this is mediated by an Lyt-1 cell. Whether this T cell is distinct from other Lyt-1 cells (T helper, T cells mediating delayed hypersensitivity) is not clear at present, but other evidence, and traditional concepts, link graft rejection and delayed type hypersensitivity as being different manifestations of the same mechanism.