Midbrain responses to micro-stimulation of the cochlea using high density thin-film arrays

Loading...
Thumbnail Image
Citations
Web of Science:
Scopus:
Altmetric:
Altmetric::
Download
Associated Records
File Licence
Editors
Date
2012-05-01
Source Title
Hearing Research
Journal Title
Journal ISSN
Volume Title
Publisher
ELSEVIER SCIENCE BV
Affiliation
Document Type
Journal Article
Subject Code
Citation
Allitt, B. J., Morgan, S. J., Bell, S., Nayagam, D. A. X., Arhatari, B., Clark, G. M. & Paolini, A. G. (2012). Midbrain responses to micro-stimulation of the cochlea using high density thin-film arrays. Hearing Research, 287 (1-2), pp.30-42. https://doi.org/10.1016/j.heares.2012.04.004.
Access Status
This item is currently not available from this repository
Access URL
Open Access URL
Open Access at PMC
Linked Resource URL
NHMRC Grant Code
ARC Grant Code
Description
Abstract
A broader activation of auditory nerve fibres than normal using a cochlear implant contributes to poor frequency discrimination. As cochlear implants also deliver a restricted dynamic range, this hinders the ability to segregate sound sources. Better frequency coding and control over amplitude may be achieved by limiting current spread during electrical stimulation of the cochlea and positioning electrodes closer to the modiolus. Thin-film high density microelectrode arrays and conventional platinum ring electrode arrays were used to stimulate the cochlea of urethane-anaesthetized rats and responses compared. Neurophysiological recordings were taken at 197 multi-unit clusters in the central nucleus of the inferior colliculus (CIC), a site that receives direct monaural innervation from the cochlear nucleus. CIC responses to both the platinum ring and high density electrodes were recorded and differences in activity to changes in stimulation intensity, thresholds and frequency coding of neural activation were examined. The high density electrode array elicited less CIC activity at nonspecific frequency regions than the platinum ring electrode array. The high density electrode array produced significantly lower thresholds and larger dynamic ranges than the platinum ring electrode array when positioned close to the modiolus. These results suggest that a higher density of stimulation sites on electrodes that effectively 'aim' current, combined with placement closer to the modiolus would permit finer control over charge delivery. This may equate to improved frequency specific perception and control over amplitude when using future cochlear implant devices.
Notes
Terms of Use
Keywords
auditory nerve fibres, cochlear implant, frequency discrimination, dynamic range, amplitude control, electrical stimulation, cochlea, electrodes, modiolus, microelectrode arrays, neurophysiological recordings, central nucleus, inferior colliculus, monaural innervations, charge delivery, frequency specific perception
Publisher Licence