Uptake, Persistence, and Performance of Weekly Home Monitoring of Visual Field in a Large Cohort of Patients With Glaucoma

Loading...
Thumbnail Image
Citations
Web of Science:
Scopus:
Altmetric:
Altmetric::
Associated Records
File Licence
Editors
Date
2021-03-01
Source Title
American Journal of Ophthalmology
Journal Title
Journal ISSN
Volume Title
Publisher
ELSEVIER SCIENCE INC
Affiliation
Ophthalmology (Eye & Ear Hospital)
Optometry and Vision Sciences
Document Type
Journal Article
Subject Code
Citation
Prea, S. M., Kong, G. Y. X., Guymer, R. H. & Vingrys, A. J. (2021). Uptake, Persistence, and Performance of Weekly Home Monitoring of Visual Field in a Large Cohort of Patients With Glaucoma. American Journal of Ophthalmology, 223, pp.286-295. https://doi.org/10.1016/j.ajo.2020.10.023.
Access Status
Open Access
Access URL
Open Access URL
Open Access at PMC
Linked Resource URL
NHMRC Grant Code
ARC Grant Code
Description
Abstract
PURPOSE: This study examines the short-term uptake, compliance, and performance of a tablet device used for home monitoring of visual field (VF-Home) by glaucoma patients. DESIGN: Single-center, observational, longitudinal, compliance study. METHODS: Participants who were glaucoma suspects or had stable glaucoma in at least one eye were recruited during a regular clinic review. Baseline in-clinic visual field (VF) was recorded with the Humphrey Field Analyser (HFA, SITA standard) and repeated at 6 months. Participants were tasked with performing 6 VF examinations from home, at weekly intervals, using a loaned iPad tablet. Uptake was defined as returning at least 1 test from home. Reliability and global indices from VF-Home were compared to in-clinic outcomes. Data are shown as either mean ± [standard deviation] or median [quartile 1-3 range], and group comparisons were achieved with bootstrap. RESULTS: We recruited 186 eyes of 101 participants. VF-Home uptake was excellent, with 88% of participants successfully completing ≥1 home examination and 69% completing all 6 examinations. The median duration between tests was 7.0 [7.0-8.0] days. Barriers to uptake and compliance involved information technology (IT) logistical reasons, lack of motivation, or competing life demands. VF-Home gave greater fixation loss but a similar level of False Positives (FP) as the HFA. A high correlation was found for the mean defect between in-clinic and at-home outcomes (R = 0.85). CONCLUSIONS: VF-Home can return a high level of short-term compliance and results comparable to those found by in-clinic testing. IT logistical reasons and lack of motivation are barriers to uptake and compliance.
Notes
Terms of Use
Keywords
Publisher Licence