Radiomics and Machine Learning with Multiparametric Breast MRI for Improved Diagnostic Accuracy in Breast Cancer Diagnosis.

Loading...
Thumbnail Image
Citations
Altmetric:
Altmetric::
Associated Records
File Licence
Editors
Date
2021-05-21
Source Title
Diagnostics
Journal Title
Journal ISSN
Volume Title
Publisher
MDPI AG
Melbourne Authors
Affiliation
Surgery (RMH)
Document Type
Journal Article
Subject Code
Citation
Daimiel Naranjo, I., Gibbs, P., Reiner, J. S., Lo Gullo, R., Sooknanan, C., Thakur, S. B., Jochelson, M. S., Sevilimedu, V., Morris, E. A., Baltzer, P. A. T., Helbich, T. H. & Pinker, K. (2021). Radiomics and Machine Learning with Multiparametric Breast MRI for Improved Diagnostic Accuracy in Breast Cancer Diagnosis.. Diagnostics (Basel), 11 (6), pp.919-. https://doi.org/10.3390/diagnostics11060919.
Access Status
Open Access
Access URL
Open Access URL
Linked Resource URL
NHMRC Grant Code
ARC Grant Code
Description
Abstract
The purpose of this multicenter retrospective study was to evaluate radiomics analysis coupled with machine learning (ML) of dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) radiomics models separately and combined as multiparametric MRI for improved breast cancer detection. Consecutive patients (Memorial Sloan Kettering Cancer Center, January 2018-March 2020; Medical University Vienna, from January 2011-August 2014) with a suspicious enhancing breast tumor on breast MRI categorized as BI-RADS 4 and who subsequently underwent image-guided biopsy were included. In 93 patients (mean age: 49 years ± 12 years; 100% women), there were 104 lesions (mean size: 22.8 mm; range: 7-99 mm), 46 malignant and 58 benign. Radiomics features were calculated. Subsequently, the five most significant features were fitted into multivariable modeling to produce a robust ML model for discriminating between benign and malignant lesions. A medium Gaussian support vector machine (SVM) model with five-fold cross validation was developed for each modality. A model based on DWI-extracted features achieved an AUC of 0.79 (95% CI: 0.70-0.88), whereas a model based on DCE-extracted features yielded an AUC of 0.83 (95% CI: 0.75-0.91). A multiparametric radiomics model combining DCE- and DWI-extracted features showed the best AUC (0.85; 95% CI: 0.77-0.92) and diagnostic accuracy (81.7%; 95% CI: 73.0-88.6). In conclusion, radiomics analysis coupled with ML of multiparametric MRI allows an improved evaluation of suspicious enhancing breast tumors recommended for biopsy on clinical breast MRI, facilitating accurate breast cancer diagnosis while reducing unnecessary benign breast biopsies.
Notes
Terms of Use
Keywords
Publisher Licence